21 results match your criteria: "U.O. Senologia Clinica e Screening Mammografico[Affiliation]"

Contrast-enhanced mammography (CEM) is rapidly expanding as a credible alternative to MRI in various clinical settings. The purpose of this study was to compare CEM and MRI for neoadjuvant therapy (NAT) response assessment in patients with breast cancer. This prospective study included 51 patients (mean age, 46 ± 11 [SD] years) with biopsy-proven breast cancer who were candidates for NAT from May 2015 to April 2018.

View Article and Find Full Text PDF
Article Synopsis
  • - The Trento screening program shifted to digital breast tomosynthesis (DBT) due to its proven effectiveness in detecting breast cancer more accurately than traditional mammography, leading to a pilot study evaluating this transition.
  • - In the study, 46,343 women underwent DBT screening and detected 402 breast cancers, resulting in a cancer detection rate (CDR) of 8.67 per 1000 screens, compared to 205 cancers with a CDR of 5.48 per 1000 screens from a historical digital mammography (DM) group.
  • - DBT screening demonstrated lower recall rates (2.55% vs. 3.21%), higher sensitivity (88.74% vs. 80.
View Article and Find Full Text PDF

Purpose: Tomosynthesis is proposed to improve breast cancer assessment and staging. We compared tomosynthesis and mammography in estimating the size of newly-diagnosed breast cancers.

Methods: All pathologically-confirmed cancers detected in the STORM-2 trial (90 cancers, 85 women) were retrospectively measured on tomosynthesis by two independent readers.

View Article and Find Full Text PDF

Background: We previously reported the Screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that tomosynthesis (3D-mammography) screening detected more cancers than 2D-mammography in double-reading practice. In this study, we report reader-specific detection measures for radiologists who performed the screen-reading in this trial.

Methods: This is a sub-study of the STORM-2 trial which prospectively integrated 3D-mammography with acquired or synthetized 2D-mammograms in parallel double-reading arms.

View Article and Find Full Text PDF

Background & Methods: The prospective 'screening with tomosynthesis or standard mammography' (STORM) trial recruited women participating in biennial breast screening in Italy (2011-2012), and compared sequential screen-readings based on 2D-mammography alone or based on tomosynthesis (integrated 2D/3D-mammography). The STORM trial showed that tomosynthesis screen-reading significantly increased breast cancer detection compared to 2D-mammography alone. The present study completes reporting of the trial by examining interval breast cancers ascertained at two year follow-up.

View Article and Find Full Text PDF

Purpose: A strong association between breast arterial calcifications (BAC) and cardiovascular disease has been demonstrated. However, BAC quantification tools are lacking. We evaluated the intra- and inter-observer reproducibility of a semi-automatic tool for BAC quantification on digital mammograms.

View Article and Find Full Text PDF

Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis.

Eur Radiol

February 2018

Screening and Test Evaluation Program (STEP), School of Public Health, Sydney Medical School, University of Sydney, Sydney, Australia.

Objectives: To compare radiation dose delivered by digital mammography (FFDM) and breast tomosynthesis (DBT) for a single view.

Methods: 4,780 FFDM and 4,798 DBT images from 1,208 women enrolled in a screening trial were used to ground dose comparison. Raw images were processed by an automatic software to determine volumetric breast density (VBD) and were used together with exposure data to compute the mean glandular dose (MGD) according to Dance's model.

View Article and Find Full Text PDF

This position paper, issued by ICBR/SIRM and GISMa, summarizes the evidence on DBT and provides recommendations for its use. In the screening setting, DBT in adjunct to digital mammography (DM) increased detection rate by 0.5-2.

View Article and Find Full Text PDF

Background: Most population breast cancer (BC) screening programs use double-reading of 2D-mammography. We recently reported the screening with tomosynthesis or standard mammography-2 (STORM-2) trial, showing that double-read tomosynthesis (pseudo-3D-mammography) detected more BC than double-read 2D-mammography. In this study, we compare screen-detection measures for single-reading of 3D-mammography with those for double-reading of 2D-mammography, to inform screening practice.

View Article and Find Full Text PDF

Breast cancers detected in only one of two arms of a tomosynthesis (3D-mammography) population screening trial (STORM-2).

Breast

April 2017

Sydney School of Public Health, Sydney Medical School, University of Sydney, Sydney, Australia. Electronic address:

The prospective 'screening with tomosynthesis or standard mammography-2 (STORM-2)' trial compared mammography screen-reading strategies and showed that each of integrated 2D/3D-mammography or 2Dsynthetic/3D-mammography detected significantly more breast cancers than 2D-mammography alone. This short report describes 13 (from 90) cancers detected in only one of two parallel double-reading arms implemented in STORM-2. Amongst this subset of cases, the majority was invasive cancer ≤16 mm, mostly depicted as irregular masses or distortions.

View Article and Find Full Text PDF

Women who were previously treated for breast cancer (BC) are an important particular subgroup of women at intermediate BC risk. Their breast follow-up should be planned taking in consideration a 1.0-1.

View Article and Find Full Text PDF

Women who underwent chest radiation therapy (CRT) during pediatric/young-adult age (typically, lymphoma survivors) have an increased breast cancer risk, in particular for high doses. The cumulative incidence from 40 to 45 years of age is 13-20 %, similar to that of BRCA mutation carriers for whom contrast-enhanced magnetic resonance imaging (MRI) is recommended. However, in women who underwent CRT, MRI sensitivity is lower (63-80 %) and that of mammography higher (67-70 %) than those observed in women with hereditary predisposition, due to a higher incidence of ductal carcinoma in situ with microcalcifications and low neoangiogenesis.

View Article and Find Full Text PDF

Background: Breast tomosynthesis (pseudo-3D mammography) improves breast cancer detection when added to 2D mammography. In this study, we examined whether integrating 3D mammography with either standard 2D mammography acquisitions or with synthetic 2D images (reconstructed from 3D mammography) would detect more cases of breast cancer than 2D mammography alone, to potentially reduce the radiation burden from the combination of 2D plus 3D acquisitions.

Methods: The Screening with Tomosynthesis Or standard Mammography-2 (STORM-2) study was a prospective population-based screening study comparing integrated 3D mammography (dual-acquisition 2D-3D mammography or 2D synthetic-3D mammography) with 2D mammography alone.

View Article and Find Full Text PDF

Digital breast tomosynthesis as an adjunct to digital mammography for detecting and characterising invasive lobular cancers: a multi-reader study.

Clin Radiol

September 2016

Department of Diagnostic Imaging and Radiotherapy, Radiology Institute, University of Turin, A. O. U. Cittá della Salute e della Scienza di Torino - Presidio Ospedaliero Molinette, Via Genova 3, 10126 Torino, Italy.

Aim: To examine the interpretive performance of digital breast tomosynthesis (DBT) as an adjunct to digital mammography (DM) compared to DM alone in a series of invasive lobular carcinomas (ILCs) and to assess whether DBT can be used to characterise ILC.

Materials And Methods: A retrospective, multi-reader study was conducted of 83 mammographic examinations of women with 107 newly diagnosed ILCs ascertained at histology. Consenting women underwent both DM and DBT acquisitions.

View Article and Find Full Text PDF

This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening.

View Article and Find Full Text PDF

Purpose: We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial.

Methods: STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up.

View Article and Find Full Text PDF

Objective: We investigated the effect of integrating three-dimensional (3D)-mammography with 2D-mammography on radiologists' detection measures in the 'screening with tomosynthesis or standard mammography' (STORM) trial.

Methods: STORM, a prospective population-based trial (Trento and Verona breast screening services) compared sequential screen-reading: 2D-mammography alone and integrated 2D/3D-mammography. Radiologist-specific detection measures were calculated for each screen-reading phase for eight radiologists: number of detected cancers, proportion of true-positive (TP) detection, and number and rate of false-positive (FP) recalls (FPR).

View Article and Find Full Text PDF

Background & Objectives: Three-dimensional (3D)-mammography (tomosynthesis) may improve breast cancer detection. We examined centre-specific effect of integrated 2D/3D mammography based on the STORM (screening with tomosynthesis or standard mammography) trial.

Methods: Asymptomatic women who attended population-based screening through Trento and Verona screening centres were recruited into STORM, a prospective comparison of screen-reading in two sequential phases: 2D-mammography only and integrated 2D/3D mammography.

View Article and Find Full Text PDF

Objective: The aim of this study was to supplement the paucity of information available on logistical aspects of the application of three-dimensional (3D) mammography in breast screening.

Methods: We prospectively examined the effect on radiographers' and radiologists' workload of implementing 3D mammography in screening by comparing image acquisition time and screen-reading time for two-dimensional (2D) mammography with that of combined 2D+3D mammography. Radiologists' accuracy was also calculated.

View Article and Find Full Text PDF

EUSOMA criteria for performing pre-operative MRI staging in candidates for breast conserving surgery: hype or helpful?

Breast

June 2012

U.O. Senologia Clinica e Screening Mammografico, Dipartimento di Radiodiagnostica, APSS, Trento I, Viale Verona Centro per i Servizi Sanitari, Palazzina C, Piano Terrazza 38100, Trento, Italy.

Ongoing debate regarding the value of pre-operative MRI in staging patients with newly diagnosed breast cancer has resulted from the lack of evidence on its clinical efficacy, which contrasts MRIs capability for detecting additional disease (occult on conventional imaging) in the cancerous breast. We undertook a validation study of EUSOMA criteria that recommend selection of breast conserving surgery (BCS) candidates to pre-operative MRI. We examined whether these criteria were associated with a differential likelihood of a recommendation for mastectomy.

View Article and Find Full Text PDF

Interobserver agreement in breast radiological density attribution according to BI-RADS quantitative classification.

Radiol Med

June 2012

U.O. Senologia Clinica e Screening Mammografico, Dipartimento di Radiodiagnostica, APSS Trento I, Viale Verona Centro per i Servizi Sanitari, Palazzina C, Piano Terrazza, 38100, Trento, Italy.

Purpose: The authors sought to assess interobserver agreement in classifying mammography density according to quantitative Breast Imaging Reporting and Data System (BI-RADS) criteria.

Materials And Methods: Six expert mammography readers were tested on a set of 100 mammograms. Interobserver agreement was determined according to the kappa statistic, adjusting for chance agreement, on a four-category (D1 vs.

View Article and Find Full Text PDF