474 results match your criteria: "Institute of Radiation Physics[Affiliation]"

Purpose: Treatment planning for CyberKnife (CK) (Accuray, USA) can be performed with Precision (Accuray, USA) or RayStation (RS) (RaySearch Laboratories, Sweden) treatment planning systems (TPS). RaySearch recently released a new version of the CK module in RS 12A. The objective of the study was to compare plan quality between RS 12A and Precision.

View Article and Find Full Text PDF

A new method to assess the performance of anti-scatter grids in x-ray projection imaging.

Biomed Phys Eng Express

December 2024

Institute of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Rue du Grand-Pré 1, 1007 Lausanne, Switzerland.

This work proposes a new method to assess the performance of radiographic anti-scatter grids (ASGs) without the use of a narrow primary beam, which is difficult to achieve.Three general purpose ASGs were evaluated, two marketed ASGs and a low frequency and high ratio prototype ASG with molybdenum lamellae. A range of high scatter x-ray beams were used in a standardized geometry, with energies ranging from 60 kV to 121 kV, for five beam sizes between 10 × 10 and 30 × 30 cm.

View Article and Find Full Text PDF

Background: The radiation exposure of nuclear medicine personnel, especially concerning extremity doses, has been a significant focus over the past two decades. This study addresses the evolving practice of NM, particularly with the rise of radionuclide therapy and theranostic procedures, which involve a variety of radionuclides such as Ga, Lu, and I. Traditional studies have concentrated on common radioisotopes like Tc, F, and Y, but there is limited data on these radionuclides, which are more and more frequently used.

View Article and Find Full Text PDF

Proton bunch monitors for the clinical translation of prompt gamma-ray timing.

Phys Med Biol

November 2024

OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.

. Prompt gamma-ray timing is an emerging technology in the field of particle therapy treatment verification. This system measures the arrival times of gamma rays produced in the patient body and uses the cyclotron radio frequency signal as time reference for the beam micro-bunches.

View Article and Find Full Text PDF

Ultra-high dose rate FLASH radiotherapy, a promising cancer treatment approach, offers the potential to reduce healthy tissue damage during radiotherapy. As the mechanisms underlying this process remain unknown, several hypotheses have been proposed, including the altered production of radio-induced species under ultra-high dose rate (UHDR) conditions. This study explores realistic irradiation scenarios with various dose-per-pulse and investigates the role of pulse temporal structure.

View Article and Find Full Text PDF

Background And Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s.

View Article and Find Full Text PDF

In this paper, we demonstrate the successful implementation of reconfigurable field-programmable gate array technology into a pulse-resolved data acquisition system to achieve a femtosecond temporal resolution in ultrafast pump-probe experiments in real-time at large scale facilities. As proof of concept, electro-optic sampling of terahertz waveforms radiated by a superradiant emitter of a quasi-cw accelerator operating at a 50 kHz repetition rate and probed by an external laser system is performed. Options for up-scaling the developed technique to a MHz range of repetition rates are discussed.

View Article and Find Full Text PDF

This study is the first one that investigates in detail the bacterial intercellular response to the high density of crystallographic defects including vacancies created in Cu by high pressure torsion. To this aim, samples were deformed by high pressure torsion and afterward, their antibacterial properties against Staphylococcus aureus were analyzed in adhesion tests. As a reference an annealed sample was applied.

View Article and Find Full Text PDF

The vast repository of van der Waals (vdW) materials supporting polaritons offers numerous possibilities to tailor electromagnetic waves at the nanoscale. The development of twistoptics-the modulation of the optical properties by twisting stacks of vdW materials-enables directional propagation of phonon polaritons (PhPs) along a single spatial direction, known as canalization. Here we demonstrate a complementary type of directional propagation of polaritons by reporting the visualization of unidirectional ray polaritons (URPs).

View Article and Find Full Text PDF

Purpose: This study explores the dosimetric feasibility and plan quality of hybrid ultra-high dose rate (UHDR) electron and conventional dose rate (CDR) photon (HUC) radiotherapy for treating deep-seated tumours with FLASH-RT.

Methods: HUC treatment planning was conducted optimizing a broad UHDR electron beam (between 20-250 MeV) combined with a CDR VMAT for a glioblastoma, a pancreatic cancer, and a prostate cancer case. HUC plans were based on clinical prescription and fractionation schemes and compared against clinically delivered plans.

View Article and Find Full Text PDF
Article Synopsis
  • Radiopharmaceutical theranostic treatments are becoming increasingly popular for cancer therapy, especially for CNS tumors, and rely on the internal release of radiation to achieve clinical effects.
  • Accurate absorbed dose calculations are crucial for understanding how the treatment works and customizing it for individual patients.
  • The article emphasizes the advancements in internal dosimetry techniques, the importance of consistent data collection for treatment planning, and the challenges faced in applying these methods effectively.
View Article and Find Full Text PDF

HO transforms to two forms of superionic (SI) ice at high pressures and temperatures, which contain highly mobile protons within a solid oxygen sublattice. Yet the stability field of both phases remains debated. Here, we present the results of an ultrafast X-ray heating study utilizing MHz pulse trains produced by the European X-ray Free Electron Laser to create high temperature states of HO, which were probed using X-ray diffraction during dynamic cooling.

View Article and Find Full Text PDF

Photon-counting CT systems: A technical review of current clinical possibilities.

Diagn Interv Imaging

September 2024

University of Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621 Villeurbanne, France; Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France.

In recent years, computed tomography (CT) has undergone a number of developments to improve radiological care. The most recent major innovation has been the development of photon-counting detectors. By comparison with the energy-integrating detectors traditionally used in CT, these detectors offer better dose efficiency, eliminate electronic noise, improve spatial resolution and have intrinsic spectral sensitivity.

View Article and Find Full Text PDF

In vivo measurements of change in tissue oxygen level during irradiation reveal novel dose rate dependence.

Radiother Oncol

December 2024

Radiation Oncology Laboratory, Department of Radiation Oncology, Lausanne, University Hospital and University of Lausanne, Lausanne, Switzerland; Radiotherapy and Radiobiology Sector, Radiation Therapy Service, University Hospital of Geneva, Geneva, Switzerland; LiRR- Laboratory of Innovation in Radiobiology Applied to Radiotherapy, Faculty of Medicine, University of Geneva, Geneva, Switzerland.

Background And Purpose: This study aimed to investigate the radiochemical oxygen depletion (ROD) in vivo by directly measuring oxygen levels in various mouse tissues during ultra-high dose rate (UHDR) irradiation at clinically relevant doses and dose rates.

Materials And Methods: Mice bearing subcutaneous human glioblastoma (U-87 MG) tumors were used for tumor and normal tissue (skin, muscle, brain) measurements. An oxygen-sensitive phosphorescent probe (Oxyphor PtG4) was injected into the tissues, and oxygen levels were monitored using a fiberoptic phosphorometer during UHDR irradiation with a 6 MeV electron linear accelerator (LINAC).

View Article and Find Full Text PDF

The system of radiological protection and the UN sustainable development goals.

Radiat Environ Biophys

November 2024

Centre for Radiation Protection Research, Stockholm University, Svante Arrheniusväg 20C, Stockholm, 106 91, Sweden.

In 2015 the United Nations issued 17 Sustainable Development Goals (SDGs) addressing a wide range of global social, economic, and environmental challenges. The main goal of this paper is to provide an understanding of how the current System of Radiological Protection relates to these SDGs. In the first part it is proposed that the current System of Radiological Protection is implicitly linked to sustainable development.

View Article and Find Full Text PDF

Recording and reporting of ultra-high dose rate "FLASH" delivery for preclinical and clinical settings.

Radiother Oncol

November 2024

National Physical Laboratory, Hampton Road, Teddington TW11 0LW, UK; University College London, Gower Street, London WC1E 6BT, UK. Electronic address:

Treatments at ultra-high dose rate (UHDR) have the potential to improve the therapeutic index of radiation therapy (RT) by sparing normal tissues compared to conventional dose rate irradiations. Insufficient and inconsistent reporting in physics and dosimetry of preclinical and translational studies may have contributed to a reproducibility crisis of radiobiological data in the field. Consequently, the development of a common terminology, as well as common recording, reporting, dosimetry, and metrology standards is required.

View Article and Find Full Text PDF

Background: Transarterial radio-embolization (TARE) became a routine procedure for non-resectable liver tumor mainly hepatocellular carcinoma (HCC). Personalized dosimetry to the index lesion increased tumor response rate. However, there is no requirement to measure the precise activity injected during TARE.

View Article and Find Full Text PDF

Stereotactic radio-neurosurgery for jugular foramen schwannomas.

Acta Neurochir (Wien)

August 2024

Neurosurgery Service and Gamma Knife Center, Lausanne University Hospital (CHUV), Rue du Bugnon 44-46, BH-08, CH-1011, Lausanne, Switzerland.

Background: Stereotactic radiosurgery (SRS) represents a minimally invasive and valuable alternative for jugular foramen schwannomas (JFS), both as upfront and/or adjuvant treatment (in hybrid approaches).

Methods: We conducted a retrospective review of our cases treated at the Lausanne University Hospital (CHUV) from June 2010 to October 2023. Eleven patients underwent SRS, among whom three had prior surgery, two in our center in the frame of a planned combined approach and one in another center.

View Article and Find Full Text PDF

Background: Treatment delivery safety and accuracy are essential to control the disease and protect healthy tissues in radiation therapy. For usual treatment, a phantom-based patient specific quality assurance (PSQA) is performed to verify the delivery prior to the treatment. The emergence of adaptive radiation therapy (ART) adds new complexities to PSQA.

View Article and Find Full Text PDF

Dual-Split CT to Simulate Multiple Radiation Doses From a Single Scan-Liver Lesion Detection Compared With Dose-Matched Single-Energy CT.

Invest Radiol

July 2024

From the Institute of Radiation Physics, University Hospital Lausanne (CHUV), University of Lausanne, Lausanne, Switzerland (D.R., L.G.M., A.V.); Department of Radiology, Kantonsspital Baden, Affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland (T.N., R.A.K.-H., A.E.); Department of Biomedical Imaging and Image-Guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Vienna, Austria (B.N.); and Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (H.A., T.F.).

Objectives: The aim of this study was to evaluate the potential use of simulated radiation doses from a dual-split CT scan for dose optimization by comparing their lesion detectability to dose-matched single-energy CT acquisitions at different radiation dose levels using a mathematical model observer.

Materials And Methods: An anthropomorphic abdominal phantom with liver lesions (5-10 mm, both hyperattenuating and hypoattenuating) was imaged using a third-generation dual-source CT in single-energy dual-source mode at 100 kVp and 3 radiation doses (5, 2.5, 1.

View Article and Find Full Text PDF

The role of defect charge, crystal chemistry, and crystal structure on positron lifetimes of vacancies in oxides.

J Phys Condens Matter

August 2024

Materials Science and Technology Division, Los Alamos National Laboratory, Los Alamos, NM 87545, United States of America.

Density functional theory based positron lifetime (PL) calculations for cation and oxygen monovacancies in a range of oxides-hematite, magnetite, hercynite, and alumina-have been conducted to compare the impact of defect chemistry and crystal structure on the predicted lifetimes. The role of defect charge state has also been examined. A comparison across the same type of crystalline structure but different composition shows that oxygen vacancies only induce a slight increase in the positron-electron overlap and thus barely modify the PL as compared to the bulk.

View Article and Find Full Text PDF

Background: Several research groups have explored the potential of scandium radionuclides for theragnostic applications due to their longer half-lives and equal or similar coordination chemistry between their diagnostic and therapeutic counterparts, as well as lutetium-177 and terbium-161, respectively. Unlike the gallium-68/lutetium-177 pair, which may show different in-vivo uptake patterns, the use of scandium radioisotopes promises consistent behaviour between diagnostic and therapeutic radiopeptides. An advantage of scandium's longer half-life over gallium-68 is the ability to study radiopeptide uptake over extended periods and its suitability for centralized production and distribution.

View Article and Find Full Text PDF

Methylammonium lead tribromide (MAPbBr) stands out as the most easily grown wide-band-gap metal halide perovskite. It is a promising semiconductor for room-temperature gamma-ray (γ-ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance.

View Article and Find Full Text PDF

LiMnO (LMO) cathodes present large stability when cycled in aqueous electrolytes, contrasting with their behavior in conventional organic electrolytes in lithium-ion batteries (LIBs). To elucidate the mechanisms underlying this distinctive behavior, we employ unconventional characterization techniques, including variable energy positron annihilation lifetime spectroscopy (VEPALS), tip-enhanced Raman spectroscopy (TERS), and macro-Raman spectroscopy (with tens of μm-size laser spot). These still rather unexplored techniques in the battery field provide complementary information across different length scales, revealing previously hidden features.

View Article and Find Full Text PDF

Understanding spin-lattice interactions in antiferromagnets is a critical element of the fields of antiferromagnetic spintronics and magnonics. Recently, coherent nonlinear phonon dynamics mediated by a magnon state were discovered in an antiferromagnet. Here, we suggest that a strongly coupled two-magnon-one phonon state in this prototypical system opens a novel pathway to coherently control magnon-phonon dynamics.

View Article and Find Full Text PDF