57 results match your criteria: "Unigranrio University[Affiliation]"

The aim of this study was to evaluate the in vivo performance of two different deproteinized bovine bone (DBB) grafting materials: DBBB (Bio-Oss®) and DBBL (Laddec®), for the regeneration of critically sized (8 mm) defects in rabbit's calvaria. Three round-shaped defects were surgically created in the calvaria of 13 New Zealand White rabbits proximal to the coronal suture in the parietal bone. Two of the defects were filled with one of the grafting materials while a third was left empty to serve as a negative control.

View Article and Find Full Text PDF

The parasite causes Chagas' disease; both heme and ionic Fe are required for its optimal growth, differentiation, and invasion. Fe is an essential cofactor in many metabolic pathways. Fe is also harmful due to catalyzing the formation of reactive O species; for this reason, all living systems develop mechanisms to control the uptake, metabolism, and storage of Fe.

View Article and Find Full Text PDF

Silane-coating strategy has been used to bind biological compounds to the titanium surface, thereby making implant devices biologically active. However, it has not been determined if the presence of the silane coating itself is biocompatible to osseointegration. The aim of the present study was to evaluate if silane-coating affects bone formation on titanium using a rabbit model.

View Article and Find Full Text PDF

Statement Of Problem: Although luting space is related to the marginal fit of indirect restorations, information on its influence on the marginal fit and tensile strength of zirconia abutments bonded to titanium bases is lacking.

Purpose: The purpose of this in vitro study was to evaluate the influence of luting space on the marginal discrepancy and tensile strength of zirconia abutments bonded to a titanium base after dynamic loading.

Material And Methods: Ninety implant replicas were embedded in resin blocks to attach 4-mm-high titanium luting bases.

View Article and Find Full Text PDF

Atrophic maxilla rehabilitation through dental implants is always a challenging procedure. However, alternative approaches such as guided surgery and the installation of short implants are progressively supplanting more invasive bone regeneration procedures. A V-4 technique described in 2016 facilitates the installation of dental implants in patients with atrophic maxilla; however, its authors recommend incision, flap opening, and elevation of the anterior area of the maxillary sinuses.

View Article and Find Full Text PDF

The ENA ATPases (from : the exit of sodium) belonging to the P-type ATPases are structurally very similar to the sarco/endoplasmic reticulum Ca-ATPase (SERCA); they exchange Na for H and, therefore, are also known as Na-ATPases. ENA ATPases are required in alkaline milieu, as in the case for , where other transporters cannot mediate an uphill Na efflux. They are also important for salt tolerance, as described for .

View Article and Find Full Text PDF

Treatment of Acute Toxoplasmosis in Pregnancy: Influence in the Mother-to-Child Transmission.

J Obstet Gynaecol Can

December 2020

Department of Obstetrics, Paulista School of Medicine-Federal University of São Paulo, São Paulo, Brazil; Municipal University of São Caetano do Sul, Campus Bela Vista, São Paulo, Brazil. Electronic address:

Objective: To evaluate the association between treatment and mother-to-child transmission of acute Toxoplasma gondii infection in pregnancy.

Methods: This was a concurrent cohort study of 26 pregnant women diagnosed with acute toxoplasmosis. Transmission of T.

View Article and Find Full Text PDF

An Comparison of the Forces Released by Closed Nickel-Titanium Springs.

J Contemp Dent Pract

December 2019

Division of Pediatric Dentistry, Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, Brazil, Phone: +55 19 3211-3608, e-mail:

Aim: The aim of this study was to evaluate the force-release behavior of closed coil nickel-titanium springs of three different commercial brands available on the market, as well those from different batches, tested over multiple distances, according to the number of deactivations.

Materials And Methods: For this analysis, closed coil nickel-titanium springs of the following numbers and brands: eight, 3 mm GAC® springs; eight, 3 mm springs from TP Orthodontics® and eight, 5 mm springs from MORELLI® were standardized at 200 gf force. Two batches of all three brands were tested and compared.

View Article and Find Full Text PDF

The structural organization of Giardia intestinalis cytoskeleton.

Adv Parasitol

July 2020

UNIGRANRIO-University of Grande Rio, Rio de Janeiro, Brazil; Biophysics Institute-Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; CENABIO-National Center for Structural Biology and Bioimaging and National Institute of Science and Technology on Structural Biology and Bioimaging, Rio de Janeiro, Brazil. Electronic address:

Giardia intestinalis, the causative agent of giardiasis, has complex cytoskeleton organization with structures involved in motility, adhesion, cell division, and cell differentiation. Microtubules are key components of the cytoskeleton and are the main elements of the ventral disc, median body, funis, in addition to four pairs of flagella. These cytoskeletal elements are basically stable microtubule arrangements.

View Article and Find Full Text PDF

Objectives To evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared with non-activated irrigation (NAI) on periapical healing and root canal disinfection.Data source A comprehensive search without restrictions was performed in the following systematic electronic databases: PubMed, Scopus, Cochrane, Web of Science, ScienceDirect and OpenGrey. Additional studies were sought through hand-searching in the main endodontic journals.

View Article and Find Full Text PDF

A randomized controlled trial was performed to evaluate and compare the changes in implant stability quotient (ISQ) of implants of the same brand, design, length, and diameter but with two different surface treatments, placed in the posterior mandible: sandblasted and acid-etched (SAE) and chemically modified SAE (hydrophilic). Twenty implants of the same design, length, and diameter (cylindrical and compressive, 3.75×11mm) but with different surface treatments (control group: 10 SAE; test group: 10 modified SAE) were randomly assigned to placement in the posterior mandibular region in 20 different patients.

View Article and Find Full Text PDF

Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V).

J Mech Behav Biomed Mater

September 2019

Department of Biomaterials and Biomimetics, New York University, New York, NY, USA; Hansjörg Wyss Department of Plastic Surgery, NYU Langone Health School of Medicine, New York, NY, USA; Mechanical and Aerospace Engineering, NYU Tandon School of Engineering, New York, NY, USA.

This study evaluated the effect of alumina-blasted/acid-etched (AB/AE) or microabrasive blasting (C3-Microblasted) surface treatment on the osseointegration of commercially-pure Ti (grade II) and Ti-6Al-4V alloy (grade V) implants compared to as-machined surfaces. Surface characterization was performed by scanning electron microscopy and optical interferometry (IFM) to determine roughness parameters (Sa and Sq, n = 3 per group). One-hundred forty-four implants were placed in the radii of 12 beagle dogs, for histological (n = 72, bone-to-implant contact - BIC and bone-area-fraction occupancy -BAFO) and torque to interface failure test at 3 and 6 weeks (n = 72).

View Article and Find Full Text PDF

Awareness in Dementia: Development and Evaluation of a Short Version of the Assessment Scale of Psychosocial Impact of the Diagnosis of Dementia (ASPIDD-s) in Brazil.

Alzheimer Dis Assoc Disord

July 2020

Department of Psychology, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil.

Awareness of disease is defined as the recognition of changes caused by the deficits related to the disease process. We aimed to examine the psychometric properties of the short versions of the Assessment Scale of Psychosocial Impact of the Diagnosis of Dementia (ASPIDD-s), a multidimensional awareness scale. Using a cross-sectional design, we included 201 people with dementia and their family caregivers.

View Article and Find Full Text PDF

Synergistic Effects of Implant Macrogeometry and Surface Physicochemical Modifications on Osseointegration: An In Vivo Experimental Study in Sheep.

J Long Term Eff Med Implants

January 2019

Department of Biomaterials and Biomimetics, New York University, New York, NY, USA; Department of Biomedical Engineering, New York University Tandon School of Engineering Brooklyn, New York, NY, USA; Hansjörg Wyss Department of Plastic Surgery, New York University Grossman School of Medicine, New York, NY, USA.

This study evaluates the influence of two surface physicochemical modifications on osseointegration parameters of a healing chamber implant design. We examine dental implants with internal and external trapezoidal threads that have the following surface modifications: dual acid etching (DAE) and nano-hydroxyapatite (HA) coating over DAE surface (Nano). We installed implants in the right ilium of sheep and conducted histologic/metric analyses after 3 and 12 wk in vivo.

View Article and Find Full Text PDF

We evaluate bone remodeling and prostheses survival of immediately provisionalized with occlusal loading and delayed loading (DL) single implants placed in the posterior region after 1-yr follow-up in dental practices. Included in the study are patients selected to receive one regular implant (4 × 10 mm) for single tooth replacement in healed ridge sockets in the mandible and maxilla. Implants are immediately loaded or delayed functionally loaded with metal ceramic crowns, depending on peak insertion torque value.

View Article and Find Full Text PDF

Histological Analysis of an Implant Retrieved from a β-Tricalcium Phosphate Graft after 4 Years: A Case Study.

J Long Term Eff Med Implants

October 2020

Unigranrio University, School of Heath Sciences, Duque De Caxias, Rio De Janeiro; Department of Prosthodontics and Periodontology, University of Sao Paulo Bauru School of Dentistry, Bauru, SP, Brazil, 17.012-901.

We describe the retrieval of a dental implant device that had been successfully osseointegrated for more than 4 years. After obtaining an informed patient consent, the device was retrieved for retreatment purposes from its position in a β-tricalcium phosphate (β-TCP) grafted sinus floor. The sinus floor augmentation, using β-TCP, had been performed in conjunction with the original implant placement, which in turn enabled the histological evaluation of specific regions of interest that were comprised of either grafted or native bone.

View Article and Find Full Text PDF

Background: Little is studied about complications related to probiotic ingestion. This study proposes to present a synthesis and critical evaluation of the reports and series of cases on the infectious complications related to the ingestion of probiotics, which can raise awareness for the prescribing and use of probiotics for certain groups of patients.

Methods: Systematic review of reports and series of cases researched in the PubMed, SciELO and Scopus databases published until August 2018.

View Article and Find Full Text PDF

Erysipelatoid Carcinoma (EC), also known as Inflammatory Metastatic Carcinoma, is a rare form of cutaneous metastasis, secondary to an internal malignancy, more often related to breast cancer. Clinically, the lesion has a well-marked, bound erythematous appearance, much like an infectious process, such as erysipelas and cellulitis, these being the most common differential diagnoses. It is characterized by an acute or subacute appearance with an erythematous plaque, sometimes hot and painful, being more often situated in the primary tumor vicinity, especially in the thorax wall in the region of a mastectomy due to breast cancer.

View Article and Find Full Text PDF

This article represents data associated with a prior publication from our research group, under the title: Evaluation of microvascular endothelial function and capillary density in patients with infective endocarditis using laser speckle contrast imaging and video-capillaroscopy [1]. Patients with definite infective endocarditis, under stable clinical conditions, were prospectively included. The clinical and laboratory features are presented for each of them in raw form.

View Article and Find Full Text PDF

Purpose: To evaluate the fracture resistance after the thermal and mechanical fatigue of feldspathic, lithium disilicate, and resin-modified CAD/CAM monolithic crowns cemented onto a universal post abutment.

Materials And Methods: A right second mandibular molar was designed in CAD/CAM software, and 30 crowns were machined using three different materials (n = 10): feldspathic ceramic, finished only with a glaze cycle (G1); lithium disilicate, sintered and finished with a glaze cycle (G2); and resin, modified by nanoceramic and finished with rubber (G3). All crowns were cemented under a constant 50 N load, the excess cement was removed, and the crowns were light-cured for 30 seconds.

View Article and Find Full Text PDF

Aim: To evaluate the effects of the [NaF 12 g L  + NaCl 1 g L ] solution used in the electrochemical dissolution process of fractured endodontic files, as well as its NiTi-containing product, on dentine hardness, topography and human fibroblast viability.

Methodology: Sixty single-rooted human teeth were evaluated for dentine microhardness using the Vickers hardness test and the area and number of dentinal tubules by scanning electron microscopy. The samples were divided according to the dentine surface treatment: distilled water; 17% EDTA; [NaF 12 g L  + NaCl 1 g L ]; and 17% EDTA + [NaF 12 g L  + NaCl 1 g L ].

View Article and Find Full Text PDF

Objective: Infective endocarditis is a severe condition with high in-hospital and 5-year mortality. There is increasing incidence of infective endocarditis, which may be related to healthcare and changes in prophylaxis recommendations regarding oral procedures. Few studies have evaluated the microcirculation in patients with infective endocarditis, and so far, none have utilized laser-based technology or evaluated functional capillary density.

View Article and Find Full Text PDF

Invasive multiple cervical root resorptions after vital tooth bleaching is a rare condition. The aim of this article is to present a case of multiple external cervical root resorptions (ECRR) after a misguided home whitening treatment. A 34 year old male patient presented with slight sensitivity and mobility in several teeth.

View Article and Find Full Text PDF

Microleakage at Different Implant-Abutment Connections Under Unloaded and Loaded Conditions.

Implant Dent

June 2017

*Professor, Department of Prosthodontics, School of Dentistry, Federal University of Rio Grande do Norte, Natal, Rio Grande do Norte, Brazil. †PhD Student, Department of Occlusion, Fixed Prostheses, and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil. ‡PhD Student, Department of Prosthodontics, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. §Professor, Department of Prosthodontics, Health Sciences Center, Unigranrio University, Duque de Caxias, Rio de Janeiro, Brazil. ¶Titular Professor, Department of Prosthodontics, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. ‖Associate Professor, Department of Occlusion, Fixed Prostheses, and Dental Materials, Dentistry School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.

Purpose: This study evaluated the microleakage at different implant-abutment (I-A) connections under unloaded and loaded conditions.

Materials And Methods: Forty implants, specially designed with an opening at the apex, were grouped according to the I-A and screw device: external hexagon implants with titanium (EH) or EH diamond-like carbon screws fixing the abutment; internal hexagon implants with titanium screws (IH); and Morse taper implants with solid (MT) or MT passing screws (MTps) abutments. The implants were fixed in a 2-compartment device, and toluidine blue solution (1.

View Article and Find Full Text PDF