64 results match your criteria: "Herminio Ometto University Center[Affiliation]"

This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate Luminous White Instant + violet LED bleaching; C: Brushing with Colgate Total 12; LB: Brushing with Colgate Luminous White Brilliant; LI: Brushing with Colgate Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations.

View Article and Find Full Text PDF

Objective: To evaluate the mechanical properties of different CAD/CAM ceramic systems and the post-fatigue fracture and stress distribution when used as cemented crowns.

Materials And Methods: Sixty (60) CAD/CAM monolithic crowns were milled using three different ceramic materials (FD - Feldspathic [Vita Mark II]), LE - Leucite-based ceramic [IPS Empress CAD] and LD - Lithium Disilicate [IPS e.max CAD]) and adhesively cemented on resin composite dyes.

View Article and Find Full Text PDF

To evaluate the ethanol wet-bonding protocol with a universal adhesive in etch-andrinse and self-etch modes on microleakage and microtensile bond strength (μTBS) of resin composite to different dentin depth. Molars were distributed into groups according to protocol and dentin depth: universal adhesive (C - control), ethanol + universal adhesive (E), and phosphoric acid etch + ethanol + universal adhesive (PA+E). All protocols were applied to dentin at superficial, middle and deep depths.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate efficacy of violet LED light for the bleaching treatment of primary incisors darkened by trauma.

Methods: Twenty deciduous incisors with color change were selected, divided into two groups: control - no bleaching protocol was applied, and VL- treated with violet LED. The change color analysis was taken in each tooth, by spectrophotometer.

View Article and Find Full Text PDF

Thisstudy aimed to evaluate the effect of the electric current direction application on the resin composite-dentin bond strength using three adhesive systems. Human molar teeth were distributed according to the adhesive system (two-step self-etch - Clearfil SE Bond, Kuraray [CSE]; one-step self-etch - Single Bond Universal, 3M ESPE [SBU]; and two-step etch-and-rinse - Adper Single Bond 2, 3M ESPE [SB2]), electric current direction (without electric current - control, direct and reverse electric currents - 35µA), and storage time (24h - immediate and 6 months). Resin composite blocks (Filtek Z350XT, 3M ESPE) were bonded to dentin.

View Article and Find Full Text PDF

Nutritional restriction during developmental periods impairs organ physiology. Female rats were subjected to protein restriction during pregnancy and lactation to analyze dental and maxillary development. Four exposure groups were considered: normal-protein diet during pregnancy and lactation (NP, 17% casein), low-protein diet during lactation (LP-L, 6% casein), low-protein diet during pregnancy and lactation (LP), and low-protein diet during pregnancy (LP-G).

View Article and Find Full Text PDF

Objectives: The objective of this systematic review was to compare the longevity of direct amalgam and composite resin restorations, in posterior teeth, through clinical, prospective or retrospective studies, with at least 5 years of follow-up.

Materials And Methods: Studies published in the last 15 years (from 2006 to 2021) were collected using the PubMed and Medline databases.

Results: The search strategy associated with the established inclusion and exclusion criteria resulted in a total of 17 articles.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the microhardness and quantify the presence of minerals (Calcium and Phosphorous) of tooth enamel submitted to bleaching with violet LED light, either associated with 35% hydrogen peroxide gel, or not.

Methods: Bovine incisors were selected and divided into 4 Groups according to the bleaching technique used: C- Without bleaching (Control); VL- violet LED; HP- 35% Hydrogen Peroxide; HP+VL- 35% Hydrogen Peroxide + violet LED. The response variables were surface microhardness (n = 12), Energy Dispersive Spectroscopy (EDS) (n = 6) and scanning electron microscopy (SEM) (n = 3).

View Article and Find Full Text PDF

Rheumatoid arthritis (RA) is a chronic autoimmune disease characterized by inflammation and involvement of the synovial membrane, causing joint damage and deformities. No effective drug treatment is available, and physical exercise has been utilized to alleviate the inflammatory processes. This study aimed to investigate the effects of different exercise training protocols on Zymosan-induced RA inflammatory markers in the right knee of Wistar rats.

View Article and Find Full Text PDF

Experimental resin-based dual-cured calcium aluminate and calcium titanate materials for vital pulp therapy.

Braz Oral Res

March 2022

Universidade Federal de Pelotas - UFPes, Materials Engineering Graduate Program, Advanced Crystal Growth and Photonics, Pelotas, RS, Brazil.

This paper evaluates the physicochemical and biological properties of experimental resin-based dual-cured calcium aluminate (CA) and calcium titanate (CTi) materials for vital pulp therapy (VPT). The experimental dual-cured materials were obtained as two pastes: a) Bis-EMA 10, PEG 400, DHEPT, EDAB, camphorquinone, and butylated hydroxytoluene; and b) fluoride ytterbium, Bis-EMA 10, Bis-EMA 30, benzoyl peroxide, and butylated hydroxytoluene. The materials were divided into six groups based on the added calcium component: MTA (MTA®, Angelus); CLQ (Clinker-Fillapex®, Angelus); CA (calcined at ,1200°C in pastes a and b); CA800 (calcined at 800°C in paste a); CA1200 (calcined at 1,200°C in paste a); and CTi (paste a).

View Article and Find Full Text PDF

This study evaluated stresses generated at maxillary central incisor (21) root restored with lithium disilicate crown (LDC), and glass fiber (GFP) or polyetheretherketone (PEEK) post. 3D models created by computed tomographic image (i-CAT Cone Beam 3D Dental Imaging System) reproduced maxillary central incisor. Each model had prosthetic LDCs (2.

View Article and Find Full Text PDF

Objectives: The purpose of this systematic review was to collect and discuss the technique of adhesive systems application on dentin substrate under electric current.

Materials And Methods: The first search strategy was based on data available at PubMed, LILACS, Scielo, Scopus, and Cochrane Library, using a combination of descriptors such as "dentin bond agents OR adhesive system AND electric current OR electrobond" or "dentin bonding agents OR dentin bonding agent application OR adhesive system AND electric current OR electrobond", with no limit regarding the publication year. The second search strategy was based on the articles' references found previously.

View Article and Find Full Text PDF

Objectives: The aim of this study was to evaluate using finite element analysis (FEA), the stress distribution in prostheses (lithium disilicate crowns) on monotype zirconia implants with and without cantilever in the anterior region of the maxilla.

Materials And Methods: From a virtual reconstruction of bone model of the toothed maxilla from a computed tomography, three models (groups) were created: Zr (11-21)-implants placed in the area of 11 and 21 with cantilever; Zr (12-22)-implants placed in the area of 12 and 22 without cantilever; and Zr (11-22)-implants intercalated placed in the area of 11 and 22. In all models, monotype zirconia implant (4.

View Article and Find Full Text PDF

Denervation leads to severe atrophy of neuromuscular junction (NMJ) structure including decrease of the expression of fundamental proteins. Up to now, conventional suture has been the gold standard method used to correct this injury. Fibrin sealant is one of the alternatives proposed to optimize this method.

View Article and Find Full Text PDF

This study aimed to evaluate in vitro and in vivo polymeric membranes obtained by a rotary jet-spinning process for the repair of critical bone defects in the calvaria of Wistar rats, for future use in tissue engineering. Experimental sample collections were performed on the 30, 60 and 90th postoperative days, and the analyses performed were histomorphometric, immunohistochemistry, and western blotting. Reducing inflammatory infiltrate in all groups and experimental periods, angiogenesis on the 30th day did not show any difference between the groups, on the 60th day, 5% polycaprolactone/beta-tricalcium phosphate(PCL/β-TCP) was high compared to control (C), and on the 90th day, the same group reduced when compared to C and 10% PCL/β-TCP.

View Article and Find Full Text PDF

Objectives: To evaluate the effect of electric current application on the resin composite-tooth bond strength and hybrid layer of three adhesive systems light-cured by two light-curing units (LCUs).

Materials And Methods: Human molar teeth were distributed into 12 groups (n=6). Three adhesive systems were used: two-step etch-and-rinse (SB2; Adper Single Bond 2, 3M ESPE); two-step self-etch (CSE; Clearfil SE Bond, Kuraray); and one-step self-etch (SBU; Single Bond Universal, 3M ESPE) applied with (50μA) and without (control; conventional application) electric current, and light-cured with different LCUs.

View Article and Find Full Text PDF

Objectives:  The aim of this study was to evaluate the Knoop hardness (KH), cross-link density (CLD), water sorption (WS), water solubility (WSB), and volumetric shrinkage (VS) of experimental resins blends containing a monomethacrylate with low-polymerization shrinkage.

Materials And Methods:  A blend of bisphenol glycidyl methacrylate (BisGMA) as base monomer was formulated with (Bis-GMA)/triethyleneglycol dimethacrylate (TEGDMA), Bis-GMA/isobornyl methacrylate (IBOMA), or Bis-GMA/TEGDMA/IBOMA in different concentrations (40, 50, or 60 wt%). The camphorquinone (CQ)/2-(dimethylamino) ethyl methacrylate (DMAEMA) was used as the photoinitiator system.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the in vitro color of dental enamel bleached with the violet LED, associated with or without low-concentration of peroxide; analyzed in two time intervals: 24 h later and 6 months after the treatment.

Methods: Ninety fragments of bovine teeth (6 × 6 mm and 3 mm thick) were randomly divided into 6 groups according to bleaching treatment: NB - no bleaching, VL - Violet LED, HP- 7.5 % hydrogen peroxide, HP + VL - 7.

View Article and Find Full Text PDF

Tailoring the surface properties of materials for biomedical applications is important to avoid clinical complications. Forming thin layers of amphiphilic molecules with apolar regions that facilitate attractive intermolecular interactions, can be a suitable and versatile approach to achieve hydrophobic surface modification and provide functional antibacterial properties. Aiming to correlate layer structure and properties starting from film formation, octadecylphosphonic acid (ODPA) and dimethyloctadecyl (3-trimethoxysilylpropyl) ammonium chloride (DMOAP) layers were adsorbed onto smooth titania surfaces.

View Article and Find Full Text PDF

Purpose: The present in silico study evaluated the behavior of titanium dental implants associated with abutments in zirconia and monotype zirconia implant using finite element analysis (FEA).

Methods: A partial image of the anterior region of the maxilla was obtained by computed tomography. Three models of finite element were made using 3D modeling software (SolidWorks): Ti-Ti (control): implant morse cone (3.

View Article and Find Full Text PDF

Background: Actinic cheilitis is induced by chronic exposure to ultraviolet radiation and shows solar elastosis, a feature that has been associated with mast cell infiltrates. This study aimed to investigate the area of solar elastosis, collagen loss, and mast cell infiltrates in a series of actinic cheilitis.

Methods: We evaluated the epithelial dysplasia in 52 cases of actinic cheilitis and the solar elastosis with Weigert's resorcin-fuchsin.

View Article and Find Full Text PDF

Objective: To investigate the effects of acupuncture and moxibustion on the repair of excisional skin injuries on the back of adult female Wistar rats.

Methods: 90 animals were divided into three groups: C, control; A, acupuncture treatment (needled at traditional acupuncture points BL13, BL17 and ST36); M, moxibustion treatment (overlying same traditional acupuncture points). They were euthanased on days 7, 14 and 21 after injury for removal and preparation of tissue for analysis.

View Article and Find Full Text PDF

Aim: The aim of this study was to evaluate the influence of different concentrations of two photoinitiators and one co-initiator on the flexural strength (FS) and elastic modulus (E) of experimental resin cements.

Materials And Methods: A mixture containing BisGMA, TEGDMA, and barium-aluminum-silicate (BaAlSi) and silanized colloidal silica (SiO) filler particles was prepared with two photoinitiators, viz. camphorquinone (CQ) and bisacylphosphine oxide (BAPO).

View Article and Find Full Text PDF

ARHGAP21 is a Rho-GAP that controls GTPases activity in several tissues, but its role on liver lipid metabolism is unknown. Thus, to achieve the Rho-GAP role in the liver, control and ARHGAP21-haplodeficient mice were fed chow (Ctl and Het) or high-fat diet (Ctl-HFD and Het-HFD) for 12 weeks, and pyruvate and insulin tolerance tests, insulin signaling, liver glycogen and triglycerides content, gene and protein expression, and very-low-density lipoprotein secretion were measured. Het mice displayed reduced body weight and plasma triglycerides levels, and increased liver insulin signaling.

View Article and Find Full Text PDF

Objectives: Evaluate the bone remodeling during orthodontic movement with corticotomy when submitted to low-intensity electrical stimulation application (microcurrent-MC) and low-level laser therapy (LLLT).

Material And Methods: One hundred and fifty Wistar rats were divided into the following 5 groups: (C) submitted to tooth movement; (Cort) tooth movement/corticotomy; (Cort-L) tooth movement/corticotomy/laser AsGaAl 808 nm (4.96J/50s); (Cort-Mc) tooth movement/corticotomy/microcurrent (10 μA/5 min); (Cort-L-Mc) tooth movement/corticotomy and laser/microcurrent alternated.

View Article and Find Full Text PDF