1 results match your criteria: "Orthopaedic Research Institute at Good Samaritan Hospital[Affiliation]"
J Bone Joint Surg Am
July 2002
Orthopaedic Research Institute at Good Samaritan Hospital, Los Angeles, CA, USA.
Background: Press-fit implantation of a porous-coated hemispheric acetabular component without screws is an option for primary total hip replacement. The purpose of the present study was to evaluate the results of this technique after an average duration of follow-up of ten years to determine if there was any loss of fixation or increase in osteolysis over time.
Methods: From June 1988 to November 1990, 132 primary total hip replacements were performed with a porous-coated socket that was implanted with use of a press-fit technique.