9 results match your criteria: "National Environmental Research and Training Institute[Affiliation]"
Talanta
April 2022
Department of Applied Chemistry for Environment, Graduate School of Urban Environmental Sciences, Tokyo Metropolitan University, 1-1 Minamiohsawa, Hachioji, Tokyo, 192-0397, Japan. Electronic address:
A simple and low-cost method of fabricating an optical fiber for a surface plasmon resonance (SPR) sensor was proposed. The method is based on the electroless nickel plating and subsequent displacement gold plating of the core of the optical fiber. The thickness of the nickel and gold thin films deposited on the core of the optical fiber could be controlled by measuring the reflected light intensity from the tip of the optical fiber during the plating processes.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
December 2021
Faculty of Life Sciences, Toyo University, Gunma, Japan.
Telomere length is thought to be a biomarker of biological aging. This study examined whether telomere length was associated with urinary concentrations of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a biomarker of oxidative stress, and antioxidative trace elements in 73 female Japanese university students (age: 19.2 ± 0.
View Article and Find Full Text PDFJ Occup Health
January 2021
National Environmental Research and Training Institute, Ministry of the Environment Government of Japan, Tokorozawa, Saitama, Japan.
Aim: We aimed to develop a measurement method that can count fibers rapidly by scanning electron microscopy equipped with an artificial intelligence image recognition system (AI-SEM), detecting thin fibers which cannot be observed by a conventional phase contrast microscopy (PCM) method.
Methods: We created a simulation sampling filter of airborne fibers using water-filtered chrysotile (white asbestos). A total of 108 images was taken of the samples at a 5 kV accelerating voltage with 10 000X magnification scanning electron microscopy (SEM).
Anal Sci
May 2020
National Environmental Research and Training Institute, 3-3 Namiki, Tokorozawa, , Saitama 359-0042, Japan.
An automatic pH adjustment instrument was developed for the preparation of analytical samples prior to solid phase extraction, which is widely used as a pretreatment technique for the separation of sample matrixes and preconcentration of elements for analysis. Real-time monitoring of the sample pH condition was performed by observing the light signal intensity of the pH-sensitive wavelength of the pH indicating reagent. A light of pH-insensitive wavelength was selected as the reference light to cancel the signal intensity variation of the pH-sensitive light due to the difference of pH indicating reagent concentration, possible difference in transparency of sample vessels, and minute fluctuation of the light source.
View Article and Find Full Text PDFBiol Trace Elem Res
December 2019
Faculty of Life Sciences, Toyo University, 1-1-1 Izumino, Itakura, Ora, Gunma, 374-0193, Japan.
Cadmium is a toxic metal found ubiquitously throughout the world. Our study evaluated whether cadmium exposure was associated with telomere length in 73 female university students. Determination of telomere length was performed by quantitative polymerase chain reaction using DNA in blood.
View Article and Find Full Text PDFChemosphere
January 2019
Department of Molecular Life Sciences, School of Life Sciences, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo, 192-0392, Japan.
When iminodiacetic acid chelating-resin solid phase extraction (SPE) was used for the preconcentration of rare earth elements (REEs) in river water samples around sewage treatment plant (STP), low recovery values for heavy REEs were observed. In order to find out the reason for the low recovery, in the present paper, organic ligands in the STP effluent, which may compete with iminodiacetic acids, were analyzed by GC-NPD. It was found that EDTA was contained in the STP effluent at several-100 nM level and interfered with the adsorption of REEs, especially heavy REEs (present at pM level) on the chelating-resin due to the formation of stable complexes.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
March 2018
Hyogo Prefectural Institute of Environmental Sciences, Yukihira-cho 3-1-18, Suma-ku, Kobe, Hyogo, 654-0037, Japan.
Waste disposal site is one of the important sinks of chemicals. A significant amount of perfluoroalkyl and polyfluoroalkyl substances (PFASs) such as perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), and perfluorohexanoic acid (PFHxA) have been brought into it. Because of their aqueous solubility, PFASs are released to landfill effluent waters, from which PFASs are efficiently collected by adsorption technique using granular activated carbon (GAC).
View Article and Find Full Text PDFAnal Bioanal Chem
April 2004
National Environmental Research and Training Institute, Ministry of the Environment, 3-3 Namiki, Tokorozawa-shi, 359-0042, Saitama, Japan.
A solid-phase extraction (SPE) method was optimized for accurate determination of polychlorinated dibenzo- p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and coplanar polychlorinated biphenyls (CoPCBs) in humic acid containing surface water. Recovery experiments using humic materials revealed that humic acids permit dioxins to pass through an octadecylsilica (C(18)) extraction disk by associating with them under weakly alkaline conditions. Acidification of the sample before percolation improved this otherwise insufficient recovery.
View Article and Find Full Text PDFAnal Sci
December 2003
National Environmental Research and Training Institute, Ministry of the Environment, 3-3 Namiki, Tokorozawa, Saitama 359-0042, Japan.
A highly sensitive and selective method based on alkaline digestion for the simultaneous determination of bisphenol A (BPA) and 4-nonylphenol (NP) was developed. The method consists of digestion of the matrix with ethanolic KOH, extraction with diethyl ether under a mild alkaline condition, cleaning with successive aminopropyl (NH2) cartridges and derivatization followed by a GC-MS analysis. The assay accuracies, expressed as recoveries, were 82 - 113% for BPA and 89 - 97% for NP.
View Article and Find Full Text PDF