7 results match your criteria: "MR Research Center (MRRC)[Affiliation]"
NMR Biomed
November 2015
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), New Haven, CT, USA.
To date, spatial encoding for MRI is based on linear X, Y and Z field gradients generated by dedicated X, Y and Z wire patterns. We recently introduced the dynamic multi-coil technique (DYNAMITE) for the generation of magnetic field shapes for biomedical MR applications from a set of individually driven localized coils. The benefits for B0 magnetic field homogenization have been shown, as well as proof of principle of radial and algebraic MRI.
View Article and Find Full Text PDFNeuroimage
January 2015
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC).
View Article and Find Full Text PDFNMR Biomed
August 2014
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), New Haven, CT, USA.
The in vivo rat model is a workhorse in neuroscience research, preclinical studies and drug development. A repertoire of MR tools has been developed for its investigation; however, high levels of B0 magnetic field homogeneity are required for meaningful results. The homogenization of magnetic fields in the rat brain, i.
View Article and Find Full Text PDFJ Magn Reson
November 2013
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA. Electronic address:
The performance of multi-coil (MC) magnetic field modeling is compared to dedicated wire patterns for the generation of spherical harmonic (SH) shapes as these are the workhorse for spatial encoding and magnetic field homogenization in MR imaging and spectroscopy. To this end, an example 48 channel MC setup is analyzed and shown to be capable of generating all first through fourth order SH shapes over small and large regions-of-interest relevant for MR investigations. The MC efficiency for the generation of linear gradient fields shares the same order of magnitude with classic and state-of-the-art SH gradient coils.
View Article and Find Full Text PDFJ Magn Reson
October 2011
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), New Haven, CT 06520, USA.
High quality magnetic field homogenization of the human brain (i.e. shimming) for MR imaging and spectroscopy is a demanding task.
View Article and Find Full Text PDFMagn Reson Med
September 2011
Department of Diagnostic Radiology, Yale University School of Medicine, MR Research Center (MRRC), New Haven, Connecticut 06520, USA.
MR imaging and spectroscopy allow the noninvasive measurement of brain function and physiology, but excellent magnetic field homogeneity is required for meaningful results. The homogenization of the magnetic field distribution in the mouse brain (i.e.
View Article and Find Full Text PDFJ Magn Reson
June 2010
Yale University School of Medicine, Department of Diagnostic Radiology, MR Research Center (MRRC), 300 Cedar Street, New Haven, CT 06520, USA.
A set of generic, circular individual coils is shown to be capable of generating highly complex magnetic field distributions in a flexible fashion. Arbitrarily oriented linear field gradients can be generated in three-dimensional as well as sliced volumes at amplitudes that allow imaging applications. The multi-coil approach permits the simultaneous generation of linear MRI encoding fields and complex shim fields by the same setup, thereby reducing system complexity.
View Article and Find Full Text PDF