Objectives: According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest.

Methods: We developed the "APS Calculator" allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU.

View Article and Find Full Text PDF

Alanine aminotransferase (ALT) represents the first-level test to detect individuals with hepatocellular damage of any etiology. However, it has been highlighted that the lack of assay harmonization may lead to overdiagnosis and unnecessary further testing if guideline-recommended fixed cut-offs are uncritically employed. To solve the issue of ALT (dis)harmonization and improve the interpretation of its values, a series of urgent actions for documenting and validating metrological traceability of serum ALT measurements, as described in this paper, are no longer postponeable.

View Article and Find Full Text PDF

Objectives: Recently, Abbott Diagnostics marketed a new generation of Alinity enzyme assays, introducing a multiparametric calibrator [Consolidated Chemistry Calibrator (ConCC)] in place of or in addition to factor-based calibrations. For alkaline phosphatase (ALP), both calibration options are offered, i.e.

View Article and Find Full Text PDF

In reply to: Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability.

Clin Chem Lab Med

October 2023

Department of Biomedical and Clinical Sciences "Luigi Sacco", Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy.

View Article and Find Full Text PDF

The Joint Committee for Traceability in Laboratory Medicine (JCTLM) currently lists the secondary commutable certified reference material (CRM) ERM DA-474/IFCC (DA-474) "C-Reactive Protein in Human Serum" and two generic immunoassay-based method principles as the basis for implementing the metrological traceability of C-reactive protein (CRP) measurements by end-user measurement procedures used by medical laboratories. The current metrological traceability has produced well harmonized results for clinical samples among different end-user measurement procedures. New higher-order pure substance and secondary commutable CRMs have been nominated for listing by the JCTLM.

View Article and Find Full Text PDF

From External Quality Assessment data, current harmonization of CRP measuring systems appears to be satisfactory, the inter-assay CV being well below 10%. The inter-method variability is even better (close to 3%) when the widely used measuring systems are compared at CRP concentrations employed as cut-off for detecting sub-clinical infection (i.e.

View Article and Find Full Text PDF

Elevated liver enzyme activity may be associated with metabolic syndrome (MetS); however, it is not included in the MetS definition for children. Postprandial changes in the levels of biochemistry tests are related to manifestations of metabolic abnormalities. We assessed the association between fasting and postprandial liver enzymes levels with MetS and elevated hemoglobin A1c (HbA1c) in children aged 9-11.

View Article and Find Full Text PDF

Equivalent results for the same measurand in clinical samples (CSs), measured using different end-user in-vitro diagnostic medical devices (IVD-MDs), are essential for the application of clinical practice guidelines for diagnosis, treatment, monitoring, or risk assessment. The International Organization for Standardization (ISO) document 17511:2020 specifies how to establish metrological traceability to the highest available reference system component to enable equivalent results among IVD-MDs. Commutability with CSs is an essential property of a reference material used as a calibrator in a calibration hierarchy.

View Article and Find Full Text PDF

Laboratories should estimate and validate [using analytical performance specifications (APS)] the measurement uncertainty (MU) of performed tests. It is therefore essential to appropriately define APS for MU, but also to provide a perspective on suitability of the practical application of these APS. In this study, 23 commonly ordered measurands were allocated to the models defined during the 2014 EFLM Strategic Conference to derive APS for MU.

View Article and Find Full Text PDF

Alignment of the new generation of Abbott Alinity γ-glutamyltransferase assay to the IFCC reference measurement system should be improved.

Clin Chem Lab Med

September 2022

Clinical Pathology Unit, ASST Fatebenefratelli-Sacco, Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy.

View Article and Find Full Text PDF

Background: Serum ferritin is considered a suitable biomarker of iron-related disorders. However, data about the comparability of results among commercial measuring systems (MSs) are contradictory. We performed an intercomparison study aimed at verifying the current interassay variability and its impact on clinical application of the test.

View Article and Find Full Text PDF

Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Laboratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use.

View Article and Find Full Text PDF

Objectives: Biological variation data (BV) can be used for different applications, but this depends on the availability of robust and relevant BV data. In this study, we aimed to summarize and appraise BV studies for tumor markers, to examine the influence of study population characteristics and concentrations on BV estimates and to discuss the applicability of BV data for tumor markers in clinical practice.

Methods: Studies reporting BV data for tumor markers related to gastrointestinal, prostate, breast, ovarian, haematological, lung, and dermatological cancers were identified by a systematic literature search.

View Article and Find Full Text PDF

γ-Glutamyltransferase reference intervals in detail.

Liver Int

March 2022

Department of Biomedical and Clinical Sciences and Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), Università degli Studi di Milano, Milan, Italy.

View Article and Find Full Text PDF

Objectives: The TOP-HOLE (Towards OPtimal glycoHemOgLobin tEsting) project aimed to validate the HbA enzymatic method on the Abbott Alinity c platform and to implement the HbA testing process on the total laboratory automation (TLA) system of our institution.

Methods: Three different measuring systems were employed: Architect c4000 stand-alone (s-a), Alinity c s-a, and Alinity c TLA. Eight frozen whole blood samples, IFCC value-assigned, were used for checking trueness.

View Article and Find Full Text PDF

Biological variation estimates of thyroid related measurands - meta-analysis of BIVAC compliant studies.

Clin Chem Lab Med

March 2022

Analytical Quality Commission, Spanish Society of Laboratory Medicine (SEQCML), Barcelona, Spain.

Objectives: Testing for thyroid disease constitutes a high proportion of the workloads of clinical laboratories worldwide. The setting of analytical performance specifications (APS) for testing methods and aiding clinical interpretation of test results requires biological variation (BV) data. A critical review of published BV studies of thyroid disease related measurands has therefore been undertaken and meta-analysis applied to deliver robust BV estimates.

View Article and Find Full Text PDF