60 results match your criteria: "Illinois Fire Service Institute[Affiliation]"
J Occup Environ Hyg
January 2025
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), Cincinnati, Ohio.
Structural firefighters are exposed to an array of polycyclic aromatic hydrocarbons (PAHs) as a result of incomplete combustion of both synthetic and natural materials. PAHs are found in both the particulate and vapor phases in the firefighting environment and are significantly associated with acute and chronic diseases, including cancer. Using a fireground exposure simulator (FES) and standing mannequins dressed in four different firefighter personal protective equipment (PPE) conditions, each with varying levels of protective hood interface and particulate-blocking features, the efficacy of the hoods was assessed against the ingress of PAHs (specifically, naphthalene).
View Article and Find Full Text PDFJ Occup Environ Hyg
May 2024
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), Cincinnati, Ohio, USA.
Structural firefighters are exposed to a complex set of contaminants and combustion byproducts, including volatile organic compounds (VOCs). Additionally, recent studies have found structural firefighters' skin may be exposed to multiple chemical compounds via permeation or penetration of chemical byproducts through or around personal protective equipment (PPE). This mannequin-based study evaluated the effectiveness of four different PPE conditions with varying contamination control measures (incorporating PPE interface design features and particulate blocking materials) to protect against ingress of several VOCs in a smoke exposure chamber.
View Article and Find Full Text PDFJ Ind Text
November 2023
Textile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.
In 2022, the occupation of firefighting was categorized as a "Group 1" carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids.
View Article and Find Full Text PDFJ Nutr
May 2024
Department of Health and Kinesiology, University of Illinois Urbana-Champaign, Urbana, IL, United States; Division of Nutritional Sciences, University of Illinois Urbana-Champaign, Urbana, IL, United States. Electronic address:
Background: Digestibility is a primary factor in determining the quality of dietary protein. Microbial protease supplementation may be a strategy for improving protein digestion and subsequent postprandial plasma amino acid availability.
Objectives: To assess the effect of co-ingesting a microbial protease mixture with pea protein on postprandial plasma amino acid concentrations.
J Spinal Cord Med
September 2024
Illinois Fire Service Institute, University of Illinois, Urbana-Champaign, Illinois, USA.
Context: During the evacuation of a residence during a fire event, individuals must often climb over objects or navigate stairs, which may be challenging or impossible for an individual who uses a wheelchair or scooter for mobility. Consequently, fire preparedness is critical to enhancing this population's safety and well-being.
Objective: This study examines best practices associated with fire preparedness among individuals who use a wheelchair or scooter to inform and facilitate fire preparedness education.
Int J Environ Res Public Health
June 2023
Fire Safety Research Institute, UL Research Institutes, Columbia, MD 21045, USA.
Firefighters are at an increased risk of cancer due to their occupational exposure to combustion byproducts, especially when those compounds penetrate the firefighter personal protective equipment (PPE) ensemble. This has led to questions about the impact of base layers (i.e.
View Article and Find Full Text PDFAppl Spectrosc
April 2023
Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA.
A versatile portable tunable diode laser based measurement system for measuring elevated concentrations of hydrogen cyanide (HCN) in a time-resolved manner is developed for application in the fire environment. The direct absorption tunable diode laser spectroscopy (DA-TDLAS) technique is employed using the R11 absorption line centered at 3345.3 cm (2989.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
February 2023
Sports Medicine, Mayo Clinic Health System, La Crosse, WI 54650, USA.
Unlabelled: Firefighters often complete air management courses (AMC) to assess the ability to tolerate personal protective equipment, appropriately manage the breathing system and assess occupational performance. Little information is known relative to the physiological demands of AMCs, nor how to assess work efficiency in order to characterize occupational performance and evaluate progress.
Purpose: To assess the physiological demands of an AMC and examine differences across BMI categories.
Int J Environ Res Public Health
January 2023
Fire Safety Research Institute, UL Research Institutes, Columbia, MD 21045, USA.
Chronic health risks associated with firefighting continue to be documented and studied, however, the complexity of occupational exposures and the relationship between occupational exposure and contaminated personal protective equipment (PPE) remains unknown. Recent work has revealed that common PPE cleaning practices, which are becoming increasingly more common in the fire service, are not effective in removing certain contaminants, such as polycyclic aromatic hydrocarbons (PAHs), from PPE. To better understand the relationship between contaminated firefighter PPE and potential exposure to PAHs, and to gain further understanding of the efficacy of cleaning practices, we used a standardized fire exposure simulator that created repeatable conditions and measured PPE surface contamination levels via wipe sampling and filters attached to firefighter gear worn by standing mannequins.
View Article and Find Full Text PDFInt J Hyg Environ Health
March 2023
Department of Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural & Life Sciences Building, Corvallis, OR, 97331, USA. Electronic address:
A plethora of chemicals are released into the air during combustion events, including a class of compounds called polycyclic aromatic hydrocarbons (PAHs). PAHs have been implicated in increased risk of cancer and cardiovascular disease, both of which are disease endpoints of concern in structural firefighters. Current commercially available personal protective equipment (PPE) typically worn by structural firefighters during fire responses have gaps in interfaces between the ensemble elements (e.
View Article and Find Full Text PDFJ Occup Environ Hyg
September 2022
Illinois Fire Service Institute, Champaign, Illinois.
The international fire service community is actively engaged in a wide range of activities focused on development, testing, and implementation of effective approaches to reduce exposure to contaminants and the related cancer risk. However, these activities are often viewed independent of each other and in the absence of the larger overall effort of occupational health risk mitigation. This narrative review synthesizes the current research on fire service contamination control in the context of the National Institute for Occupational Safety and Health (NIOSH) Hierarchy of Controls, a framework that supports decision making around implementing feasible and effective control solutions in occupational settings.
View Article and Find Full Text PDFVet Surg
October 2022
Department of Clinical Veterinary Medicine, College of Veterinary Medicine, University of Illinois, Urbana-Champaign, Illinois, USA.
Objective: To assess the effect of repeated freezing and thawing on the suture pull-out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure.
Study Design: Ex vivo experimental study.
Sample Population: Ten grossly normal equine cadaveric larynges.
Nat Commun
June 2022
Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
In Fall 2020, universities saw extensive transmission of SARS-CoV-2 among their populations, threatening health of the university and surrounding communities, and viability of in-person instruction. Here we report a case study at the University of Illinois at Urbana-Champaign, where a multimodal "SHIELD: Target, Test, and Tell" program, with other non-pharmaceutical interventions, was employed to keep classrooms and laboratories open. The program included epidemiological modeling and surveillance, fast/frequent testing using a novel low-cost and scalable saliva-based RT-qPCR assay for SARS-CoV-2 that bypasses RNA extraction, called covidSHIELD, and digital tools for communication and compliance.
View Article and Find Full Text PDFInt J Hyg Environ Health
May 2022
Fire Safety Research Institute, Underwriters Laboratories Inc, Columbia, MD, USA; Illinois Fire Service Institute, University of Illinois at Urbana-Champaign, IL, USA.
Introduction: Firefighters are exposed to volatile organic compounds (VOCs) during structural fire responses and training fires, several of which (e.g., benzene, acrolein, styrene) are known or probable carcinogens.
View Article and Find Full Text PDFInt J Environ Res Public Health
February 2022
Illinois Fire Service Institute, University of Illinois Urbana-Champaign, Champaign, IL 61820, USA.
While the fire service has long been a male-dominated occupation, women's participation in this strenuous, high risk, high performance activity has increased in recent years. Firefighting induces significant cardiovascular strain, including hemostatic disruption; however, the effect of sex on hemostatic responses has not been investigated despite evidence that there are sex-related differences in hemostatic variables at rest and following exercise. Thus, we investigated hemostatic responses in age- and BMI-matched male and female firefighters who performed 3-4 evolutions of firefighting drills over a 3 h period.
View Article and Find Full Text PDFInt J Environ Res Public Health
December 2021
Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA.
Background: Firefighting is a strenuous profession requiring adequate levels of fitness for effective job performance. Providing firefighters with a safe and effective fitness program is essential for optimal performance. The purpose of this project was to examine changes in various parameters of physical fitness and firefighter ability following a 7-week high intensity functional training (HIFT) program.
View Article and Find Full Text PDFInt J Hyg Environ Health
March 2022
Fire Safety Research Institute, Underwriters Laboratories, Columbia, MD, USA.
The fire service has become more aware of the potential for adverse health outcomes due to occupational exposure to hazardous combustion byproducts. Because of these concerns, personal protective equipment (PPE) manufacturers have developed new protection concepts like particulate-blocking hoods to reduce firefighters' exposures. Additionally, fire departments have implemented exposure reduction interventions like routine laundering of PPE after fire responses.
View Article and Find Full Text PDFEur J Appl Physiol
March 2022
Integrative Physiology Laboratory, University of Illinois at Chicago, Chicago, IL, USA.
Introduction: Cardiovascular events are a leading cause of firefighter duty-related death, with the greatest risk occurring during or shortly after fire suppression activity. Increased cardiovascular risk potentially manifests from detrimental changes in ventricular function, vascular load, and their interaction, described as ventricular-vascular coupling.
Purpose: To determine the effect of live-fire training on ventricular-vascular coupling.
Int J Environ Res Public Health
November 2021
Department of Kinesiology and Community Health, College of Applied Health Sciences, University of Illinois Urbana-Champaign, Champaign, IL 61820, USA.
Regular exercise in firefighters may be effective in preventing or attenuating ill health (e.g., hypertension, diabetes, and obesity), as well as improving their firefighting ability.
View Article and Find Full Text PDFVet Surg
October 2021
Department of Clinical Veterinary Medicine, College of Veterinary Medicine, University of Illinois, Urbana-Champaign, Illinois, USA.
Objective: To evaluate the airway mechanics of modified toggle LP constructs in an airflow chamber model and compare these to the airway mechanics of standard LP constructs.
Study Design: Ex-vivo experimental study.
Sample Population: Fifty-one equine cadaveric larynges.
J Occup Environ Med
July 2021
Department of Health and Human Physiological Sciences, Skidmore College, Saratoga Springs, New York.
BMC Public Health
June 2021
Department of Health and Human Physiological Sciences, Skidmore College, 815 North Broadway, Saratoga Springs, NY, 12866, USA.
Background: Research consistently finds that, on average, firefighters gain weight over time and some data indicate that younger firefighters are more likely to gain weight than older firefighters. The purpose of this study was to estimate the 5-year weight change among younger and older US firefighters.
Methods: Data from two occupational medical exams separated by 5 years (2009-2016) were examined from a cohort of US career firefighters in Virginia (males, n = 589; females, n = 67).
Int J Hyg Environ Health
July 2021
Division of Laboratory Services, National Center for Environmental Health, CDC, Atlanta, GA, USA.
Firefighters may encounter items containing flame retardants (FRs), including organophosphate flame retardants (OPFRs) and polybrominated diphenyl ethers (PBDEs), during structure fires. This study utilized biological monitoring to characterize FR exposures in 36 firefighters assigned to interior, exterior, and overhaul job assignments, before and after responding to controlled residential fire scenarios. Firefighters provided four urine samples (pre-fire and 3-h, 6-h, and 12-h post-fire) and two serum samples (pre-fire and approximately 23-h post-fire).
View Article and Find Full Text PDFErgonomics
June 2021
Illinois Fire Service Institute, University of Illinois Urbana-Champaign, Urbana, IL, USA.
Firefighter hoods must provide protection from elevated temperatures and products of combustion (e.g. particulate) while simultaneously being wearable (comfortable and not interfering with firefighting activities).
View Article and Find Full Text PDFJ Occup Environ Hyg
April 2021
Illinois Fire Service Institute, University of Illinois, Urbana-Champaign, Illinois, USA.
As the Fire Service becomes more aware of the potential health effects from occupational exposure to hazardous contaminants, personal protective equipment (PPE) manufacturers, and fire departments have responded by developing and implementing improved means of firefighter protection, including more frequent laundering of PPE after exposures. While laboratory testing of new PPE designs and the effect of laundering on PPE fabric provides a useful way to evaluate these approaches, laboratory scale testing does not necessarily translate to full garment protection. Utilizing a fireground smoke exposure simulator, along with air and/or filter-substrate sampling for polycyclic aromatic hydrocarbons (PAHs) and benzene, this pilot study tested the chemical-protective capabilities of firefighting PPE of different designs (knit hood .
View Article and Find Full Text PDF