8 results match your criteria: "Deutsches Kunststoff-Institut (German Institute for Polymers)[Affiliation]"
Size-exclusion chromatography with light scattering detection experiments conducted on poly(acrylic acid) neutralized to different degrees or using hydroxides with different counterions suggest that the same counterion and degree of neutralization is observed at the detector, irrespective of salt concentration, degree of neutralization and counterion at the time of injection. This strongly supports that during the chromatographic experiment the counterions of the polyelectrolyte are exchanged with those of the eluent, resulting in an effective dialysis of the polyelectrolyte solution during the size-exclusion chromatography experiment. Consequently, the refractive index increment determined by a refractive index detector equals the refractive index increment obtained after excessive dialysis against the pure eluent.
View Article and Find Full Text PDFJ Chromatogr A
February 2012
Deutsches Kunststoff-Institut (German Institute for Polymers), Schlossgartenstr. 6, D-64289 Darmstadt, Germany.
The retention behavior of a range of statistical poly(styrene/ethylacrylate) copolymers is investigated, in order to determine the possibility to predict retention volumes of these copolymers based on a suitable chromatographic retention model. It was found that the composition of elution in gradient chromatography of the copolymers is closely related to the eluent composition at which, in isocratic chromatography, the transition from elution in adsorption to exclusion mode occurs. For homopolymers this transition takes place at a critical eluent composition at which the molar mass dependence of elution volume vanishes.
View Article and Find Full Text PDFJ Chromatogr A
October 2011
Deutsches Kunststoff-Institut (German Institute for Polymers), Schlossgartenstrasse, D-64289 Darmstadt, Germany.
A gradient ranging from methanol to tetrahydrofuran (THF) was applied to a series of poly(methyl methacrylate) (PMMA) standards, using the recently developed concept of SEC-gradients. Contrasting to conventional gradients the samples eluted before the solvent, i.e.
View Article and Find Full Text PDFBlends of polystyrene (PS) and polyisoprene (PI) were analysed by on-line hyphenation of LC at critical conditions and (1) H-NMR. Chromatography at critical conditions was established for both PS and PI. At both critical conditions, a perfect separation into the blend components was achieved.
View Article and Find Full Text PDFA comprehensive two-dimensional liquid chromatography system was developed to precisely describe the molecular heterogeneity of fatty alcohol ethoxylates. The end-group functionality was analyzed by gradient HPLC while ethylene oxide oligomer distributions were characterized by liquid adsorption chromatography. A baseline separation of all functionality fractions irrespective of the ethylene oxide oligomer chain length was achieved on nonpolar X-Terra(®) C(18) with a methanol-water gradient, whereas an isocratic flow of isopropanol-water on a polar Chromolith(®) Si column gave a separation according to the oligomer chain length without interference of the end-group distribution.
View Article and Find Full Text PDFJ Chromatogr A
September 2007
Deutsches Kunststoff-Institut (German Institute for Polymers), Schlossgartenstr. 6, D-64289 Darmstadt, Germany.
The suitability of a retention model especially designed for polymers is investigated to describe and predict the chromatographic retention behavior of poly(methyl methacrylate)s as a function of mobile phase composition and gradient steepness. It is found that three simple yet rationally chosen chromatographic experiments suffice to extract the analyte specific model parameters necessary to calculate the retention volumes. This allows predicting accurate retention volumes based on a minimum number of initial experiments.
View Article and Find Full Text PDFJ Chromatogr A
October 2006
Deutsches Kunststoff-Institut (German Institute for Polymers), Schlossgartenstrasse 6, 64289 Darmstadt, Germany.
A large variety of hydrophilic copolymers is applied in different fields of chemical industry including bio, pharma and pharmaceutical applications. For example, poly(ethylene glycol)-poly(vinyl alcohol) graft copolymers that are used as tablet coatings are responsible for the controlled release of the active compounds. These copolymers are produced by grafting of vinyl acetate onto polyethylene glycol (PEG) and subsequent hydrolysis of the poly(ethylene glycol)-poly(vinyl acetate) graft copolymers.
View Article and Find Full Text PDFJ Chromatogr A
March 2004
Deutsches Kunststoff-Institut (German Institute for Polymers), Schlossgartenstr 6, Darmstadt D-64289, Germany.
Simulations of the distribution coefficients of linear polymers and regular combs with various spacings between the arms have been performed. The distribution coefficients were plotted as a function of the number of segments in order to compare the size exclusion chromatography (SEC)-elution behavior of combs relative to linear molecules. By comparing the simulated SEC-calibration curves it is possible to predict the elution behavior of comb-shaped polymers relative to linear ones.
View Article and Find Full Text PDF