1 results match your criteria: "From the Eye Institute of West Florida (Hummel[Affiliation]"

Cyclorotation during femtosecond laser-assisted cataract surgery measured using iris registration.

J Cataract Refract Surg

July 2017

From the Eye Institute of West Florida (Hummel, Diakonis, Desai, Arana, Weinstock), Largo, Florida, and the Ophthalmic Consultants of Long Island (Hummel), Long Island, New York, USA.

Article Synopsis
  • The study assessed cyclorotation (rotation of the eye) in patients undergoing femtosecond laser-assisted cataract surgery using iris registration techniques.
  • A total of 241 patients were evaluated, revealing a mean cyclorotation of 5.81 degrees, with incyclorotation occurring more frequently than excyclorotation.
  • The findings indicate that significant eye rotation can impact astigmatism correction during surgery, highlighting the importance of iris registration for accurate corrective measures.
View Article and Find Full Text PDF