26 results match your criteria: "Medanta Cancer institute[Affiliation]"
Cureus
December 2024
Department of Medical Affairs, Dr. Reddy's Laboratories, Hyderabad, IND.
This research aims to optimize adjuvant ovarian function suppression (OFS) for premenopausal Indian women with hormone receptor-positive (HR+) /human epidermal growth factor receptor 2-negative (HER2-) early breast cancer (eBC). To address specific challenges identified in clinical practice, a comprehensive questionnaire consisting of 21 statements was developed. These statements were reviewed and validated by a scientific committee, ensuring their accuracy and relevance to the study's objectives.
View Article and Find Full Text PDFHum Vaccin Immunother
August 2023
GSK, Mumbai, India.
Immunocompromised (IC) populations are at increased risk of vaccine-preventable diseases (VPDs). In India, the concern of VPDs in IC populations is particularly acute due to the prevalence of crowded living situations, poor sanitation and variable access to healthcare services. We present a narrative review of IC-related disease and economic burden, risk of VPDs and vaccination guidelines, based on global and India-specific literature (2000-2022).
View Article and Find Full Text PDFAsian Pac J Cancer Prev
April 2023
Division of Radiation Oncology, Medanta Cancer Institute, Medanta The Medicity, Gurgaon, Haryana, India.
Objective: The aim of this study is to makethe standard total body irradiation (TBI) protocol for Helical tomotherapy© (HT) and to analyze the optimal pitch and modulation factor (MF) with respect to dose homogeneity index (HI), target dose coverage, target overdose, beam on time (BOT) and mean lung dose.
Materials And Methods: Ten patients who underwent high-dose TBI were taken for this study. For each patient, 35 dose plans were created by different combination of pitch and MF.
J Med Phys
January 2023
Division of Radiation Oncology, Medanta Cancer Institute, Medanta the Medicity, Gurgaon, Haryana, India.
Aim: The goal of this study is to discuss the commissioning and dosimetric parameters achieved during the clinical implementation of an indigenously developed intracavitary (IC) plus interstitial (IS) template for high dose rate (HDR) image-guided brachytherapy (IGBT) in cancer (Ca) cervix. We want to discuss our achieved values of cumulative equi-effective doses (EQD2) for high-risk clinical target volume (HRCTV) and organ at risk (OAR) and compare it with available published results.
Materials And Methods: Medanta anterior oblique/lateral oblique template has a total of 19 needles including the central tandem.
J Radiosurg SBRT
January 2022
Division of Radiation Oncology, Medanta Cancer Institute, Medanta the Medicity, Gurgaon, India.
Ocul Immunol Inflamm
April 2023
Department of Uvea & Intraocular Inflammation, Medical Research Foundation, Sankara Nethralaya, Chennai, India.
Purpose: To describe a case of retinal vascular occlusion and cerebrovascular accident following axitinib therapy.
Methods: A retrospective chart review.
Result: A 65-year-old gentleman with a history of renal cell carcinoma and subsequent metastases to the brain was on axitinib at an oral daily dose of 10 mg.
South Asian J Cancer
January 2021
Department of Medical Oncology, Tata Memorial Hospital/Center, Mumbai, Maharashtra, India.
Coronavirus pandemic has increased human disease burden, as well as economic distress globally. Being in an immunocompromised state, patients with cancer comprise an important at-risk population for novel coronavirus disease 2019 (COVID-19) infection. It is necessary to modify individualized clinical management for every cancer patient in the context of the ongoing COVID-19 pandemic.
View Article and Find Full Text PDFJ Med Phys
May 2021
Division of Radiation Oncology, Medanta Cancer Institute, Medanta The Medicity, Gurgaon, Haryana, India.
Purpose: To investigate the dosimetric comparison of different collimators which are used in robotic radiosurgery (cyberknife-CK) and linear accelerator (LINAC) for stereotactic radiosurgery (SRS) in arteriovenous malformation (AVM).
Materials And Methods: Twenty-five AVM patients were planned in CK using FIXED cone, IRIS collimator, and multi-leaf collimator (MLC) based in LINAC. Dosimetric comparison was performed using Paddick conformity index (CI) and International Commission on Radiation Units and measurements (ICRU) homogeneity index (HI), gradient score (GS), normal brain dose received by 10cc (D) and critical structure (brain stem, optic chiasma, optic nerves) doses.
Int J Oncol
February 2021
Department of Medical Affairs, Oncology, AstraZeneca Pharma India Ltd., Bangalore, Karnataka 560045, India.
A substantial (40‑60%) proportion of patients with non‑small cell lung carcinoma (NSCLC) have epidermal growth factor receptor (EGFR) mutations, a crucial therapeutic target in NSCLC. Treatment strategies for patients with advanced‑stage NSCLC have markedly changed, from the empirical use of cytotoxic agents to targeted regimens. EGFR tyrosine kinase inhibitors (TKIs), the first‑line therapy for advanced NSCLC, are reported to be the most effective.
View Article and Find Full Text PDFCureus
November 2020
Division of Radiation Oncology, Medanta Cancer Institute, Medanta The Medicity, Gurugram, IND.
Introduction: Stereotactic body radiation therapy (SBRT) is increasingly being utilized to deliver escalated radiation doses for improving outcomes in various malignancies. We analyzed our cohort of locally advanced, node-positive, and bone oligometastatic prostate cancer patients, that were treated with a combination of pelvic RT using conventional fractionation (CF) and SBRT boost to prostate using extreme hypofractionation (EH), along with hormone therapy (HT).
Materials And Methods: Outcomes of 44 prospectively treated patients were analyzed.
J Cancer Res Clin Oncol
November 2020
Department of Environmental Health Sciences, Florida International University, Miami, USA.
Background: The anthracycline and taxane-based chemotherapy treatment regimen remains the gold standard for treatment of early stage breast cancer. However, studies examining the effectiveness and use of this treatment regimen in Indian context are limited. This study examined patients treated with anthracycline and taxane-based chemotherapy at a tertiary care cancer center in India.
View Article and Find Full Text PDFAuris Nasus Larynx
February 2018
Department of Head and Neck Oncosurgery Medanta Cancer Institute, Medanta-The Medicity Gurgaon, India.
Objective: To evaluate the incidence of level IIB and IV lymph node metastases in patients of oral carcinoma with N0 necks. This study will help to decide the extent and need of routine comprehensive removal of these specific lymph node groups in selective neck dissection.
Methods: Prospective analytical study of 231 patients of oral carcinoma with N0 necks undergoing neck dissections were prospectively analyzed.
Br J Radiol
December 2016
1 Division of Radiation Oncology, Medanta Cancer Institute, Medanta-The Medicity, Gurgaon, Haryana, India.
Stereotactic body radiotherapy (SBRT) is being increasingly utilized in the treatment of prostate cancer. With the advent of high-precision radiosurgery systems, it is possible to obtain dose distributions akin to high-dose rate brachytherapy with SBRT. However, urethral toxicity has a significant impact on the quality of life in patients with prostate cancer.
View Article and Find Full Text PDFIndian J Cancer
April 2017
Division of Radiation Oncolgy, Medanta Cancer Institute, Medanta - The Medicity, Gurgaon, Haryana, India.
Aim: Patient satisfaction is increasingly being identified as an important benchmark in health care industry. Studies addressing patients' perceptions of quality are available but there is paucity of data regarding the perception of health care providers towards their own services. This study was undertaken to compare the satisfaction level between the patients and the staff from a Radiation Oncology Department.
View Article and Find Full Text PDFJ Med Phys
April 2016
Department of Physics, School of Advanced Sciences, VIT University, Vellore, Tamil Nadu, India.
Organ motions during inter-fraction and intra-fraction radiotherapy introduce errors in dose delivery, irradiating excess of normal tissue, and missing target volume. Lung and heart involuntary motions cause above inaccuracies and gated dose delivery try to overcome above effects. Present work attempts a novel method to verify dynamic dose delivery using a four-dimensional (4D) phantom.
View Article and Find Full Text PDFLaryngoscope
October 2016
Department of Head and Neck Oncosurgery, Medanta Cancer Institute, Medanta-The Medicity, Gurgaon, India.
Objectives/hypothesis: The incidence of occult perifacial nodal disease in oral cavity squamous cell carcinoma is not well reported. The purpose of this study was to evaluate the incidence of isolated perifacial lymph node metastasis in patients with oral squamous cell carcinoma with a clinically node-negative neck. The study will shed light on current controversies and will provide valuable clinical and pathological information in the practice of routine comprehensive removal of these lymph node pads in selective neck dissection in the node-negative neck.
View Article and Find Full Text PDFRep Pract Oncol Radiother
February 2016
Medical Physics Division, Dept of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, Delhi, India.
Aim: The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.
View Article and Find Full Text PDFJ Radiosurg SBRT
January 2016
Division of Radiation Oncology, Medanta Cancer institute, Medanta The Medicity, Sector 38, Gurgaon, Haryana, 122001, India.
Purpose: Analysis of intrafraction motion in patients with intracranial targets treated with frameless, mask based stereotactic radiosurgery / radiotherapy using standard couch and 6D-skull tracking on CyberKnife.
Materials And Methods: Twenty-seven treatment datasets of fifteen patients were analyzed. For each sequential pair of images, the correction to the target position (position "offset") in six-degrees of motion was obtained.
Radiol Res Pract
January 2015
Division of Radiation Oncology, Medanta Cancer Institute, Medanta-The Medicity, Gurgaon, Haryana 122001, India.
In modern day radiotherapy, the emphasis on reduction on volume exposed to high radiotherapy doses, improving treatment precision as well as reducing radiation-related normal tissue toxicity has increased, and thus there is greater importance given to accurate position verification and correction before delivering radiotherapy. At present, several techniques that accomplish these goals impeccably have been developed, though all of them have their limitations. There is no single method available that eliminates treatment-related uncertainties without considerably adding to the cost.
View Article and Find Full Text PDFAm J Otolaryngol
November 2015
Division of Radiation Oncology, Medanta Cancer Institute, Medanta The Medicity, Gurgaon, Haryana, India.
Aims: To evaluate the efficacy and toxicity of concurrent chemoradiation in patients with head and neck cancers aged 65 and older.
Materials And Methods: Thirty-two elderly patients were treated with radical chemoradiation. Twenty-six (81.
Clin Colorectal Cancer
September 2014
Department of Oncology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea. Electronic address:
Colorectal cancer (CRC) is among the most common cancers worldwide, but marked epidemiological differences exist between Asian and non-Asian populations. Hence, a consensus meeting was held in Hong Kong in December 2012 to develop Asia-specific guidelines for the management of metastatic CRC (mCRC). A multidisciplinary expert panel, consisting of 23 participants from 10 Asian and 2 European countries, discussed current guidelines for colon or rectal cancer and developed recommendations for adapting these guidelines to Asian clinical practice.
View Article and Find Full Text PDFJ Contemp Brachytherapy
June 2013
Medanta Cancer Institute, Medanta - The Medicity.
Purpose: Malignant obstructive jaundice (MOJ) is relieved by stenting via endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography and biliary drainage (PTCD). Stent occlusion rates of 30-45% have been reported in literature due to tumor ingrowth or overgrowth. We prospectively evaluated the feasibility and the role of intraluminal brachytherapy (ILBT) in preventing stent blockage in patients with MOJ after PTCD and stenting.
View Article and Find Full Text PDFNeurol India
September 2013
Division of Radiation Oncology, Medanta Cancer Institute, Gurgaon, Haryana, India.
Purpose: To assess the setup errors and intrafraction motion in patients treated with frame-based and frameless stereotactic radiosurgery (SRS).
Materials And Methods: Ten patients treated with frame-based and six patients treated with frameless radiosurgery were prospectively enrolled in the study. Leksell frame was used for frame-based and a customized uniframe orfit cast for frameless techniques.
J Med Phys
October 2012
Division of Radiation Oncology, Medanta Cancer Institute, Medanta- The Medicity, Sector- 38, Gurgaon, Haryana, India.
Homogeneity Index (HI) is an objective tool to analyz the uniformity of dose distribution in the target volume. Various formulae have been described in literature for its calculation but there is paucity of data regarding the ideal formula and the factors affecting this index. This study was undertaken to analyze HI in our patients using various formulae and to find out the co-relation between HI and prescribed dose, target volume and target location.
View Article and Find Full Text PDF