117 results match your criteria: "Institute for Microstructural Sciences[Affiliation]"

The increased demand for electronic devices, combined with a desire to minimize the environmental impact, necessitates the development of new eco-friendly materials. One promising approach is the incorporation of renewable and green materials that possess the desired mechanical and electrical properties while allowing for more ecologically friendly disposal of these devices. The addition of low-weight percentages (0.

View Article and Find Full Text PDF

We experimentally demonstrate a new type of waveguide multiplexer device designed for silicon photonics, with a crosstalk level as low as -35 dB and an operational wavelength range of 300 nm. A compact device footprint of only 100 × 160 µm2 offers an excellent potential for integration with other silicon nanophotonic circuits.

View Article and Find Full Text PDF

Qubits based on the singlet (S) and the triplet (T(0), T(+)) states in double quantum dots have been demonstrated in separate experiments. It has been recently proposed theoretically that under certain conditions a quantum interference could occur from the interplay between these two qubit species. Here we report experiments and modeling that confirm these theoretical predictions and identify the conditions under which this interference occurs.

View Article and Find Full Text PDF

We report the investigation of the air photostability of benzo[1,2-b:4,5-b']dithiophene (BDT) based conjugated polymers using UV-visible spectroscopy, X-ray photoelectron spectroscopy, gel permeation chromatography, and nuclear magnetic resonance spectroscopy. Three low band gap alternating D-A copolymers consisting of 3-fluoro-2-heptylcarbonylthieno[3,4-b]thiophene and alkyl-substituted BDT, alkoxy-substituted BDT, or dithienosilole, respectively, were prepared for investigating their photovoltaic performance and photostability. After only two hours of simultaneous exposure to light and air, the main absorption peak of the polymer films containing BDT units blue-shifted and its intensity dramatically decreased.

View Article and Find Full Text PDF

An ultrawide-bandwidth, superluminescent light-emitting diode (SLED) utilizing multiple layers of dots of tuned height is reported. Due to thermal effect, the superluminescent phenomenon is observed only under pulse-mode operation. The device exhibits a 3 dB bandwidth of 190 nm with central wavelength of 1020 nm under continuous-wave (cw) conditions.

View Article and Find Full Text PDF

A new temperature performance record of 199.5 K for terahertz quantum cascade lasers is achieved by optimizing the lasing transition oscillator strength of the resonant phonon based three-well design. The optimum oscillator strength of 0.

View Article and Find Full Text PDF

The effects of specimen tilt and probe convergence angle on annular dark field (ADF) image contrast of Si(0.8)Ge(0.2) heteroepitaxial strained layers on (100) Si were investigated in a 200 kV scanning transmission electron microscope (STEM) for a TEM specimen thickness of 195 nm.

View Article and Find Full Text PDF

Due to its exquisite sensitivity and the ability to monitor and control individual cells at the level of ion channels, patch-clamping is the gold standard of electrophysiology applied to disease models and pharmaceutical screens alike. The method traditionally involves gently contacting a cell with a glass pipette filled by a physiological solution in order to isolate a patch of the membrane under its apex. An electrode inserted in the pipette captures ion-channel activity within the membrane patch or, when ruptured, for the whole cell.

View Article and Find Full Text PDF

Photoinduced band gap shift and deep levels in luminescent carbon nanotubes.

ACS Nano

February 2012

Institute for Microstructural Sciences, National Research Council Canada, Building M-50, 1200 Montreal Road, Ottawa, ON, Canada K1A OR6.

Individual air-suspended single-walled carbon nanotubes are imaged both spatially and spectrally in photoluminescence. At low excitation power, photoluminescence is bright and stable with high quantum efficiency; however, higher power initially causes a gradual red shift and then more severe changes. Blinking, the loss of quantum efficiency, and the appearance of new deep levels are all seen and can be explained by the introduction of defects.

View Article and Find Full Text PDF

We show theoretically and experimentally the existence of a new quantum-interference effect between the electron-hole interactions and the scattering by a single Mn impurity. The theoretical model, including electron-valence-hole correlations, the short- and long-range exchange interaction of a Mn ion with the heavy hole and with electron and anisotropy of the quantum dot, is compared with photoluminescence spectroscopy of CdTe dots with single magnetic ions. We show how the design of the electronic levels of a quantum dot enables the design of an exciton, control of the quantum interference, and hence engineering of light-Mn interaction.

View Article and Find Full Text PDF

A side-scanning fiber probe is a critical component for optical coherence tomography in medical imaging and diagnosis. We propose and fabricate an on-axis rotating probe that performs in situ, circumferential scanning that is shadow-free (not susceptible to shadow effects caused by the motor's wires). A miniature motor that incorporates a bored-out shaft for the optical fiber is located at the distal end of the probe, which results in a more stable and uniform circumferential scan, free from wire-shadow interference effects.

View Article and Find Full Text PDF

We demonstrate InGaAs mid-infrared quantum well infrared photodetectors (MIR PV-QWIPs) that enable cost-effective mature GaAs-based detection and imaging technologies, with exceptional material uniformity, reproducibility, and yield, over a large area, with high spectral selectivity, innate polarization sensitivity, radiation hardness, high detectivity, and high speed operation at TEC temperatures without bias.

View Article and Find Full Text PDF

All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions - including exposure to novel drug targets.

View Article and Find Full Text PDF

The advances made in the last two decades in interference technologies, optical instrumentation, catheter technology, optical detectors, speed of data acquisition and processing as well as light sources have facilitated the transformation of optical coherence tomography from an optical method used mainly in research laboratories into a valuable tool applied in various areas of medicine and health sciences. This review paper highlights the place occupied by optical coherence tomography in relation to other imaging methods that are used in medical and life science areas such as ophthalmology, cardiology, dentistry and gastrointestinal endoscopy. Together with the basic principles that lay behind the imaging method itself, this review provides a summary of the functional differences between time-domain, spectral-domain and full-field optical coherence tomography, a presentation of specific methods for processing the data acquired by these systems, an introduction to the noise sources that plague the detected signal and the progress made in optical coherence tomography catheter technology over the last decade.

View Article and Find Full Text PDF

We demonstrate, by experiment and numerical calculations, temperature-independent subwavelength grating waveguides with a periodic composite core composed of alternating regions of silicon and SU-8 polymer. The polymer has a negative thermo-optic (TO) material coefficient that cancels the large positive TO effect of the silicon. Measurements and Bloch mode calculations were carried out over a range of silicon-polymer duty ratios.

View Article and Find Full Text PDF

We report a novel (to the best of our knowledge) simultaneous 1310/1550 two-wavelength band swept laser source and dual-band common-path swept-source optical coherence tomography (SS-OCT). Synchronized dual-wavelength tuning is performed by using two laser cavities and narrowband wavelength filters with a single dual-window polygonal scanner. Measured average output powers of 60 and 27 mW have been achieved for the 1310 and 1550 nm bands, respectively, while the two wavelengths were swept simultaneously from 1227 to 1387 nm for the 1310 nm band and from 1519 to 1581 nm for the 1550 nm band at an A-scan rate of 65 kHz.

View Article and Find Full Text PDF

Optimum phase for rugate filter synthesis by Fourier transforms.

Appl Opt

March 2011

Institute for Microstructural Sciences, National Research Council of Canada, Ottawa, Ontario, Canada.

An optimum phase is developed for the synthesis of rugate reflectors by a simple Fourier transform. This phase belongs to a complex function of the desired spectral characteristics and is usually a free parameter. In general, it receives much less attention than the function magnitude, which is not known exactly.

View Article and Find Full Text PDF

Patch-clamp is an important method to monitor the electrophysiological activity of cells and the role of pharmacological compounds on specific ion channel proteins. In recent years, planar patch-clamp chips have been developed as a higher throughput approach to the established glass-pipette method. However, proper conditions to optimize the high resistance cell-to-probe seals required to measure the small currents resulting from ion channel activity are still the subject of conjecture.

View Article and Find Full Text PDF

A new alternating copolymer of dithienosilole and thienopyrrole-4,6-dione (PDTSTPD) possesses both a low optical bandgap (1.73 eV) and a deep highest occupied molecular orbital energy level (5.57 eV).

View Article and Find Full Text PDF

Brain injury can lead to irreversible tissue loss and functional deficit along with significant health care costs. Raman spectroscopy can be used as a non-invasive technique to provide detailed information on the molecular composition of diseased and damaged tissues. This technique was used to examine acute mouse brain injury, focusing on the motor cortex, a region directly involved in controlling execution of movement.

View Article and Find Full Text PDF

A comprehensive investigation of real-time temperature-induced resonance shift cancellation for silicon wire based biosensor arrays is reported for the first time. A reference resonator, protected by either a SU8 or SiO(2) cladding layer, is used to track temperature changes. The temperature dependence of resonators in aqueous solutions, pertinent to biosensing applications, is measured under steady-state conditions and the operating parameters influencing these properties are discussed.

View Article and Find Full Text PDF

We report on the experimental demonstration and analysis of a new waveguide principle using subwavelength gratings. Unlike other periodic waveguides such as line-defects in a 2D photonic crystal lattice, a subwavelength grating waveguide confines the light as a conventional index-guided structure and does not exhibit optically resonant behaviour. Subwavelength grating waveguides in silicon-on-insulator are fabricated with a single etch step and allow for flexible control of the effective refractive index of the waveguide core simply by lithographic patterning.

View Article and Find Full Text PDF

We report on the design, simulation and experimental demonstration of a new type of waveguide crossing based on subwavelength gratings in silicon waveguides. We used 3D finite-difference time-domain simulations to minimize loss, crosstalk and polarization dependence. Measurement of fabricated devices show that our waveguide crossings have a loss as low as -0.

View Article and Find Full Text PDF

We report a silicon-on-insulator ring resonator biosensor array with one output port, using wavelength division multiplexing as the addressing scheme. With the use of on-chip referencing for environmental drift cancellation, simultaneous monitoring of multiplexed molecular bindings is demonstrated, with a resolution of 0.3 pg/mm(2) (40 ag of total mass) for protein concentrations over 4 orders of magnitude down to 20 pM.

View Article and Find Full Text PDF

We present a polymer microchip capable of monitoring neuronal activity with a fidelity never before obtained on a planar patch-clamp device. Cardio-respiratory neurons Left Pedal Dorsal 1 (LPeD1) from mollusc Lymnaea were cultured on the microchip's polyimide surface for 2 to 4 hours. Cultured neurons formed high resistance seals (gigaseals) between the cell membrane and the surface surrounding apertures etched in the polyimide.

View Article and Find Full Text PDF