8 results match your criteria: "EXPLOR! Center[Affiliation]"
J Vasc Access
January 2025
EXPLOR! Center, Air Liquide Healthcare, Bagneux, France.
Background: Outpatient Parenteral Antibiotic Therapy (OPAT) services have expanded throughout the world thanks to elastomeric pumps (EP). Their flowrate is known to vary by ±15%. Treatment effectiveness and the organization of care at home may be impacted, especially with piperacillin/tazobactam infusion (TAZ).
View Article and Find Full Text PDFJ Diabetes Sci Technol
December 2024
Division of Dermatology, Department of Medicine, University of Washington School of Medicine, Seattle, WA, USA.
Ongoing innovation in diabetes technologies has led to the development of advanced tools such as automated insulin delivery (AID) systems that adjust insulin delivery in response to current and predicted glucose levels, residual insulin action, and other inputs (eg, meal and exercise announcements). However, infusion sets continue to be the "Achilles heel" of accurate and precise insulin delivery and continued device use. A recent study by Kalus et al (DERMIS Study) revealed higher vessel density and signals of inflammation by optical coherence tomography (OCT), in addition to increased inflammation, fat necrosis, fibrosis, and eosinophilic infiltration by histopathology.
View Article and Find Full Text PDFPLoS One
May 2022
Sorbonne Université, Brain Institute-ICM, Inserm, CNRS, Paris, France.
Body-Worn Sensors (BWS) provide reliable objective and continuous assessment of Parkinson's disease (PD) motor symptoms, but their implementation in clinical routine has not yet become widespread. Users' perceptions of BWS have not been explored. This study intended to evaluate the usability, user experience (UX), patients' perceptions of BWS, and health professionals' (HP) opinions on BWS monitoring.
View Article and Find Full Text PDFNPJ Parkinsons Dis
June 2021
Neurology Department, Pitié-Salpêtrière Hospital, AP-HP, Paris, France.
Long-term effects of continuous subcutaneous apomorphine infusion (CSAI) on health-related quality of life (HRQoL) and predictors of CSAI discontinuation are poorly known. Data from consecutive advanced Parkinson's disease patients treated in routine care were retrospectively collected over 24 months after CSAI initiation, with a focus on the 39-item Parkinson's disease questionnaire (PDQ-39). We determined predictors of CSAI discontinuation and HRQoL improvement using multiple regression analysis.
View Article and Find Full Text PDFDiabetes Care
July 2021
Department of Diabetology and Endocrinology, Lariboisière Hospital, Assistance Publique - Hôpitaux de Paris, Paris, France
Diabetes Technol Ther
June 2020
IMMEDIAB Lab UMRS1138, Institut National de la Santé et de la Recherche Médicale (INSERM), Paris, France.
Continuous subcutaneous insulin infusion (CSII) is a widely adopted treatment for type 1 diabetes and is a component of an artificial pancreas. CSII accuracy is essential for glycemic control, however, this metric has not been given sufficient study, especially at the range of the lowest basal rates (BRs), which are commonly used in a pediatric population and in closed-loop systems (CLSs). Our study presents accuracy results of four off-the-shelf CSII systems using a new accurate method for CSII system evaluation.
View Article and Find Full Text PDFDiabetes Technol Ther
October 2019
Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS 1138, Paris, France.
Insulin pump or continuous subcutaneous insulin infusion (CSII) system is a widely adopted contemporary treatment for type 1 diabetes and is a major component of an artificial pancreas (AP). CSII accuracy is essential for glycemic control and to-date such metric has not been given sufficient study, especially at the range of the lowest basal rate. The gold-standard assessment method IEC (International Electrotechnical Commission) 60601-2-24 has some limitations.
View Article and Find Full Text PDFBMC Pulm Med
February 2019
Service de Pneumologie et Réanimation Médicale (Département "R3S")AP-HP, Groupe Hospitalier Pitié-Salpêtrière Charles Foix, 47-83 boulevard de l'hôpital, F-75013, Paris, France.
Background: During invasive ventilation, the upper airway is bypassed and no longer participates in humidification of inspired gases, which is essential to avoid harmful consequences such as endotracheal tube occlusion. In the case of increased air flow, especially in the presence of leaks (intentional or unintentional), the humidification provided by humidifiers may become ineffective. The objective of this bench study was to evaluate the quality of humidification provided by heated humidifiers under various home ventilation conditions.
View Article and Find Full Text PDF