Choroidal thickness and choriocapillaris vascular density in myopic anisometropia.

Eye Vis (Lond)

December 2021

School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, 325027, Zhejiang, China.

Background: This study aims to examine interocular differences in the choroidal thickness and vascular density of the choriocapillaris in anisometropic myopes and to further explore the relationship between choroidal blood flow and myopia.

Methods: The sample comprised 44 participants with anisometropic myopia, aged 9 to 18 years, with normal best-corrected visual acuity. All participants underwent a series of examinations, including spherical equivalent refraction (SER) and axial length (AL), measured by a Lenstar optical biometer and optical coherence tomography angiography (OCTA) scanner.

View Article and Find Full Text PDF

Accuracy and safety of partial thickness femtosecond laser radial and arcuate keratotomy incisions in porcine eyes.

Eye Vis (Lond)

December 2021

Packer Research Associates, Inc., 1400 Bluebell Ave., Boulder, CO, 80302, USA.

Background: To evaluate the accuracy and safety of micro radial and arcuate keratotomy incisions constructed by a femtosecond laser system with a curved contact patient interface in porcine eyes.

Methods: Partial thickness micro radial and arcuate keratotomy incisions were constructed in porcine eyes with a femtosecond laser system and evaluated for precision of depth, quality, and consistency. Optical coherence tomography was used to determine the accuracy and precision of incision depth.

View Article and Find Full Text PDF

Peripheral refraction of myopic eyes with spectacle lenses correction and lens free emmetropes during accommodation.

Eye Vis (Lond)

December 2021

Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics (Optometry), University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal.

Purpose: To measure axial and off-axis refraction patterns in myopic eyes with spectacle lenses correction and lens free emmetropes in young healthy subjects at different target distances from 2.00 m (0.50 D) to 0.

View Article and Find Full Text PDF

Comparisons of corneal biomechanical and tomographic parameters among thin normal cornea, forme fruste keratoconus, and mild keratoconus.

Eye Vis (Lond)

November 2021

Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, 100069, China.

Background: To compare the dynamic corneal response (DCR) and tomographic parameters of thin normal cornea (TNC) with thinnest corneal thickness (TCT) (≤ 500 µm), forme fruste keratoconus (FFKC) and mild keratoconus (MKC) had their central corneal thickness (CCT) matched by Scheimpflug imaging (Pentacam) and corneal visualization Scheimpflug technology (Corvis ST).

Methods: CCT were matched in 50 eyes with FFKC, 50 eyes with MKC, and 53 TNC eyes with TCT ≤ 500 µm. The differences in DCR and tomographic parameters among the three groups were compared.

View Article and Find Full Text PDF

Background: The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up.

Methods: This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery.

View Article and Find Full Text PDF

Background: To examine the effectiveness of the use of machine learning for adapting an intraocular lens (IOL) power calculation for a patient group.

Methods: In this retrospective study, the clinical records of 1,611 eyes of 1,169 Japanese patients who received a single model of monofocal IOL (SN60WF, Alcon) at Miyata Eye Hospital were reviewed and analyzed. Using biometric metrics and postoperative refractions of 1211 eyes of 769 patients, constants of the SRK/T and Haigis formulas were optimized.

View Article and Find Full Text PDF

Background: To evaluate the long-term safety, efficacy, predictability, and stability of implantable collamer lens with a central hole (EVO ICL) implantation for correcting high myopia (HM) and super high myopia (SHM).

Methods: This prospective study evaluated 83 eyes of 46 patients who were divided into groups based on their spherical equivalent refractive error (SE): HM group (- 12 D ≤ SE < - 6 D) and SHM group (SE < - 12 D). They were followed up for 5 years after ICL implantation; assessments of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refractive error, axial length, intraocular pressure, corneal endothelial cell density, and vault were conducted, and a questionnaire was administered.

View Article and Find Full Text PDF

Purpose: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port.

Methods: This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery.

View Article and Find Full Text PDF

Visual acuity is correlated with ischemia and neurodegeneration in patients with early stages of diabetic retinopathy.

Eye Vis (Lond)

October 2021

School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan Road, Wenzhou, 325027, Zhejiang, China.

Purpose: We investigated the effects of retinal ischemia, neurodegeneration, and subclinical edema on best-corrected visual acuity (BCVA) in the early stages of diabetic retinopathy (DR).

Methods: Ischemia was evaluated by the microvascular parameters measured by optical coherence tomography angiography. Neurodegeneration and subclinical edema were identified by the intraretinal layer thickness obtained by optical coherence tomography.

View Article and Find Full Text PDF

Intravitreal corticosteroids for diabetic macular edema: a network meta-analysis of randomized controlled trials.

Eye Vis (Lond)

October 2021

Department of Ophthalmology, The Second Xiangya Hospital, Central South University, 139 Middle Renmin Road, Changsha, 410011, Hunan, China.

Background: To evaluate the efficacy and safety of different intravitreal corticosteroids for treating diabetic macular edema (DME).

Methods: Four databases were systematically searched for randomized controlled trials comparing different intravitreal corticosteroids for treating DME. The primary outcome was the change in best-corrected visual acuity (BCVA) within 6 months after the first injection (short-term BCVA).

View Article and Find Full Text PDF

Background: To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer.

Methods: This study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group); (b) 19 Miniwell; (c) 24 LENTIS Mplus LS-313 MF30; d) 33 LENTIS Mplus LS-313 MF15; (e) 17 AkkoLens Lumina; (f) 31 AT LISA Tri 839MP; (g) 20 Precizon Presbyopic; (h) 20 AcrySof IQ PanOptix; (i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer.

View Article and Find Full Text PDF

Purpose: Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment optical coherence tomography (AS-OCT).

Methods: In a prospective study, the lower punctum of 54 eyes of 29 patients implanted with perforated punctal plugs were examined using AS-OCT during the early postoperative period. Preoperative tear meniscus height (TMH) and tear meniscus area (TMA) were evaluated.

View Article and Find Full Text PDF

Background: The purpose of the study was to determine the advantages and disadvantages of epi-on corneal cross-linking (CXL) techniques compared with standard epi-off CXL.

Methods: We searched MEDLINE and EMBASE for randomized controlled trials (RCTs) and non-randomized studies of interventions (NRSIs) and we evaluated the selected papers according to the Cochrane risk of bias tool. We considered, as primary outcomes, average Kmax flattening, changes in uncorrected and corrected distance visual acuity (UDVA and CDVA); as secondary outcomes, we considered changes in pachymetry values and endothelial cell density (ECD).

View Article and Find Full Text PDF

Purpose: To report preliminary 6-month results on the use of the Preserflo Microshunt implant with and without Ologen in 50 pseudophakic eyes with moderate to advanced primary open-angle glaucoma (POAG).

Methods: Fifty pseudophakic eyes underwent ab externo Preserflo Microshunt implantation. Data was gathered retrospectively and two groups were then created, group A with application of MMC 0.

View Article and Find Full Text PDF

Background: To compare the arithmetic mean (M-SIA) and the summated vector mean of surgically induced astigmatism (SVM-SIA) according to the incision site after phakic intraocular lens (Visian implantable collamer lens (ICL), STAAR Surgical) implantation.

Methods: This study comprised 121 eyes of 121 consecutive patients undergoing ICL surgery through a 3.0-mm temporal or superior clear corneal incision.

View Article and Find Full Text PDF

Background: Myopia is the most common visual impairment in children and adolescents worldwide. This study described an economical and effective population-based screening pipeline and performed the project of a million scale children and adolescents myopia survey (CAMS), which will shed light on the further study of myopia from the level of epidemiology and precision medicine.

Methods: We developed a novel population-based screening pattern, an intelligent screening process and internet-based information transmission and analysis system to carry out the survey consisting of school children in Wenzhou, China.

View Article and Find Full Text PDF

Background: The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.).

Main Text: A literature search in several databases was carried out to identify those publications, both prospective, retrospective and/or comparative with other refractive surgery procedures, reporting optical outcomes of patients who were implanted with the V4c ICL model.

View Article and Find Full Text PDF

Purpose: To assess the rate of occurrence and the risk factors of postsurgical macular edema (PSME) in eyes with idiopathic epiretinal membrane (iERM) or full-thickness macular hole (FTMH).

Methods: Retrospective longitudinal analysis of all subjects scheduled for vitrectomy with or without combined cataract surgery over a 6-month period. Electronic medical charts and imaging data were analyzed preoperatively and at 1, 3 and 6 months after surgery.

View Article and Find Full Text PDF

Intravitreal brimonidine inhibits form-deprivation myopia in guinea pigs.

Eye Vis (Lond)

July 2021

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, 510060, China.

Background: The use of ocular hypotensive drugs has been reported to attenuate myopia progression. This study explores whether brimonidine can slow myopia progression in the guinea pig form-deprivation (FD) model.

Methods: Three-week-old pigmented male guinea pigs (Cavia porcellus) underwent monocular FD and were treated with 3 different methods of brimonidine administration (eye drops, subconjunctival or intravitreal injections).

View Article and Find Full Text PDF

Background: To identify biometric and implantable collamer lens (ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL.

Methods: This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL. Preoperatively, white-to-white (WTW), central keratometry (Kc) and central corneal thickness (CCT) were measured using the Pentacam.

View Article and Find Full Text PDF

Background: This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT).

Methods: This was a prospective cross-sectional study. We measured the intraocular pressure (IOP) in 145 eyes of 145 glaucoma patients in the sitting position using GAT, IcarePRO, and IC200.

View Article and Find Full Text PDF

Background: Fuchs endothelial corneal dystrophy is a hereditary disease and the most frequent cause of corneal transplantation in the worldwide. Its main clinical signs are an accelerated decrease in the number of endothelial cells, thickening of Descemet's membrane and formation of guttae in the extracellular matrix. The cornea's ability to maintain stromal dehydration is impaired, causing painful epithelial bullae and loss of vision at the point when the amount of corneal endothelial cells cannot be compensated.

View Article and Find Full Text PDF

Background: To assess the clinical outcomes of the Visian Implantable Collamer Lens (ICL) with a central port throughout 7 years of follow-up.

Methods: Eighty-four eyes of 52 patients were evaluated over a follow-up period of 7 years after V4c ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD) and vault were analysed.

View Article and Find Full Text PDF

Background: To investigate machine-learning (ML) algorithms to differentiate corneal biomechanical properties between different topographical stages of keratoconus (KC) by dynamic Scheimpflug tonometry (CST, Corvis ST, Oculus, Wetzlar, Germany). In the following, ML models were used to predict the severity in a training and validation dataset.

Methods: Three hundred and eighteen keratoconic and one hundred sixteen healthy eyes were included in this monocentric and cross-sectional pilot study.

View Article and Find Full Text PDF