32,731 results match your criteria: "and Altman; and Maria Fareri Children's Hospital at Westchester Medical Center[Affiliation]"

Enhanced prediction of partial nitrification-anammox process in wastewater treatment by developing an attention-based deep learning network.

J Environ Manage

January 2025

School of Artificial Intelligence, Xidian University, No. 2 South Taibai Road, Xi'an, Shaanxi, 710071, China.

In the process of partial nitrification and anaerobic ammonia oxidation (anammox) for nitrogen removal, the process offers simple metabolic pathways, low operating costs, and high nitrogenous loading rates. However, since the partial nitrification-anammox (PN-anammox) process combines partial nitrification and anammox reactions within the same reactor, strict control of dissolved oxygen (DO) is essential. Additionally, assessing treatment performance through chemical measurement involves time lag, making it challenging to recover the biological process when issue arise, especially in the PN-anammox process, where strict DO control and the sensitivity of anammox bacteria to conditions and substrates demand timely intervention.

View Article and Find Full Text PDF

Objective: To assess the agreement of transpulmonary thermodilution (TPTD) and transpulmonary ultrasound dilution (TPUD) against direct measurement of main pulmonary artery flow with an ultrasound transit time flow probe (UTF) over a wide range of conditions in anesthetized cats. Additionally, the trending ability of TPTD, TPUD, and esophageal Doppler ultrasonography (EDU) was evaluated against UTF.

Methods: 12 purpose-bred cats were used.

View Article and Find Full Text PDF

A convenient but efficient tool for evaluating dietary intakes in Chinese professional athletes has yet to be established. The aim of this study was to assess the validity of a short semi-quantitative food frequency questionnaire (FFQ) through comparison with 3-day weighed food records (3DWFRs) and corresponding serum biomarkers from a cohort of 102 professional athletes, while also evaluating its reproducibility. The relative validity was assessed using Spearman correlation coefficients, cross-quintiles classification, weighted kappa, and Bland-Altman analysis, while reproducibility was evaluated using the Spearman correlation coefficients and intraclass correlation coefficient (ICC) between two FFQs.

View Article and Find Full Text PDF

Introduction: Measurement of repeatability and reproducibility (R&R) is necessary to realize the full potential of positron emission tomography (PET). Several studies have evaluated the reproducibility of PET using 18F-FDG, the most common PET tracer used in oncology, but similar studies using other PET tracers are scarce. Even fewer assess agreement and R&R with statistical methods designed explicitly for the task.

View Article and Find Full Text PDF

Background And Purpose:  Computed tomography radiostereometric analysis (CT-RSA) assesses implant micromovements using low-dose CT scans. We aimed to investigate whether CT-RSA is comparable to marker-based radiostereometric analysis (RSA) measuring early femoral head migration in cemented stems. We hypothesized that CT-RSA is comparable to marker-based RSA in evaluating femoral head subsidence.

View Article and Find Full Text PDF

Background And Purpose:  Degenerative cervical myelopathy (DCM) is the most common cause of spinal cord dysfunction in adults. Repeated follow-ups after surgery are resource consuming. The aim was to examine whether patient-reported outcome measures (PROMs) change after the first year.

View Article and Find Full Text PDF

The Patient-Rated Wrist and Hand Evaluation is an outcome measure for patients with conditions affecting the wrist or hand. We evaluated the structural validity of the Patient-Rated Wrist and Hand Evaluation using psychometric techniques, then developed computerized adaptive testing algorithms. Factor analysis found two health constructs consistent with 'Pain' and 'Motor Function'.

View Article and Find Full Text PDF

Objectives: To compare a new ready-to-use monotest immunoassay, CHORUS Promonitor, for the quantification of serum biological drug levels and anti-drug antibodies of anti-TNF agents, against the reference batch-based ELISA test, Promonitor.

Methods: Blood samples were collected from patients treated with anti-TNF agents, infliximab (IFX) or adalimumab (ADL). IFX and ADL levels, as well as anti-IFX and anti-ADL antibodies were quantified and compared between the standard ELISA reference test, Promonitor, and the automated monotest ELISA assay, CHORUS Promonitor.

View Article and Find Full Text PDF

Background: Luminal and hemodynamic evaluations of the cervical arteries inform the diagnosis and management of patients with cervical arterial disease.

Purpose: To demonstrate a 3D nonenhanced quantitative quiescent interval slice-selective (qQISS) magnetic resonance angiographic (MRA) strategy that provides simultaneous hemodynamic and luminal evaluation of the cervical arteries.

Study Type: Prospective.

View Article and Find Full Text PDF

Evaluation of a point-of-care test for quantitative determination of total thyroxine in feline serum.

J Feline Med Surg

January 2025

Department of Veterinary Medicine and Animal Sciences (DIVAS), University of Milan, Lodi (LO), Italy.

Objectives: Total thyroxine (TT4) evaluation is the most commonly used first-line test for the diagnosis and monitoring of cats with hyperthyroidism. Vcheck T4 is a point-of-care immunoassay that measures TT4 using a Vcheck V200 analyser. This study aimed to evaluate the analytic performance of the Vcheck T4 assay in feline sera and the agreement in the classification of normal, high and low TT4 concentrations of Vcheck T4 with those measured by an enzyme immunoassay (EIA).

View Article and Find Full Text PDF

Objectives: Dual energy x-ray absorptiometry (DXA) provides incomplete information about bone strength. There are few data on the relationship between osteoporosis-related examinations and bone strength. The objective of the present study was to determine which osteoporosis-related examinations best predicted trabecular bone strength, and to enhance a formula for predicting bone strength on the basis of bone density examination.

View Article and Find Full Text PDF

Objective: To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI.

Materials And Methods: This study included 150 participants (51 male; mean age 57.3 ± 16.

View Article and Find Full Text PDF

Background: Adjusting dietary potassium intake based on 24-hour urinary potassium excretion is the primary method of preventing hyperkalemia. Currently, there is no accurate and convenient method for calculating maximum 24-hour urinary potassium excretion in kidney failure without replacement therapy patients. We developed and validated two new models to assess the upper limit of dietary potassium consumption in this high-risk cohort, using the maximum 24-hour urinary potassium excretion as a proxy.

View Article and Find Full Text PDF

Whilst improving hygiene and sanitation behaviours is key to cost-effective and sustainable water, sanitation and hygiene interventions, measuring behaviour change remains a challenge. This study assessed the validity and reliability of pictorial 24-h recall (P24 hR), a novel method using unprompted recall of past activities through pictures, compared to structured observation for measuring handwashing with soap (HWWS) and safe child faeces disposal in rural Malawi. Data were collected from 88 individuals across 74 households in Chiradzulu district using both methods over a two-day period, with the recall period of the P24 hR corresponding to the period of structured observation completed the previous day.

View Article and Find Full Text PDF

Purpose: To investigate the performance of a machine learning-based segmentation method for treatment planning of gastric cancer.

Materials And Methods: Eighteen patients planned to be irradiated for gastric cancer were studied. The target and the surrounding organs-at-risk (OARs) were manually delineated on CT scans.

View Article and Find Full Text PDF

Objective: To explore the feasibility of post-exercise heart rate recovery indicators for predicting maximum oxygen uptake (VO2max) in healthy adults aged 30-60 years.

Methods: 260 healthy adults who did not perform regular exercise were randomly recruited and divided into a model group (n = 200) and a verification group (n = 60). Measure body fat percentage, weight, height and other indicators, and complete a cardiopulmonary exercise test as required to measure VO2max and heart rate recovery (HRR1, HRR2) in the first and second minutes after exercise.

View Article and Find Full Text PDF

Background: Studies on the accuracy of point-of-care (POC) testing using capillary samples are scarce. Therefore, this study aimed to assess the analytical accuracy of POC testing for white blood cell (WBC) and C-reactive protein (CRP) using capillary samples compared with conventional central laboratory testing using venous samples in a pediatric ambulatory care setting.

Methods: This was a retrospective study including patients younger than 18 years who underwent concurrent WBC and CRP evaluations via capillary and subsequent venous sampling within a 2-h window.

View Article and Find Full Text PDF

Introduction And Hypothesis: The aim of the study was to compare clinical outcomes when using robotic-assisted sacral hysterocolpopexy (RASC) and vaginal surgery using the Uphold™ Vaginal Support System mesh for pelvic organ prolapse repair.

Methods: This was a nonrandomized, prospective, multicenter study in which 72 women underwent RASC, and 73 Uphold™ surgery, for apical prolapse (POP-Q C ≥ stage II). Anatomical outcomes were assessed using the Pelvic Organ Prolapse Quantification (POP-Q) system.

View Article and Find Full Text PDF

Machine Learning for Automated Identification of Anatomical Landmarks in Ultrasound Periodontal Imaging.

Dentomaxillofac Radiol

January 2025

Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, USA.

Objectives: To identify landmarks in ultrasound periodontal images and automate the image-based measurements of gingival recession (iGR), gingival height (iGH), and alveolar bone level (iABL) using machine learning.

Methods: We imaged 184 teeth from 29 human subjects. The dataset included 1580 frames for training and validating the U-Net CNN machine learning model, and 250 frames from new teeth that were not used in training for testing the generalization performance.

View Article and Find Full Text PDF

Introduction: The ActiGraph (AG) accelerometer is widely used to assess physical activity (PA) in heart failure (HF) patients. However, the validity of the AG in this population remains unexplored.

Objective: Therefore, this study examined the criterion validity of the AG-GT9X for measuring step counts (SC) and energy expenditure (EE) among HF patients.

View Article and Find Full Text PDF

Automated craniofacial biometry with 3D T2w fetal MRI.

PLOS Digit Health

December 2024

Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, United Kingdom.

Objectives: Evaluating craniofacial phenotype-genotype correlations prenatally is increasingly important; however, it is subjective and challenging with 3D ultrasound. We developed an automated label propagation pipeline using 3D motion- corrected, slice-to-volume reconstructed (SVR) fetal MRI for craniofacial measurements.

Methods: A literature review and expert consensus identified 31 craniofacial biometrics for fetal MRI.

View Article and Find Full Text PDF

Background: Precise functional capacity assessment is a critical component for preoperative risk stratification. Brief submaximal cardiopulmonary exercise testing (smCPET) has shown diagnostic utility in various cardiopulmonary conditions. Objective: The objective of this study was to determine if smCPET could be implemented in a high-volume pre-surgical evaluation clinic, and, when compared to structured functional capacity surveys, if smCPET could better discriminate low functional capacity (<4.

View Article and Find Full Text PDF

In digital image diagnosis using medical displays, it is crucial to rigorously manage display devices to ensure appropriate image quality and diagnostic safety. The aim of this study was to develop a model for the efficient quality control (QC) of medical displays, specifically addressing the measurement items of contrast response and maximum luminance as part of constancy testing, and to evaluate its performance. In addition, the study focused on whether these tasks could be addressed using a multitasking strategy.

View Article and Find Full Text PDF

The study sought to compare the number of cycles (NOS) for the first and second thirty-seconds (FASTS) within 1 min of accommodative facility (AF) and vergence facility (VF) testing to explore possibilities of reducing testing time to 30 s. In this cross-sectional study, a multistage sample of school children (aged 8-17 years) was taken through ocular-visual screening. Eligible participants (586) underwent refraction, stereo-acuity measurement, AF testing using ± 2D lens flippers, and VF testing using 3 BI/12 BO flipper prisms.

View Article and Find Full Text PDF

Purpose: Emoji are digital images or icons used to express an idea or emotion in electronic communication. The purpose of this study was to develop and evaluate the psychometric properties of two patient-reported scales that incorporate emoji.

Methods: The Emoji Response Scale developed for this study has two parts: the Emoji-Ordinal and Emoji-Mood scales.

View Article and Find Full Text PDF