215 results match your criteria: "NIHR Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust[Affiliation]"

Assessment of the accuracy of AortaScan for detection of abdominal aortic aneurysm (AAA).

Eur J Vasc Endovasc Surg

February 2012

King's College London British Heart Foundation Centre of Research Excellence, Academic Department of Surgery, Cardiovascular Division, NIHR Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust and King's College Hospital, London SE1 7EH, UK.

Background: AortaScan AMI 9700 is a portable 3D ultrasound device that automatically measures the maximum diameter of the abdominal aorta without the need for a trained sonographer. It is designed to rapidly diagnose or exclude an AAA and may have particular use in screening programs. Our objective was to determine its accuracy to detect AAA.

View Article and Find Full Text PDF

Advances in imaging for atrial fibrillation ablation.

Radiol Res Pract

November 2011

Cardiovascular Division, Kings College London BHF Centre, NIHR Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, London WC2R 2LS, UK.

Over the last fifteen years, our understanding of the pathophysiology of atrial fibrillation (AF) has paved the way for ablation to be utilized as an effective treatment option. With the aim of gaining more detailed anatomical representation, advances have been made using various imaging modalities, both before and during the ablation procedure, in planning and execution. Options have flourished from procedural fluoroscopy, electroanatomic mapping systems, preprocedural computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and combinations of these technologies.

View Article and Find Full Text PDF

Successful expansion of functional CD4(+) CD25(+) regulatory T cells (T(reg)) ex vivo under good manufacturing practice conditions has made T(reg) -cell therapy in clinical transplant tolerance induction a feasible possibility. In animals, T(reg) cells home to both transplanted tissues and local lymph nodes and are optimally suppressive if active at both sites. Therefore, they have the opportunity to suppress both naïve and memory CD4(+) CD25(-) T cells (Tresp).

View Article and Find Full Text PDF

Introduction: Venous thrombus resolution may be regulated by an angiogenic process that involves the surrounding vein wall. The aims of this study were to determine whether: (i) thrombosis stimulates activation of the angiogenic transcription factor, hypoxia-inducible factor (HIF) 1α, and downstream expression of growth factors in vein wall; and (ii) upregulation of HIF1α in vein wall leads to increased growth factor expression and enhanced thrombus resolution.

Materials And Methods: HIF1α, vascular endothelial growth factor (VEGF), and placental growth factor (PLGF) were quantified in mouse inferior vena cava (IVC) at days 1, 3, 7, and 14 after thrombus formation (n = 10-13 per group).

View Article and Find Full Text PDF

Late gadolinium enhancement (LGE) is widely used to precisely localize and determine the extent and transmurality of myocardial scarring. Performing LGE imaging at end-systole may reduce motion artefacts. It is therefore important to know whether end-systolic imaging influences infarct transmurality in patients with ischemic scar.

View Article and Find Full Text PDF

High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenoses as determined by fractional flow reserve.

J Am Coll Cardiol

January 2011

Cardiovascular Division, King's College London BHF Centre of Excellence, and NIHR Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust, The Rayne Institute, St. Thomas' Hospital, London, United Kingdom.

Objectives: The objective of this study was to compare visual and quantitative analysis of high spatial resolution cardiac magnetic resonance (CMR) perfusion at 3.0-T against invasively determined fractional flow reserve (FFR).

Background: High spatial resolution CMR myocardial perfusion imaging for the detection of coronary artery disease (CAD) has recently been proposed but requires further clinical validation.

View Article and Find Full Text PDF

Purpose: To evaluate a cardiac MR (CMR) examination with slow infusion of a high-relaxivity contrast agent to visualize coronary venous anatomy (CVA) and myocardial scar in heart failure patients awaiting cardiac resynchronization therapy (CRT).

Materials And Methods: Fourteen patients awaiting CRT (seven ischemic cardiomyopathy (ICM) and seven non-ICM) and two with normal LV function underwent CMR on a 1.5 Tesla (T) MR scanner.

View Article and Find Full Text PDF

Background: Percutaneous cardiac interventions are currently performed under x-ray guidance. Magnetic resonance imaging (MRI) has been used to guide intravascular interventions in the past, but mainly in animals. Translation of MR-guided interventions into humans has been limited by the lack of MR-compatible and safe equipment, such as MR guide wires with mechanical characteristics similar to standard guide wires.

View Article and Find Full Text PDF

Background: Failure rate for left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is up to 12%. The use of segmentation tools, advanced image registration software, and high-fidelity images from computerized tomography (CT) and cardiac magnetic resonance (CMR) of the coronary sinus (CS) can guide LV lead implantation. We evaluated the feasibility of advanced image registration onto live fluoroscopic images to allow successful LV lead placement.

View Article and Find Full Text PDF

Transcriptional regulation of the mucosal immune system mediated by T-bet.

Mucosal Immunol

November 2010

National Institute for Health Research (NIHR) Comprehensive Biomedical Research Centre at Guy's and St Thomas' NHS Foundation Trust, Guy's Hospital, King's College London, London, UK.

The immune system faces the arduous task of defending the mucosal surfaces from invading pathogens, but must simultaneously repress responses against commensal organisms and other inert antigens that are abundant in the external environment, as inappropriate immune activation might expose the host to increased risk of autoimmunity. The behavior of individual immune cells is governed by the expression of transcription factors that are responsible for switching immune response genes on and off. T-bet (T-box expressed in T cells) has emerged as one of the key transcription factors responsible for controlling the fate of both innate and adaptive immune cells, and its expression in different immune cells found at mucosal surfaces is capable of dictating the critical balance between permitting robust host immunity and limiting susceptibility to autoimmunity and allergy.

View Article and Find Full Text PDF

Importance Of The Field: Mesenchymal stem cells are multipotent adult stem cell populations that have broad differentiation plasticity and immunosuppressive potential that render them of great importance in cell-based therapies. They are identified by in vitro characteristics based on their differentiation potential for clinical approaches while their biological properties and in vivo identities are often less understood.

Areas Covered In This Review: Recent research carried out in the last decade on mesenchymal stem cell biology suggests that mesenchymal stem cells from various tissues reside in a perivascular location and these can be identified as pericytes that function as mural cells in microvessels.

View Article and Find Full Text PDF

Mycotic aortic aneurysms are rare and it is unlikely that any center will obtain extensive experience in their management. The aim of treatment is to repair the aorta and eradicate the infection with minimal operative and postoperative risk. We describe a case in which a custom-made endovascular stent graft provided the optimal treatment strategy and remained durable at 4 years of follow-up.

View Article and Find Full Text PDF

Purpose: To investigate the impact of interinstitutional variance (=interobserver variance between institutions) for volumetric and flow cardiac MR (CMR) data and if training on image reading could improve bias.

Materials And Methods: In a three-center study, a total of 32 adults with repaired Tetralogy of Fallot and 23 controls underwent CMR using standardized protocols for ventricular volumes/mass (by transverse and short-axis cine-MRI) and pulmonary/aortic blood flow by velocity-encoded MRI (VEC-MRI). Data were analyzed blinded and independently in each institution by experienced readers.

View Article and Find Full Text PDF

A crucial requirement in MR-guided interventions is the visualization of catheter devices in real time. However, true 3D visualization of the full length of catheters has hitherto been impossible given scan time constraints. Compressed sensing (CS) has recently been proposed as a method to accelerate MR imaging of sparse objects.

View Article and Find Full Text PDF