11 results match your criteria: "Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center[Affiliation]"
Clin Ophthalmol
December 2024
Department of Refractive Surgery, Eye Clinic Sistina Oftalmologija, Skopje, 1000 Republic of North Macedonia.
Purpose: To explore the significance of changes in anterior chamber depth (ΔACD) and astigmatism between 4 and 8 weeks following uneventful phacoemulsification.
Patients And Methods: Anterior chamber depth (ACD, mm), autorefractometry and subjective refraction were monitored in pseudophakic eyes implanted with non-toric IOLs (group 1, SA60AT, n=36; group 2, SN60WF, n=34; group 3, ICBOO, n=16) and phakic control group (n=30, group 4a, for ACD and autorefractometry) over four weeks. Changes in subjective refractions were compared with repeatability in normal phakic eyes (n=30, group 4b).
Am J Ophthalmol
November 2024
Institute for Research in Ophthalmology (A.G.), Foundation for Ophthalmology Development, Poznan, Poland; Department of Ophthalmology (A.G.), University of Warmia and Mazury, Olsztyn, Poland. Electronic address:
Purpose: To compare 7 artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in extremely long eyes.
Design: Retrospective accuracy and validity analysis.
Setting: Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Ukraine.
Purpose: To compare the accuracy of 16 intraocular lens (IOL) power calculation formulas in pediatric cataract eyes.
Patients And Methods: The data records of pediatric patients who had been implanted with three IOL models (SA60AT, MA60AC, and enVista-MX60) between 2012 and 2018 were analyzed. The accuracy of 16 IOL power calculation methods was evaluated: Barrett Universal II (BUII), Castrop, EVO 2.
Eye (Lond)
October 2024
Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Komarov Ave. 3, Medical City, Kyiv, 03680, Ukraine.
Background: To investigate the accuracy of the VRF-L and VRF-GL IOL power calculation methods in cataract surgery after radial keratotomy (RK).
Methods: The VRF-L and VRF-GL methods were collated with nine formulas: Barrett True K (No History), Haigis, Hoffer Q, Hoffer Q (Double-K), Holladay 1 (Double-K), Holladay 2 (Double-K), PEARL-DGS (RK), SRK/T (Double-K), and T2 (Double-K). With SS-OCT biometry (IOLMaster 700, Carl Zeiss Meditec), data of 78 eyes from 78 patients with previous RK was included.
Ophthalmol Ther
July 2024
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553, Poznan, Poland.
Introduction: The aim of this work is to compare 20 intraocular lens (IOL) power calculation formulas in medium-long eyes (24.50-25.99 mm) in terms of root mean square absolute error (RMSAE), median absolute error (MedAE), and percentage of eyes with prediction error (PE) within ± 0.
View Article and Find Full Text PDFClin Ophthalmol
November 2023
Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Komarov Ave. 3, Medical City, 03680, Kyiv, Ukraine.
Purpose: To collate the accuracy of two recently introduced intraocular lens (IOL) formulas (VRF and VRF-G) in cataract patients using a swept-source optical coherence tomography (SS-OCT) biometry (IOL Master 700, Carl Zeiss Meditec AG, Jena, Germany).
Patients And Methods: Data records of 295 eyes from 295 patients were included in this scrutiny. The IOLMaster 700 SS-OCT biometer was used for biometric measurements.
Graefes Arch Clin Exp Ophthalmol
September 2023
Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Medical City, Komarov Ave. 3, Kiev, 03680, Ukraine.
Purpose: To investigate the accuracy of modern intraocular lens (IOL) power calculation formulas in eyes with axial length (AL) ≥ 26.00 mm.
Methods: A total of 193 eyes with one type of lens were analysed.
Graefes Arch Clin Exp Ophthalmol
December 2022
Bristol Eye Hospital, University Hospitals Bristol NHS Foundation Trust, Lower Maudlin St, Bristol, BS1 2LX, UK.
Purpose: Accurate intraocular lens (IOL) calculation in subjects with irregular astigmatism is challenging. This study evaluated the accuracy of using Scheimpflug-derived central 2-mm equivalent keratometry reading (EKR) values for IOL calculation in irregular astigmatism.
Methods: This retrospective study included subjects (31 eyes of 30 patients) who underwent cataract surgery and IOL calculation using the 2-mm central EKR methods.
Eye (Lond)
January 2023
Department of Ophthalmology, Centro Hospitalar Universitário De Lisboa Central, Lisbon, 1169-050, Portugal.
Background: To compare the accuracy of recently developed modern intraocular lens (IOL) power formulas (Barrett Universal II, Kane and VRF-G) with existing IOL power formulas in eyes with an axial length (AL) ≤ 22 mm.
Methods: This analysis comprised 172 eyes of 172 patients operated on by one surgeon (LT) with one IQ SN60WF (Alcon Labs, Fort Worth, TX, USA) hydrophobic lens. Ten IOL formulas were evaluated: Barrett Universal II (BUII), Haigis, Hoffer Q, Holladay 1, Holladay 2, Kane, SRK/T, T2, VRF and VRF-G.
Curr Eye Res
December 2021
Department of Ophthalmology, Centro Hospitalar Universitário De Lisboa Central, Lisbon, Portugal.
Purpose: To analyze the accuracy of 18 intraocular lens (IOL) power calculation formulas in eyes with axial length (AL) ≤ 22 mm.
Methods: We analyzed 241 eyes of 241 patients. Eighteen formulas were evaluated: Barrett Universal II (BUII), EVO 2.
Clin Ophthalmol
December 2020
Department of Ophthalmology, Centro Hospitalar Universitário De Lisboa Central, Lisbon 1169-050, Portugal.
Purpose: To compare the accuracy of a newly developed intraocular lens (IOL) power formula (VRF-G) with twelve existing formulas (Barret Universal II, EVO 2.0, Haigis, Hill-RBF 2.0, Hoffer Q, Holladay 1, Kane, Næeser 2, PEARL-DGS, SRK/T, T2 and VRF).
View Article and Find Full Text PDF