4 results match your criteria: "St. Kliment Ohridsky University of Sofia[Affiliation]"
Appl Radiat Isot
January 2020
"Jožef Stefan" Institute, Jamova Cesta 39, 1000, Ljubljana, Slovenia.
The probabilities of locating peaks with a high relative peak-area uncertainty were determined empirically with nine types of peak-location software used in laboratories engaged in gamma-ray spectrometry measurements. It was found that it is not possible to locate peaks with a probability of 0.95, when they have a relative peak-area uncertainty in excess of 50%.
View Article and Find Full Text PDFAdv Protein Chem Struct Biol
April 2011
St. Kliment Ohridsky University of Sofia, Bulgaria.
The use of proteins as a substrate in the fabrication of micro- and nanoparticulate systems has attracted the interest of scientists, manufactures, and consumers. Albumin-derived particles were commercialized as contrast agents or anticancer therapeutics. Food proteins are widely used in formulated dietary products.
View Article and Find Full Text PDFMet Based Drugs
July 2011
Department of Analytical Chemistry, Faculty of Chemistry, St. Kliment Ohridsky University of Sofia, 1 J. Bourchier Boulevard, 1164 Sofia, Bulgaria.
Three novel stable Pt(III) complexes with distorted octahedral structure and (dz2)1 ground state have been obtained in the course of Pt(II)-hematoporphyrin IX ((7,12-bis(1-hydroxyethyl)-3,8,13,17-tetramethyl-21H-23H-porphyn-2,18-dipropionic acid), Hp) interaction in alkaline aqueous medium and aerobic conditions. A redox interaction also takes place together with the complexation process leading to the formation of Pt(III) species and organic radicals. The processes in the reaction system and the structure of the complexes formed cis-[Pt(III)(NH3)2(Hp-3H)(H2O)2]H2O1, [Pt(III)(Hp-3H)(H2O)2]H2O2, and [Pt((O,O)Hp-2H)Cl(H2O)3] 3, were studied by UV-Vis, IR, EPR and XPS spectra, thermal (TGS, DSC), potentiometric and magnetic methods.
View Article and Find Full Text PDFAppl Radiat Isot
May 2001
Faculty of Physics, St. Kliment Ohridsky University of Sofia, Bulgaria.
On the basis of the measurement of over 70 radioactive standard bulk sources with different matrix density and different shapes, the gamma-ray self-attenuation corrections needed in activity determination by means of gamma-ray spectrometry are evaluated. The full-energy peak efficiency dependence on the density, and the self-attenuation correction dependence on the photon energy are described.
View Article and Find Full Text PDF