166 results match your criteria: "ShenZhen Institute of Transfusion Medicine[Affiliation]"
HLA
October 2017
Immunogenetic Laboratory, Shenzhen Blood Center, Shenzhen Institute of Transfusion Medicine, Shenzhen, China.
The full‐length sequence of HLA‐B*59:01:01:01.
View Article and Find Full Text PDFHLA
August 2017
Shenzhen Blood Center, Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen, Guangdong Province, China.
Full-length sequences of HLA-B*48:03:01 and B*48:04:01, confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
August 2017
Shenzhen Blood Center, Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen, China.
Confirmed the full-length sequence of HLA-B*44:03:02 by cloning and sequencing in a Chinese donor.
View Article and Find Full Text PDFHLA
July 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
Full-length sequence of HLA-B*55:02:01:01, confirmed by cloning and sequencing in a Chinese donor.
View Article and Find Full Text PDFHLA
July 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
Full-length sequences of HLA -B*27:04:01, B*27:07:01 and B*27:25, confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
May 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequences of HLA-B*40:01:01, B*40:03 and B*40:40, confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
May 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
We report the full-length sequence of 4 HLA-B*15 alleles, B*15:07:01:01, B*15:27:01, B*15:32:01 and B*15:58.
View Article and Find Full Text PDFHLA
May 2017
Shenzhen Blood Center, Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen, China.
Full-length sequences of HLA-B*67:01:01 and B*67:01:02, confirmed by cloning and sequencing from Chinese donors.
View Article and Find Full Text PDFHLA
May 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequences of 4 alleles of HLA-B*35 gene family, confirmed by cloning and sequencing.
View Article and Find Full Text PDFHLA
May 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
We report the full-length sequences of 4 alleles of the HLA-B*15 gene family.
View Article and Find Full Text PDFHLA
May 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequences of HLA-B*07:05:01:01, B*14:01:01 and B*18:02, confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
April 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequences of HLA-B*56:01:01:01, B*56:03 and B*56:04, confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
March 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequences of HLA-B*39:05:01 and B*39:38Q , confirmed by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
March 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
Full-length sequence of HLA-B*52:01:01:01 and B*52:01:02:01, identified by cloning and sequencing in Chinese donors.
View Article and Find Full Text PDFHLA
January 2017
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
HLA-DQB1*03:01:34 has one nucleotide change from HLA- DQB1*03:01:01 at nucleotide 357 bp where C>A in exon 2.
View Article and Find Full Text PDFHLA
December 2016
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
HLA-B*15:374 has one nucleotide change from HLA-B*15:02:01 at nucleotide 553 bp where G → A in exon 3.
View Article and Find Full Text PDFHLA
September 2016
Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
HLA-A*24:325 differs from A*24:02:01:01 by two nucleotide substitutions at position 411 and 412.
View Article and Find Full Text PDFHLA
January 2016
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
A*02:432 differs from A*02:07:01 by one nucleotide change at nucleotide 572 in exon 3 from G to C.
View Article and Find Full Text PDFTissue Antigens
October 2015
Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
HLA-A*24:02:09 shows one nucleotide difference from HLA-A*24:02:01:01 at position 408 in exon 3 (codon 112 GGG>GGC).
View Article and Find Full Text PDFTissue Antigens
October 2015
Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
A novel HLA-DQB1 allele, DQB1*05:10, was detected in a Chinese individual by cloning and sequencing.
View Article and Find Full Text PDFTissue Antigens
February 2015
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
A*33:03:13 differs from A*33:03:01 by one nucleotide change at nucleotide 714 in exon 4 from A to G.
View Article and Find Full Text PDFTissue Antigens
October 2014
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
The novel HLA-B*51:144 allele shows one nucleotide difference from B*51:02:02 in exon 3.
View Article and Find Full Text PDFTissue Antigens
September 2014
Immunogenetic Laboratory, Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, China.
A*02:01:79 is identical to A*02:01:01:01, except for one nucleotide change at nt 762 in exon 4 from C to T.
View Article and Find Full Text PDFTissue Antigens
August 2014
Shenzhen Blood Center, Shenzhen Institute of Transfusion Medicine, Shenzhen, Guangdong, China.
Tissue Antigens
April 2014
Shenzhen Institute of Transfusion Medicine, Shenzhen Blood Center, Shenzhen, Guangdong, China.
We describe here a novel null allele of human leukocyte antigen gene, A*11:69N, which was initially found in a blood donor from China.
View Article and Find Full Text PDF