10 results match your criteria: "Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery[Affiliation]"
Bone Joint Res
March 2023
The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, California, USA.
Taper corrosion has been widely reported to be problematic for modular total hip arthroplasty implants. A simple and systematic method to evaluate taper damage with sufficient resolution is needed. We introduce a semiquantitative grading system for modular femoral tapers to characterize taper corrosion damage.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
February 2023
The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA.
Study Design: Preclinical biomechanical study of topology optimization versus standard ring design for bioresorbable poly-ε-caprolactone (PCL) cervical spine fusion cages delivering bone morphogenetic protein-2 (BMP-2) using a porcine model.
Objective: The aim was to evaluate range of motion (ROM) and bone fusion, as a function of topology optimization and BMP-2 delivery method.
Summary Of Background Data: 3D printing technology enables fabrication of topology-optimized cages using bioresorbable materials, offering several advantages including customization, and lower stiffness.
Arthroplast Today
June 2022
The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA, USA.
Background: Femoral strut allografts are used in revision hip arthroplasty for management of bone loss associated with implant failure or periprosthetic fractures. They have also been used to treat unremitting thigh pain in well-fixed cementless femoral stems, to address the differential in structural stiffness between the stem and femoral shaft. Our study used an in vitro biomechanical model to measure the effect of placement of allografts on femoral strains, to determine their load-sharing capacity.
View Article and Find Full Text PDFJ Hand Surg Am
March 2022
The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA.
Purpose: This study determined the volume of bone replaced by an implant at the proximal and distal poles of simulated scaphoid fractures. We also measured the cross-sectional area of the implant relative to the cross-sectional area of the scaphoid at 2 different simulated fracture locations.
Methods: Microcomputed tomograhy scans of 7 cadaveric scaphoids were used to create 3-dimensional models in which transverse proximal pole and midwaist fractures were simulated.
Background: Increased enrollment in government-based insurance plans has been reported. With youth sports injuries on the rise, increased ordering of advanced imaging such as magnetic resonance imaging (MRI) has occurred. This study sought to report on the impact of insurance type on access to and results of knee MRI in pediatric sports medicine patients.
View Article and Find Full Text PDFClin Orthop Relat Res
November 2018
S.-H. Park, Z. Lu, P. A. Campbell, E. Ebramzadeh, The J. Vernon Luck, Sr, MD Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA, USA R. S. Hastings, DePuy, Inc, Warsaw, IN, USA.
J Orthop Res
January 2019
The J. Vernon Luck, Sr, MD Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, 403 West Adams Boulevard, Los Angeles, California, 90007.
Excessive wear has been one of the major failure modes of metal-on-metal hip implants. From a collection of 541 retrieved ASR metal-on-metal implants, we selected those head-cup pairs with combined wear >100 mm , (N = 42) to assess the distributions of wear volume on cups, and non-conformance in the worn areas at the head-cup interfaces. All 42 had severe cup edge wear (average maximum wear depth 500 μm).
View Article and Find Full Text PDFClin Orthop Relat Res
February 2018
S.-H. Park, Z. Lu, P. A. Campbell, E. Ebramzadeh, The J. Vernon Luck, Sr, MD Orthopaedic Research Center, Orthopaedic Institute for Children and UCLA Department of Orthopaedic Surgery, Los Angeles, CA, USA R. S. Hastings, DePuy, Inc, Warsaw, IN, USA.
Background: In 2010, a widely used metal-on-metal hip implant design was voluntarily recalled by the manufacturer because of higher than anticipated failure rates at 5 years. Although there was a large published range of revision rates, numerous studies had reported a higher risk of revision for excessive wear and associated adverse tissue reactions when compared with other metal-on-metal total hips. The reasons for this were suggested by some to be related to cup design features.
View Article and Find Full Text PDFActa Orthop
February 2018
b Department of Orthopedics , Radboud University Hospital, Nijmegen.
Background and purpose - Hip resurfacing (HR) is a treatment option promoted for hip arthritis in young and active patients. However, adverse reactions to metal are a concern and the search for non-metallic bearing options proceeds. We present the first clinical study performed in patients using a newly developed hydrophilic polymer-on-polymer hip resurfacing device.
View Article and Find Full Text PDFJ Bone Joint Surg Am
June 2015
Joint Replacement Institute at St. Vincent Medical Center, 2200 West Third Street, Suite 400, Los Angeles, CA 90057. E-mail address for H.C. Amstutz:
Unlabelled: Liner cementation into a preexisting stable socket may reduce the morbidity of revision hip arthroplasty and preserve acetabular bone. However, the long-term outcomes of this technique remain unknown. The purpose of this report was to analyze the long-term results of a previously reported cohort of patients.
View Article and Find Full Text PDF