30 results match your criteria: "Institute of Environmental Engineering and Building Installations[Affiliation]"

The effects of 1-decyl-3-methylimidazolium bromide on activated sludge process and microbial composition were investigated. Ionic liquid (IL) was dosed continuously to the laboratory activated sludge system at an influent concentration from 1 to 20 mg l(-1) for about 1 month. As compared to the control test, mean values of degree of chemical oxygen demand removal and degree of biochemical oxygen demand removal were almost remaining constant at a high level, equaling 92.

View Article and Find Full Text PDF

Biodegradability of industrial textile wastewater - batch tests.

Water Sci Technol

January 2017

Faculty of Process and Environmental Engineering, Lodz University of Technology, Wolczanska 213, 90-924 Lodz, Poland E-mail:

Following new trends we applied oxygen uptake rate (OUR) tests as well as long-term tests (in two batch bioreactors systems) in order to assess the biodegradability of textile wastewater. Effluents coming from a dyeing factory were divided into two streams which differed in inorganic and organic contaminants loads. Usefulness of the stream division was proved.

View Article and Find Full Text PDF

Assessment of pollutant load emission from combined sewer overflows based on the online monitoring.

Environ Monit Assess

September 2016

Institute of Environmental Engineering and Building Installations, Technical University of Lodz, Al.Politechniki 6, 90-924, Lodz, Poland.

Cities equipped with combined sewer systems discharge during wet weather a lot of pollutants into receiving waters by combined storm overflows (CSOs). According to the Polish legislation, CSOs should be activated no more than ten times per year, but in Lodz, most of the 18 existing CSOs operate much more frequently. To assess the pollutant load emitted by one of the existing CSOs, the sensors for measuring the concentration of total suspended solids (SOLITAX sc) and dissolved chemical oxygen demand (UVAS plus) installed in the overflow chamber as well as two flowmeters placed in the outflow sewer were used.

View Article and Find Full Text PDF

Study on wastewater toxicity using ToxTrak™ method.

Environ Sci Pollut Res Int

May 2016

Institute of Environmental Engineering and Building Installations, Lodz University of Technology, Al. Politechniki 6, 90-924, Lodz, Poland.

ToxTrak™ method is an analytical tool for the measurement of toxicity of drinking water, wastewater and natural water. It is based upon the estimation of the inhibitive effect on bacterial respiration processes. The main aim of this work was to test the applicability of ToxTrak™ method in the assessment of wastewater toxicity in a full-scale WWTP in Poland.

View Article and Find Full Text PDF