5 results match your criteria: "Institute for Standardisation and Documentation in the Medical Laboratory[Affiliation]"
Clin Lab
October 2006
Reference Laboratory, Institute for Standardisation and Documentation in the Medical Laboratory, Düsseldorf, Germany.
This short article describes the results obtained in both internal and external quality assessment of point of care devices (POCD) for the monitoring of blood glucose. The results show that the use of synthetic, serum and whole blood matrices for the samples do not markedly change the inaccuracy of measurement. It is only possible to check precision of POC devices for glucose in external quality assessment (EQA) surveys for POC devices for blood glucose.
View Article and Find Full Text PDFClin Lab
December 2004
Reference Method Laboratories, Institute for Standardisation and Documentation in the Medical Laboratory, Düsseldorf, Germany.
Six thyroid analytes (free and total triiodothyronine and thyroxine, thyrotropin and thyroglobulin) have been followed up over a 10 year period in a national external quality assessment scheme (EQAS) organised by the Institute for Standardisation and Documentation in the Medical Laboratory (INSTAND). I. The following points were observed: II.
View Article and Find Full Text PDFClin Lab
October 2004
Reference Method Laboratories, Institute for Standardisation and Documentation in the Medical Laboratory, (INSTAND e. V.), Düsseldorf, Germany.
Four thyroid antibodies (antibodies to microsomes [MAb], thyroid peroxidase [anti-TPO], thyroglobulin [anti-Tg] and TSH-receptor [TRAB, THYBIA]) have been followed up over a 10-year period in a national external quality assessment scheme (EQAS) organised by the Institute for Standardisation and Documentation in the Medical Laboratory (INSTAND e.V.).
View Article and Find Full Text PDFClin Lab
March 2004
Reference Method Laboratories, Institute for Standardisation and Documentation in the Medical Laboratory (INSTAND), Düsseldorf, Germany.
This article describes a method of high analytical sensitivity, reproducibility and trueness for the determination of digoxin and digitoxin in serum or plasma at therapeutic levels using a combination of high-pressure liquid chromatography (HPLC), isotope-dilution mass spectrometry (IDMS) and caesium-adduct formation. A method for threefold deuterium substitution in the glycosides was developed, which could be performed within 24 hours without distillation giving yields > 98% of the theoretical value. Extraction from a serum or plasma matrix was performed using a liquid-phase extraction with ammonium acetate buffer/tertiary butylmethyl ether/ethyl acetate at pH 9.
View Article and Find Full Text PDFClin Lab
November 2001
Institute for Standardisation and Documentation in the Medical Laboratory (INSTAND), Reference Laboratories, Düsseldorf, Germany.
The aim of the study was to develop a method for the determination of haemoglobin in plasma suitable for use to set target values for external quality assessment schemes for this analyte using commercially available test kits and equipment. In the early phase of the method development it became clear that the use of a single method, namely HPLC, would not be possible. However, by combining HPLC and absorption spectrophotometry, both qualitative and quantitative rapid determinations of protein-bound and free haemoglobin were able to be performed on equipment present in most routine clinical chemistry laboratories.
View Article and Find Full Text PDF