213 results match your criteria: "Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel.[Affiliation]"

Aims: Cavotricuspid isthmus (CTI) ablation is the current ablation treatment for typical atrial flutter (AFL). However, post-ablation atrial tachyarrhythmias, mostly in the form of atrial fibrillation (AF), are frequently observed after CTI ablation. We aimed to evaluate the effectiveness and safety of concomitant or isolated pulmonary vein isolation (PVI) in patients with typical AFL scheduled for ablation.

View Article and Find Full Text PDF

Pentaspline catheter or cryoballoon for pulmonary vein plus posterior wall isolation in persistent atrial fibrillation: 1-Year outcomes.

Heart Rhythm

December 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium. Electronic address:

Background: Left atrial posterior wall isolation (LAPWI) plus pulmonary vein isolation (PVI) can be performed with radiofrequency ablation, cryoballoon ablation (CB-A), or, recently, pulsed field ablation (PFA).

Objective: The aims of this study were to evaluate efficacy and safety of the pentaspline PFA catheter for PVI + LAPWI in patients with persistent AF undergoing an index ablation procedure and to compare 1-year outcomes of PVI + LAPWI with PFA vs CB-A.

Methods: All consecutive patients undergoing an index ablation for persistent atrial fibrillation (AF) at Universitair Ziekenhuis Brussel, Belgium, between 2021 and 2023 were retrospectively screened.

View Article and Find Full Text PDF

Background: A novel focal lattice-tip catheter allowing the delivery of either pulsed field (PF) or radiofrequency (RF) energy has recently received regulatory approval. The technology features a proprietary 3-dimensional electroanatomic mapping system.

Objective: We describe the first real-world and multicenter experience.

View Article and Find Full Text PDF

Background: Electrical remodeling has been linked to the progression and recurrence of atrial fibrillation (AF) after catheter ablation (CA). Substrate mapping based solely on a voltage amplitude electrogram (EGM) does not provide a comprehensive understanding of the left atrial (LA) disease. The aim of this study is to assess left atrial spatial entropy (LASE) from voltage maps routinely obtained during AF ablation to further characterize the LA substrate.

View Article and Find Full Text PDF

A 53-year-old woman was hospitalized due to a fever of unknown origin for three weeks. Given the presence of fever and fatigue, the laboratory findings, and a bone marrow biopsy confirming hemophagocytic lymphohistiocytosis (HLH), a hematological malignancy was suspected. Peripheral lymphocytic typing, bone marrow biopsy, and imaging could not identify an underlying cause of HLH.

View Article and Find Full Text PDF

In Vivo Mapping of Human Ventricular Fibrillation in Brugada Syndrome: The Role of Repolarization Heterogeneity.

Circ Arrhythm Electrophysiol

December 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, European Reference Networks Guard-Heart (L.P., D.G.D.R., P.V., A. Sorgente, A.D.M., G.V., M.C.F., G.T., I.E., P.-A.C., I.O., G.B., A.A., E.S., G.P., J.S., A.G., P.B., G.B.C., A. Sarkozy, C.d.A.), Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Belgium.

Article Synopsis
  • Brugada syndrome (BrS) is linked to dangerous heart rhythms called ventricular fibrillation (VF), and this study explores VF mapping using ECG imaging to understand the relationship between different VF mechanisms.* -
  • The researchers focused on patients diagnosed with BrS who experienced VF during a specific heart procedure, analyzing various heart rhythm maps to identify spatial correlations between repolarization gradients and VF triggers.* -
  • Results showed that most BrS patients had distinct "repolarization cliffs" that initiated VF, suggesting these cliffs could be important targets for treatment to prevent VF recurrence.*
View Article and Find Full Text PDF
Article Synopsis
  • Pulsed field ablation (PFA) is a new treatment for atrial fibrillation (AF) that shows strong safety and efficacy by specifically targeting heart muscle cells while sparing nearby tissues.
  • A meta-analysis comparing PFA with cryoballoon ablation (CRYO) found that PFA had higher procedural success rates and fewer complications, along with shorter procedural and fluoroscopy times.
  • However, there were no significant differences in major complications or freedom from atrial tachyarrhythmias after one year between the two techniques.
View Article and Find Full Text PDF

Safety and Feasibility of Pulsed Field Ablation in Patients With Mechanical Prosthetic Valves.

JACC Clin Electrophysiol

November 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.

Article Synopsis
  • Pulsed field ablation (PFA) is a new technique for heart tissue treatment that targets heart cells directly without damaging nearby tissues, but using it with mechanical heart valves can be tricky due to potential interference.* -
  • This study involved 30 patients with mechanical heart valves undergoing PFA for atrial fibrillation, and it found no major complications, with normal valve function post-procedure.* -
  • While PFA seems safe for patients with mechanical valves, careful management of the catheter is crucial to prevent electromagnetic interference that could affect the treatment.*
View Article and Find Full Text PDF

Background: Speckle tracking echocardiography (STE) provides quantification of left ventricular (LV) deformation and is useful in the assessment of LV function. STE is increasingly being used clinically, and every effort to simplify and standardize STE is important. Manual outlining of regions of interest (ROIs) is labor intensive and may influence assessment of strain values.

View Article and Find Full Text PDF

aTrial arrhythmias in inhEriTed aRrhythmIa Syndromes: results from the TETRIS study.

Europace

December 2024

Division of Cardiology, Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Via Tesserete 48, CH-6900 Lugano, Switzerland.

Article Synopsis
  • * AAs were the first symptom of IAS in 52% of patients, and nearly a quarter had multiple AAs documented.
  • * The study found a moderate incidence of severe outcomes, including a yearly primary endpoint rate of 1.4%, with younger patients experiencing higher risks and other complications affecting some patients as well.
View Article and Find Full Text PDF
Article Synopsis
  • The peQasus study evaluates the safety and effectiveness of a new temperature-controlled high-power short-duration (HPSD) radiofrequency catheter (QDOT Micro) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF).
  • Conducted across 15 centers in Europe, the study involved 1,023 patients and compared outcomes between a very HPSD technique and a hybrid approach.
  • Results indicated complete PVI success, a mean procedure time of about 98 minutes, and a similar safety profile for both techniques, with 12-month arrhythmia-free survival rates around 77%.
View Article and Find Full Text PDF

Ultrasound-guided versus fluoroscopy-guided axillary vein puncture for cardiac implantable electronic device implantation: a meta-analysis enrolling 1257 patients.

J Interv Card Electrophysiol

October 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.

Introduction: Ultrasound-guided (Echo-AVP) and Fluoroscopy-guided Axillary Vein Puncture (Fluoro-AVP) are both acknowledged as safe and effective techniques for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. Therefore, we performed a meta-analysis to evaluate the efficacy and safety of Echo-AVP versus Fluoro-AVP for CIEDs implantation.

View Article and Find Full Text PDF

Multielectrode catheter-based pulsed field ablation of persistent and long-standing persistent atrial fibrillation.

Europace

October 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Av. du Laerbeek 101, 1090 Jette, Brussels, Belgium.

Aims: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF > 6 m) and long-standing persistent AF (LSPAF).

Methods And Results: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3).

View Article and Find Full Text PDF

Ranolazine is an anti-anginal medication that has demonstrated antiarrhythmic properties by inhibiting both late sodium and potassium currents. Studies have shown promising results for ranolazine in treating both atrial fibrillation and ventricular arrhythmias, particularly when used in combination with other medications. This review explores ranolazine's mechanisms of action and its potential role in cardiac arrhythmias treatment in light of previous clinical studies.

View Article and Find Full Text PDF

Aims: Several algorithms can differentiate inferior axis premature ventricular contractions (PVCs) originating from the right side and left side on 12-lead electrocardiograms (ECGs). However, it is unclear whether distinguishing the origin should rely solely on PVC or incorporate sinus rhythm (SR). We compared the dual-rhythm model (incorporating both SR and PVC) to the PVC model (using PVC alone) and quantified the contribution of each ECG lead in predicting the PVC origin for each cardiac rotation.

View Article and Find Full Text PDF

Safety and efficacy of pulsed-field ablation for atrial fibrillation in the elderly: A EU-PORIA sub-analysis.

Int J Cardiol

December 2024

Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France; Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Jette, Brussels, Belgium. Electronic address:

Background: The role of catheter ablation in elderly patients with atrial fibrillation (AF) is unclear. Pulsed field ablation (PFA) demonstrates a favorable clinical profile, however, data on elderly patients are lacking.

Aims: We aimed to assess the safety and efficacy of PFA in the elderly, using data from the EU-PORIA registry.

View Article and Find Full Text PDF

Focal Pulsed Field Ablation for Premature Ventricular Contractions: A Multicenter Experience.

Circ Arrhythm Electrophysiol

September 2024

Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Belgium (D.G.D.R., M.C.-F., L.P., A.A., E.S., G. Bala, J.S., G.V., A. Sorgente, C.A., I.O., A.D.M., G.-B.C., C.d.A., A. Sarkozy).

Background: Pulsed field ablation (PFA) is a novel technology for catheter-based atrial arrhythmia treatment. Evidence of its application for ventricular arrhythmia ablation is still limited. In this study, we describe the feasibility and efficacy of focal PFA for premature ventricular contraction (PVC) ablation.

View Article and Find Full Text PDF

Aims: Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using conventional ablation settings with 20/60 s RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15 s (s) on the posterior wall when facing the oesophageal region is as effective as applying 20 s. To prospectively assess whether reducing RF time on PST/ANT segments to 15/45 s can ensure sufficient quality of lesion metrics and compare the new shortened ablation settings with the conventional one in terms of safety, and effectiveness at 1-year.

View Article and Find Full Text PDF

Continuous Rhythm Monitoring With Implanted Loop Recorders in Children and Adolescents With Brugada Syndrome.

J Am Coll Cardiol

September 2024

Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Lugano, Switzerland; Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland. Electronic address:

Background: Young (<18 years of age) patients with Brugada syndrome (BrS) are often under-represented in BrS studies and their management, especially related to syncopal episodes, remains unclear.

Objectives: This study sought to describe the arrhythmia prevalence among young patients with BrS undergoing continuous rhythm monitoring by implantable loop recorder (ILR) and to assess the etiology behind syncope of undetermined origin.

Methods: A total of 147 patients with BrS with ILR were enrolled in 12 international centers and divided into pediatric (age <12 years; n = 77, 52%) and adolescents (age 13-18 years; n = 70, 48%).

View Article and Find Full Text PDF

Distance-dependent neuromodulation effect during thermal ablation for atrial fibrillation.

J Cardiovasc Electrophysiol

October 2024

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium.

Article Synopsis
  • The study investigates how thermal atrial fibrillation (AF) ablation impacts the cardiac autonomic nervous system (CANS) by focusing on the effects during the ablation of the right superior pulmonary vein (RSPV) and its influence on the heart rate (HR) post-ablation.
  • Researchers evaluated 97 patients undergoing first-time thermal ablation, analyzing HR changes and anatomical factors through pre- and post-procedural electrocardiograms and cardiac CT measurements.
  • Results showed that 38.1% of patients experienced a significant HR increase after the procedure, with key predictors being the distance between the RSPV and superior vena cava (SVC) and the patient's age,
View Article and Find Full Text PDF