36 results match your criteria: "Rainier Clinical Research Center[Affiliation]"
Diabetes Technol Ther
April 2024
Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC) that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing.
View Article and Find Full Text PDFNat Med
November 2023
Center for Human Nutrition, Washington University School of Medicine, St. Louis, MO and Sansum Diabetes Research Institute, Santa Barbara, CA, USA.
Diabetes Ther
April 2023
Abbott Diabetes Care, Alameda, CA, USA.
Introduction: We have evaluated the performance of the FreeStyle Libre® 3 continuous glucose monitoring system (FSL3) compared to (1) the venous plasma reference for participants aged ≥ 6 years and (2) the fingerstick capillary blood glucose (BG) reference for pediatric participants aged 4 and 5 years. The analytical performance of the third-generation factory-calibrated FSL3 CGM system was compared to the plasma venous blood glucose reference using the YSI 2300 STAT PLUS Glucose and Lactate Analyzer (the YSI reference) and the self-monitoring blood glucose (SMBG) reference for participants aged ≥ 6 years and participants aged 4 and 5 years, respectively.
Methods: A total of 108 participants aged ≥ 4 years with type 1 or type 2 diabetes from four sites in the USA were enrolled in the study.
Diabetes Technol Ther
January 2023
Medtronic, Northridge, California, USA.
To evaluate safety and effectiveness of MiniMed™ 670G hybrid closed loop (HCL) in comparison with continuous subcutaneous insulin infusion (CSII) therapy for 6 months in persons with type 1 diabetes (T1D). Adults (aged 18-80 years), adolescents, and children (aged 2-17 years) with T1D who were using CSII therapy were enrolled and randomized (1:1) to 6 months of HCL intervention (n = 151, mean age of 39.9 ± 19.
View Article and Find Full Text PDFNat Med
October 2022
Center for Human Nutrition, Washington University School of Medicine, St. Louis, MO and Sansum Diabetes Research Institute, Santa Barbara, CA, USA.
Hyperglucagonemia contributes to hyperglycemia in patients with type 1 diabetes (T1D); however, novel therapeutics that block glucagon action could improve glycemic control. This phase 2 study evaluated the safety and efficacy of volagidemab, an antagonistic monoclonal glucagon receptor (GCGR) antibody, as an adjunct to insulin therapy in adults with T1D. The primary endpoint was change in daily insulin use at week 12.
View Article and Find Full Text PDFDiabetes Technol Ther
August 2022
Stanford University School of Medicine, Palo Alto, California, USA.
Standard insulin infusion sets (IISs) are to be replaced every 2 to 3 days to avoid complications and diabetic ketosis due to set failure. This pivotal trial evaluated the safety and performance of a new extended-wear infusion set (EIS) when used for 7 days by adults with type 1 diabetes (T1D). This single-arm, nonrandomized trial enrolled adults (18-80 years of age) with T1D, who used their own MiniMed™ 670G system with insulin lispro or insulin aspart and the EIS for up to 7 days, across 12 consecutive wears.
View Article and Find Full Text PDFDiabetes Technol Ther
March 2022
Medtronic, Northridge, California, USA.
This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14-21 years and 118 adults aged ≥22-75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/- predictive low glucose management or Auto Basal was enabled for ∼14 days.
View Article and Find Full Text PDFDiabetes Technol Ther
February 2022
Senseonics, Inc., Germantown, Maryland, USA.
Use of continuous glucose monitoring (CGM) systems is being rapidly adopted as standard of care for insulin-requiring patients with diabetes. The PROMISE study (NCT03808376) evaluated the accuracy and safety of the next-generation implantable Eversense CGM system for up to 180 days. This was a prospective multicenter study involving 181 subjects with diabetes at 8 USA sites.
View Article and Find Full Text PDFDiabetes Obes Metab
October 2021
Zealand Pharma A/S, Søborg, Denmark.
Aim: To confirm the efficacy and safety of dasiglucagon when administered via an autoinjector device.
Materials And Methods: In this double-blind trial, 45 participants with type 1 diabetes were randomized 3:1 to receive a single subcutaneous dose of dasiglucagon 0.6 mg or placebo following controlled induction of hypoglycaemia.
J Diabetes Sci Technol
September 2022
Calibra Medical, Johnson & Johnson Diabetes Care Companies, Wayne, PA, USA.
Objective: CeQur Simplicity™ (CeQur, Marlborough, MA) is a 3-day insulin delivery patch designed to meet mealtime insulin requirements. A recently reported 48-week, randomized, multicenter, interventional trial compared efficacy, safety and self-reported outcomes in 278 adults with type 2 diabetes (T2D) on basal insulin therapy who initiated and managed mealtime insulin therapy with a patch pump versus insulin pen. We assessed changes in key glycemic metrics among a subset of patients who wore a continuous glucose monitoring (CGM) device.
View Article and Find Full Text PDFDiabetes Ther
February 2021
Gemeinschaftspraxis fur Innere Medizin und Diabetologie, Hamburg, Germany.
Introduction: The PRONTO-T1D study, which evaluated the efficacy and safety of ultra rapid lispro (URLi) versus lispro in adults with type 1 diabetes (T1D), met the primary endpoint of noninferiority of HbA1c change from baseline compared to lispro at 26 weeks. We present results of an additional 26-week treatment phase evaluating long-term efficacy and safety of URLi.
Methods: In this phase 3, treat-to-target study, subjects were randomized to double-blind mealtime URLi, lispro, or open-label postmeal URLi with insulin degludec or glargine for 26 weeks.
J Diabetes Sci Technol
November 2021
Ascensia Diabetes Care Holdings AG, Basel, Switzerland.
Introduction: Self-monitoring of blood glucose (BG) is important in diabetes management, allowing people with diabetes (PWD) to assess responses to diabetes therapy and to inform if they are attaining their glycemic targets. This study assessed the accuracy and user performance (UP) of a new blood glucose monitoring system (BGMS), CONTOUR®PLUS ELITE, according to International Organization for Standardization (ISO) 15197:2013 criteria and also more stringent criteria.
Methods: In laboratory Study 1, capillary fingertip blood samples from 100 PWD were evaluated using the new BGMS.
J Diabetes Sci Technol
January 2022
Abbott Diabetes Care, Alameda, CA, USA.
Background: In this study, we evaluated the analytical performance of the second-generation factory-calibrated FreeStyle Libre Flash Glucose Monitoring (FreeStyle Libre 2) System compared to plasma venous blood glucose reference, Yellow Springs Instrument 2300 (YSI).
Methods: The study enrolled participants aged four and above with type 1 or type 2 diabetes at seven sites in the United States. Adult participants (18+ years) participated in three in-clinic sessions and pediatric participants (4-17 years) participated in up to two in-clinic sessions stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13, or 14 of sensor wear.
Diabetes Technol Ther
May 2019
3 Calibra Medical, Johnson & Johnson Diabetes Care Companies, Wayne, Pennsylvania.
Barriers to mealtime insulin include complexity, fear of injections, and lifestyle interference. This multicenter, randomized controlled trial evaluated efficacy, safety, and self-reported outcomes in adults with type 2 diabetes, inadequately controlled on basal insulin, initiating and managing mealtime insulin with a wearable patch versus an insulin pen. Adults with type 2 diabetes ( = 278, age: 59.
View Article and Find Full Text PDFDiabetes Technol Ther
May 2019
5 Senseonics, Inc., Germantown, Maryland.
A prior study (PRECISE II) demonstrated that an implantable continuous glucose monitoring (CGM) system (Eversense CGM System) provided accurate glucose readings through the 90-day sensor life with a favorable safety profile in participants with type 1 or type 2 diabetes (T1D, T2D). This study was performed to further characterize the accuracy of the system. PRECISION was a prospective multicenter study that evaluated the accuracy and safety of Eversense among adults with T1D or T2D through 90 days (NCT02647905).
View Article and Find Full Text PDFJ Diabetes Sci Technol
September 2020
Abbott Rapid Diagnostics, a division of Abbott Laboratories, San Diego, CA, USA.
Diabetes Technol Ther
October 2018
1 Barbara Davis Center for Diabetes, University of Colorado Denver, Aurora, Colorado.
Background: The majority of therapies have generally targeted fasting glucose control, and current mealtime insulin therapies have longer time action profiles than that of endogenously secreted insulin. The primary purpose of this study was to assess both glucose time-in-range (TIR: 70-180 mg/dL) and postprandial glucose excursions (PPGE) in 1-4 h using a real-time continuous glucose monitor (CGM) with Technosphere insulin (TI) versus insulin aspart in patients with type 1 diabetes (T1DM) on multiple daily injections (MDI).
Research Design And Methods: This pilot, investigator-led, collaborative, open-label, multicenter, clinical research trial enrolled 60 patients with T1DM with HbA1c levels ≥6.
Diabetes Technol Ther
September 2018
12 Medtronic , Northridge, California.
Background: This study evaluated the safety and performance of the Guardian™ continuous glucose monitoring (CGM) system in children and adolescents with type 1 diabetes (T1D).
Materials And Methods: Subjects 2-18 years of age (mean ± standard deviation [SD] 13.1 ± 3.
Diabetes Care
August 2018
Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, CA.
Objective: Cleared blood glucose monitors (BGMs) for personal use may not always deliver levels of accuracy currently specified by international and U.S. regulatory bodies.
View Article and Find Full Text PDFDiabetes Technol Ther
March 2018
9 AMCR Institute, Inc. , Escondido, California.
Background: Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D).
Methods: PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable Eversense CGM system among adult participants with T1D and T2D (NCT02647905). The primary endpoint was the mean absolute relative difference (MARD) between paired Eversense and Yellow Springs Instrument (YSI) reference measurements through 90 days postinsertion for reference glucose values from 40 to 400 mg/dL.
Diabetes Technol Ther
December 2017
1 Medtronic , Northridge, California.
A 3-month pivotal trial using the MiniMed™ 670G hybrid closed-loop (HCL) system in adolescent and adult patients with type 1 diabetes (T1D), relative to a 2-week baseline run-in period, resulted in increased sensor glucose (SG) values in target range (71-180 mg/dL), reduced HbA1c levels, and no events of diabetic ketoacidosis or severe hypoglycemia ( Clinicaltrials.gov : NCT02463097). This brief report evaluated how prior continuous glucose monitoring (CGM) experience influenced glycemic outcomes, in the same pivotal trial.
View Article and Find Full Text PDFDiabetes Technol Ther
August 2017
6 Medtronic , Northridge, California.
Background: This study evaluated the accuracy and performance of a fourth-generation subcutaneous glucose sensor (Guardian Sensor 3) in the abdomen and arm.
Methods: Eighty-eight subjects (14-75 years of age, mean ± standard deviation [SD] of 42.0 ± 19.
Diabetes Technol Ther
May 2017
9 Medtronic, Northridge, California.
Background: Predictions based on continuous glucose monitoring (CGM) data are the basis for automatic suspension and resumption of insulin delivery by a predictive low-glucose management feature termed "suspend before low," which is part of the Medtronic MiniMed 640G combined insulin pump and CGM system. This study assessed the safety and performance characteristics of the system in an in-clinic setting at eight sites.
Materials And Methods: In-clinic standardized increases in basal insulin delivery rates were used to induce nocturnal hypoglycemia in subjects (14-75 years) with type 1 diabetes wearing the MiniMed 640G system.
Diabetes Technol Ther
March 2017
10 Medtronic , Northridge, California.
Background: The safety and effectiveness of the in-home use of a hybrid closed-loop (HCL) system that automatically increases, decreases, and suspends insulin delivery in response to continuous glucose monitoring were investigated.
Methods: Adolescents (n = 30, ages 14-21 years) and adults (n = 94, ages 22-75 years) with type 1 diabetes participated in a multicenter (nine sites in the United States, one site in Israel) pivotal trial. The Medtronic MiniMed 670G system was used during a 2-week run-in phase without HCL control, or Auto Mode, enabled (Manual Mode) and, thereafter, with Auto Mode enabled during a 3-month study phase.
J Diabetes Sci Technol
November 2016
Rainier Clinical Research Center, Inc, Renton, WA, USA.