269 results match your criteria: "F-69373; Centre de Neurosciences Cognitives de Lyon[Affiliation]"

Design, synthesis, and structure-activity relationship studies of 6-benzo[]indeno[1,2-]thiophen-6-one derivatives as DYRK1A/CLK1/CLK4/haspin inhibitors.

RSC Med Chem

October 2024

Universite Claude Bernard Lyon 1, CNRS UMR 5246, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires (ICBMS), COSSBA Team, Faculté de Pharmacie, ISPB 8, avenue Rockefeller F-69373 Lyon Cedex 08 France

A series of sulfur-containing tetracycles was designed and evaluated for their ability to inhibit protein kinase DYRK1A, a target known to have several potential therapeutic applications including cancers, Down syndrome or Alzheimer's disease. Our medicinal chemistry strategy relied on the design of new compounds using ring contraction/isosteric replacement and constrained analogy of known DYRK1A inhibitors, thus resulting in their DYRK1A inhibitory activity enhancement. Whereas a good inhibitory effect of targeted DYRK1A protein was observed for 5-hydroxy compounds 4i-k (IC = 35-116 nM) and the 5-methoxy derivative 4e (IC = 52 nM), a fairly good selectivity towards its known DYRK1B off-target was observed for 4k.

View Article and Find Full Text PDF
Article Synopsis
  • A study called FABRYDIAL aimed to determine how common Fabry disease (FD) is among dialysis patients aged 18 to 74 in France, involving 124 dialysis centers and excluding cases of nephropathy unrelated to FD.
  • Out of 6,032 targeted patients, 3,088 (73.6%) were included, with biochemical and genetic tests conducted on samples to identify potential cases of FD.
  • The findings revealed a low prevalence of FD: 0.058% in males, 0% in females, and 0.035% overall, suggesting that while rare, signs of FD should be investigated in patients with unexplained kidney issues due to its serious implications if diagnosed early.
View Article and Find Full Text PDF

PD-1/PD-L1 blockade has so far shown limited survival benefit for high-grade ovarian carcinomas. By using paired samples from the NeoPembrOv randomized phase II trial (NCT03275506), for which primary outcomes are published, and by combining RNA-seq and multiplexed immunofluorescence staining, we explore the impact of NeoAdjuvant ChemoTherapy (NACT) ± Pembrolizumab (P) on the tumor environment, and identify parameters that correlated with response to immunotherapy as a pre-planned exploratory analysis. Indeed, i) combination therapy results in a significant increase in intraepithelial CD8PD-1 T cells, ii) combining endothelial and monocyte gene signatures with the CD8B/FOXP3 expression ratio is predictive of response to NACT + P with an area under the curve of 0.

View Article and Find Full Text PDF

Background: Locally advanced non-small cell lung cancer (LA-NSCLC) reported poor 5-year survival rates with frequent local or regional recurrences. Personalized RT may contribute to improve control and clinical outcome. We investigated efficacy and tolerance of "Mid-position" (Mid-P) strategy versus the conventional Internal Target Volume (ITV) strategy in LA-NSCLC patients treated by definitive conformal radiotherapy.

View Article and Find Full Text PDF

Evolution of work conditions for employees driving for work in France based on data from the 2003, 2010 and 2017 SUMER surveys (Surveillance Médicale des expositions aux risques Professionnels).

J Safety Res

June 2024

Univ Lyon, University Lyon 1, Transport Work and Environmental Epidemiology Research and Surveillance Unit - UMRESTTE (UMR T9405), F-69373 Lyon, France; Regional Centre for Occupational and Environmental Pathologies, Hôpital Lyon Sud, 69495 Pierre Bénite Cedex, France. Electronic address:

Introduction: The occupational road-accident risk on public roads and the work conditions for professional driving is still an important issue in occupational health despite lower road-accident rates. This study presents the evolution over time of the work-related constraints for these employees based on the Sumer surveys carried out in 2003, 2010 and 2017.

Method: Data from the 2010 and 2017 surveys were restricted to match the scope of the 2003 survey in order to enable prevalence data to be compared in equivalent populations.

View Article and Find Full Text PDF

The design of prompt-gamma detectors necessitates numerous Monte Carlo simulations to precisely develop and optimize the detection stages in proton therapy. Alongside the advancement of MC simulations, various variance reduction methods have been explored to speed-up calculations. Among these techniques, track-length estimators are interesting scoring methods for achieving both speed and accuracy in Monte Carlo simulations of rare events.

View Article and Find Full Text PDF
Article Synopsis
  • Spectral computed tomography (CT) is an advanced version of conventional CT that enhances imaging capabilities through dual-energy and photon-counting methods.
  • These methods offer benefits like improved image quality, better material analysis, and enhanced feature measurement compared to traditional CT.
  • Despite these advancements, spectral CT faces challenges like data and image artifacts, leading to a growing use of machine learning techniques to resolve these issues in clinical settings.
View Article and Find Full Text PDF

The syntheses of novel 2,4-bis[(substituted-aminomethyl)phenyl]phenylquinazolines and 2,4-bis[(substituted-aminomethyl)phenyl]phenylquinolines are reported here in six steps starting from various halogeno-quinazoline-2,4-(1,3)-diones or substituted anilines. The antiproliferative activities of the products were determined in vitro against a panel of breast (MCF-7 and MDA-MB-231), human adherent cervical (HeLa and SiHa), and ovarian (A2780) cell lines. Disubstituted 6- and 7-phenyl-bis(3-dimethylaminopropyl)aminomethylphenyl-quinazolines , , and displayed the most interesting antiproliferative activities against six human cancer cell lines.

View Article and Find Full Text PDF

Background: Cone beam computed tomography (CBCT) is widely used in many medical fields. However, conventional CBCT circular scans suffer from cone beam (CB) artifacts that limit the quality and reliability of the reconstructed images due to incomplete data.

Purpose: Saddle trajectories in theory might be able to improve the CBCT image quality by providing a larger region with complete data.

View Article and Find Full Text PDF

Pancreatic ductal adenocarcinoma (PDAC) is associated with a vast stromal reaction that arises mainly from cancer-associated fibroblasts (CAFs) and promotes both immune escape and tumor growth. Here, we used a mouse model with deletion of the activin A receptor ALK4 in the context of the mutation, which strongly drives collagen deposition that leads to tissue stiffness. By ligand-receptor analysis of single-cell RNA-sequencing data, we identified that, in stiff conditions, neoplastic ductal cells instructed CAFs through sustained platelet-derived growth factor (PDGF) signaling.

View Article and Find Full Text PDF

Image quality improvement of a one-step spectral CT reconstruction on a prototype photon-counting scanner.

Phys Med Biol

December 2023

Univ. Lyon, INSA-Lyon, UCBLyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR5220, U1294, F-69373 Lyon, France.

. X-ray spectral computed tomography (CT) allows for material decomposition (MD). This study compared a one-step material decomposition MD algorithm with a two-step reconstruction MD algorithm using acquisitions of a prototype CT scanner with a photon-counting detector (PCD).

View Article and Find Full Text PDF

AS1411 aptamer tagged PEGylated liposomes as a smart nanocarrier for tumor-specific delivery of Withaferin A for mitigating pulmonary metastasis.

Biomater Adv

November 2023

Laboratory of Immunopharmacology and Experimental Therapeutics, Division of Cancer Research, Regional Cancer Centre, Medical College post, Thiruvananthapuram 695011, Kerala, India (Recognized Research Centre, University of Kerala). Electronic address:

Metastasis is the most challenging health problem contributing to about 90 % of cancer-related deaths worldwide. Metastatic tumors are highly aggressive and resistant to the most available therapeutic options. Hence, innovative therapeutic approaches are required to target metastatic tumors selectively.

View Article and Find Full Text PDF

Factors associated with short- and long-term outcomes in lung cancer patients requiring unplanned invasive mechanical ventilation.

Med Intensiva (Engl Ed)

January 2024

Hospices Civils de Lyon, Hôpital Edouard Herriot, Service de Médecine Intensive-Réanimation, F-69437, Lyon, France; Université de Lyon, Université Claude Bernard Lyon 1, Faculté de Médecine Lyon-Est, F-69373, Lyon, France. Electronic address:

Article Synopsis
  • Unplanned invasive mechanical ventilation (IMV) in lung cancer patients is linked to high mortality rates, with a study aiming to identify factors affecting weaning, ICU survival, and 1-year survival among these patients.
  • The study analyzed data from 136 lung cancer patients over ten years, finding that 38% were successfully weaned from IMV, 38% were discharged from the ICU, and only 16% survived one year later.
  • Key factors influencing weaning and ICU survival included oxygen levels upon admission and the reason for intubation, while long-term survival was primarily affected by the presence of metastasis at the time of admission.
View Article and Find Full Text PDF

Image reconstruction from truncated fan-beam projections along a circular trajectory using the virtual fan-beam method.

Phys Med Biol

December 2023

Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69373, LYON, France.

In this paper, we investigate how the virtual fan-beam (VFB) method can be used to perform mathematically correct 2D reconstruction in a region-of-interest (ROI), using truncated fan-beam projections acquired on a circular scan, for truncation that only occurs on one side of the object.We start by choosing a virtual fan-beam trajectory and specifying how to obtain the corresponding virtual projections. Then, three VFB formulas are obtained by applying known super-short-scan (SSS) formulas to this virtual trajectory.

View Article and Find Full Text PDF

Equal parallel and cone-beam projections: a curious property of D-symmetric object functions.

Phys Med Biol

September 2023

Univ. Lyon, INSA-Lyon, UCB Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR5220, U1294, F-69373 Lyon, France.

In tomographic image reconstruction, the object density function is the unknown quantity whose projections are measured by the scanner. In the three-dimensional case, we define the D-reflection of such a density function as the object obtained by a particular weighted reflection about the plane=, and a D-symmetric function as one whose D-reflection is equal to itself. D-symmetric object functions have the curious property that their parallel projection onto the detector plane=is equal to their cone-beam projection onto the same detector with x-ray source location at the origin.

View Article and Find Full Text PDF

Spectral computed tomography (CT) has recently emerged as an advanced version of medical CT and significantly improves conventional (single-energy) CT. Spectral CT has two main forms: dual-energy computed tomography (DECT) and photon-counting computed tomography (PCCT), which offer image improvement, material decomposition, and feature quantification relative to conventional CT. However, the inherent challenges of spectral CT, evidenced by data and image artifacts, remain a bottleneck for clinical applications.

View Article and Find Full Text PDF

The INFN proton computed tomography system for relative stopping power measurements: calibration and verification.

Phys Med Biol

July 2023

Istituto Nazionale di Fisica Nucleare sezione di Firenze, Via G. Sansone 1, Sesto Fiorentino (Fi), Italy.

. This paper describes the procedure to calibrate the three-dimensional (3D) proton stopping power relative to water (SPR) maps measured by the proton computed tomography (pCT) apparatus of the Istituto Nazionale di Fisica Nucleare (INFN, Italy). Measurements performed on water phantoms are used to validate the method.

View Article and Find Full Text PDF

A new standardized tool for quantification of closed-loop communication in trauma care: CAST Grid reliability study.

Injury

September 2023

Université Claude Bernard Lyon 1, Centre Lyonnais d'Enseignement par la Simulation en Santé (CLESS), Lyon, France; Service d'Anesthésie-Réanimation, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France; Service de Médecine Intensive Adulte, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Suisse.

Article Synopsis
  • The CAST Grid was created to assess closed-loop communication (CLC) in trauma settings.
  • Two independent reviewers used the CAST Grid along with other validated tools to evaluate trauma care simulation videos from a French Level 1 trauma center.
  • The study found that while the agreement on CLC frequency was moderate to good, the percentage of CLC showed poor agreement, indicating CLC frequency could be useful for analyzing team interactions in trauma care.
View Article and Find Full Text PDF

. The goal of this study was to assess the imaging performances of the pCT system developed in the framework of INFN-funded (Italian National Institute of Nuclear Physics) research projects. The spatial resolution, noise power spectrum (NPS) and RSP accuracy has been investigated, as a preliminary step to implement a new cross-calibration method for x-ray CT (xCT).

View Article and Find Full Text PDF

Reliability and reproducibility of the DICART device to assess capillary refill time: a bench and in-silico study.

J Clin Monit Comput

October 2023

Service d'Anesthésie-Réanimation, Hospices Civils de Lyon, Hôpital Louis Pradel, Lyon, F-69500, France.

Capillary refill time (CRT) is an important indicator of peripheral perfusion with a strong prognostic value, but it is sensitive to environmental factors and numerous measurement methods are reported in the litterature. DiCARTECH has developed a device that assesses CRT. We sought to investigate the robustness of the device and the reproducibility of the algorithm in a bench and in-silico study.

View Article and Find Full Text PDF

Predictive stability, novel HPLC-MS analysis and semi-automatic compounding process for the emergency implementation of a production line of pancuronium in injectable solution.

Eur J Pharm Sci

August 2023

Service Pharmaceutique, Plateforme FRIPHARM, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Place d'Arsonval, F-69437 Lyon Cedex 03, France; Laboratoire de Recherche et Développement de Pharmacie Galénique Industrielle, UMR 5305, Plateforme Fripharm, Faculté de Pharmacie, Université Claude Bernard Lyon 1, 8, avenue Rockefeller, F-69373 Lyon Cedex 08, France.

During the early months of the COVID-19 pandemic, the international medical product supply chain was tight, causing breaks in the availability of neuromuscular blocking agents essential for the treatment of patients in intensive care units. The present study describes the pharmaceutical development of an injectable 2 mg/mL solution of pancuronium bromide (PC) in a very short lapse of time. The sterile solution was compounded into a good manufacturing practice grade A clean room, filtered (0.

View Article and Find Full Text PDF

Present and validate an analytical model (AM) to calculate efficiency and spatial resolution of multi-parallel slit (MPS) and knife-edge slit (KES) cameras in the context of prompt gamma (PG) imaging in proton therapy, as well as perform a fair comparison between two prototypes of these cameras with their design specifications.Monte Carlo (MC) simulations with perfect (ideal) conditions were performed to validate the proposed AM, as well as simulations in realistic conditions for the comparison of both prototypes. The spatial resolution obtained from simulations was derived from reconstructed PG profiles.

View Article and Find Full Text PDF

Introduction: The reirradiation number increased due to systemic therapies and patient survival. Few guidelines regarding acceptable cumulative doses to organs at risk (OARs) and appropriate dose accumulation tools need, made reirradiation challenging. The survey objective was to present the French current technical and clinical practices in reirradiations.

View Article and Find Full Text PDF

Background And Objectives: This study provides a quantitative comparison of images created using gVirtualXray (gVXR) to both Monte Carlo (MC) and real images of clinically realistic phantoms. gVirtualXray is an open-source framework that relies on the Beer-Lambert law to simulate X-ray images in realtime on a graphics processor unit (GPU) using triangular meshes.

Methods: Images are generated with gVirtualXray and compared with a corresponding ground truth image of an anthropomorphic phantom: (i) an X-ray projection generated using a Monte Carlo simulation code, (ii) real digitally reconstructed radiographs (DRRs), (iii) computed tomography (CT) slices, and (iv) a real radiograph acquired with a clinical X-ray imaging system.

View Article and Find Full Text PDF