20 results match your criteria: "Department of Science and Technology Centre on Biomolecular Electronics[Affiliation]"
J Mater Chem B
April 2016
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory, Dr K. S. Krishnan Marg, New Delhi 110012, India.
A reagent-free, low-cost and sensitive immunosensor has been fabricated using anti-apolipoprotein B (AAB) conjugated l-cysteine in situ capped cadmium sulfide quantum dots (CysCdS QDs) bound to nickel oxide nanorods (nNiO) for detection of low density lipoprotein (LDL) molecules in human serum samples. The structural and morphological properties of AAB conjugated CysCdS QDs and nNiO have been investigated using electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy and UV-visible techniques. In this immunosensor, the synthesized NiO nanorods act as mediators that allow the direct electron transfer due to their channeling effect resulting in a mediator-free biosensor.
View Article and Find Full Text PDFACS Appl Mater Interfaces
March 2016
Department of Biotechnology, Delhi Technological University, Shahbad Daulatpur, Main Bawana Road, Delhi 110042, India.
A label-free, highly reproducible, sensitive, and selective biosensor is proposed using antiapolipoprotein B 100 (AAB) functionalized mesoporous few-layer reduced graphene oxide and nickel oxide (rGO-NiO) nanocomposite for detection of low density lipoprotein (LDL) molecules. The formation of mesoporous rGO-NiO composite on indium tin oxide conductive electrode has been accomplished via electrophoretic technique using colloidal suspension of rGO sheets and NiO nanoparticles. This biosensor shows good stability obtained by surface conjugation of antibody AAB molecules with rGO-NiO matrix by EDC-NHS coupling chemistry.
View Article and Find Full Text PDFNanoscale
November 2014
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi-110012, India.
We present a novel and efficient nanoporous microfluidic biochip consisting of a functionalized chitosan/anatase titanium dioxide nanoparticles (antTiO2-CH) electrode integrated in a polydimethylsiloxane (PDMS) microchannel assembly. The electrode surface can be enzyme functionalized depending on the application. We studied in detail cholesterol sensing using the cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) functionalized chitosan supported mesoporous antTiO2-CH microfluidic electrode.
View Article and Find Full Text PDFAppl Biochem Biotechnol
October 2014
Department of Science and Technology Centre on Biomolecular Electronics, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India.
We have fabricated an immunosensor based on carbon nanotubes and chitosan (CNT-CH) composite for detection of low density lipoprotein (LDL) molecules via electrochemical impedance technique. The CNT-CH composite deposited on indium tin oxide (ITO)-coated glass electrode has been used to covalently interact with anti-apolipoprotein B (antibody: AAB) via a co-entrapment method. The biofunctionalization of AAB on carboxylated CNT-CH surface has been confirmed by Fourier transform infrared spectroscopic and electron microscopic studies.
View Article and Find Full Text PDFLangmuir
April 2014
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory , Dr. K. S. Krishnan Marg, New Delhi, Delhi 110012, India.
A label-free biosensor based on antiapolipoprotein B 100 functionalized-aminated reduced graphene oxide interface has been fabricated for detection of low density lipoprotein (LDL or lipid) cholesterol. The aminated reduced graphene oxide (NH2-rGO) based electrode surface is covalently functionalized with antiapolipoprotein B 100 (AAB or lipid) using EDC/NHS coupling chemistry. The lipid-lipid interactions at the NH2-rGO electrode surface have been investigated using electrochemical impedance spectroscopic technique.
View Article and Find Full Text PDFAnal Chem
February 2014
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory , Dr. K. S. Krishnan Marg, New Delhi, Delhi 110012, India.
We propose a label-free biosensor platform to investigate the binding kinetics using antigen-antibody interaction via electrochemical and surface plasmon resonance (SPR) techniques. The L-cysteine in situ capped cadmium sulfide (CdS; size < 7 nm) quantum dots (QDs) self-assembled on gold (Au) coated glass electrode have been covalently functionalized with apolipoprotein B-100 antibodies (AAB). This protein conjugated QDs-based electrode (AAB/CysCdS/Au) has been used to detect lipid (low density lipoprotein, LDL) biomolecules.
View Article and Find Full Text PDFSci Rep
September 2013
1] Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi-110012, India [2] Indian Institute of Technology Hyderabad, Ordnance Factory Estate, Yeddumailaram, Hyderabad, Andhra Pradesh 502205, India.
This report describes the fabrication of a novel microfluidics nanobiochip based on a composite comprising of nickel oxide nanoparticles (nNiO) and multiwalled carbon nanotubes (MWCNTs), as well as the chip's use in a biomedical application. This nanocomposite was integrated with polydimethylsiloxane (PDMS) microchannels, which were constructed using the photolithographic technique. A structural and morphological characterization of the fabricated microfluidics chip, which was functionalized with a bienzyme containing cholesterol oxidase (ChOx) and cholesterol esterase (ChEt), was accomplished using X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy.
View Article and Find Full Text PDFBiosens Bioelectron
December 2013
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India; Centre for Interdisciplinary Research in Basic Sciences, Jamia Millia Islamia, New Delhi 110025, India.
Nanostructured magnesium oxide (size<10nm) grafted carboxyl (COOH) functionalized multi-walled carbon nanotubes (nMgO-cMWCNTs) deposited electrophoretically onto indium tin oxide (ITO) coated glass electrode and have been utilized for Vibrio cholerae detection. Aminated 23 bases single stranded DNA (NH2-ssDNA) probe sequence (O1 gene) of V. cholerae has been covalently functionalized onto nMgO-cMWCNTs/ITO electrode surface using EDC-NHS chemistry.
View Article and Find Full Text PDFBiosens Bioelectron
July 2013
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, National Physical Laboratory (CSIR), Dr. K.S. Krishnan Marg, New Delhi 110012, India.
A novel organic-inorganic platform comprising of chitosan (CH) modified nanostructured magnesium oxide (nanoMgO) has been electrophoretically deposited on the indium-tin-oxide (ITO) substrate. The single stranded probe DNA (ssDNA) sequence of Vibrio cholerae has been covalently functionalized onto CH-nanoMgO/ITO surface. The cytotoxicity assay of nanoMgO particles, examined using human intestinal cell line (INT 407), reveals no significant cytotoxicity at the given doses in the range of 50-350 μg/mL.
View Article and Find Full Text PDFNanoscale
April 2013
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi-110012, India.
We present results of the studies relating to fabrication of a microfluidic biosensor chip based on nickel oxide nanorods (NRs-NiO) that is capable of directly measuring the concentration of total cholesterol in human blood through electrochemical detection. Using this chip we demonstrate, with high reliability and in a time efficient manner, the detection of cholesterol present in buffer solutions at clinically relevant concentrations. The microfluidic channel has been fabricated onto a nickel oxide nanorod-based electrode co-immobilized with cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) that serves as the working electrode.
View Article and Find Full Text PDFCarbohydr Polym
July 2012
Department of Physics, Motilal Nehru National Institute of Technology, Allahabad, Allahabad 211004, India.
In this article we report about the synthesis of superparamagnetic bare Fe3O4 nanostructures and core/shell (Fe3O4/alginate) nanocomposites by simple low-temperature based method at pH values 5, 9, and 14. The structural morphology and magnetic behavior of Fe3O4 nanostructures and core/shell (Fe3O4/alginate) nanocomposites (Fe3O4/alg NCs) have been investigated by X-ray diffractometer (XRD), Fourier transform infrared spectroscopy (FT-IR), Raman spectroscopy (RS), ultraviolet-visible (UV-vis) spectroscopy, transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX) and vibrating sample magnetometer (VSM). The particle size was calculated by TEM measurements and it turns out to be ∼10 nm and ∼14 nm for bare Fe3O4 nanoparticle and Fe3O4/alg NCs with core/shell structure, respectively.
View Article and Find Full Text PDFAnalyst
February 2012
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, National Physical Laboratory (CSIR), Dr K. S. Krishnan Marg, New Delhi, 110012, India.
Self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) has been investigated for immobilization of bi-enzymes (ChOx and ChEt) towards development of enzyme biosensors for detection of free and total cholesterol. This enzyme immobilized SAM surface has been characterized by scanning electron microscopy and electrochemical measurements. The results of electrochemical response studies reveal fast enzymatic reaction in phosphate buffer saline solution without using any artificial mediator.
View Article and Find Full Text PDFChem Soc Rev
February 2012
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, Materials Physics & Engineering Division, National Physical Laboratory (Council of Scientific & Industrial Research) Dr K. S. Krishnan Marg, New Delhi-110012, India.
Organization of biomolecules in two/three dimensional assemblies has recently aroused much interest in nanobiotechnology. In this context, the development of techniques for controlling spatial arrangement and orientation of the desired molecules to generate highly-ordered nanostructures in the form of a mono/multi layer is considered highly significant. The studies of monolayer films to date have focused on three distinct methods of preparation: (i) the Langmuir-Blodgett (LB) technique, involving the transfer of a monolayer assembled at the gas-liquid interface; (ii) self-assembly at the liquid-solid interface, based on spontaneous adsorption of desired molecules from a solution directly onto a solid surface; and (iii) Layer-by-layer (LBL) self-assembly at a liquid-solid interface, based on inter-layer electrostatic attractions for fabrication of multilayers.
View Article and Find Full Text PDFNanoscale
July 2011
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, National Physical Laboratory, New Delhi 110012, India.
Urease (Urs) and glutamate dehydrogenase (GLDH) have been covalently co-immobilized onto a self-assembled monolayer (SAM) comprising of 10-carboxy-1-decanthiol (CDT) via EDC-NHS chemistry deposited onto one of the two patterned gold (Au) electrodes for estimation of urea using poly(dimethylsiloxane) based microfluidic channels (2 cm × 200 μm × 200 μm). The CDT/Au and Urs-GLDH/CDT/Au electrodes have been characterized using Fourier transform infrared (FTIR) spectroscopy, contact angle (CA), atomic force microscopy (AFM) and electrochemical cyclic voltammetry (CV) techniques. The electrochemical response measurement of a Urs-GLDH/CDT/Au bioelectrode obtained as a function of urea concentration using CV yield linearity as 10 to 100 mg dl(-1), detection limit as 9 mg dl(-1) and high sensitivity as 7.
View Article and Find Full Text PDFBiosens Bioelectron
June 2011
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, Materials Physics & Engineering Division, National Physical Laboratory (Council of Scientific & Industrial Research), Dr. K. S. Krishnan Marg, New Delhi 110012, India.
Ochratoxin A (OTA) produced by Aspergillus Ochraceus and Penicillium verrucosum is a very dangerous toxin due to its toxic effects in human beings and its presence in a wide range of food products and cereals. A Langmuir-Blodgett (polyaniline (PANI)-stearic acid (SA)) film based highly sensitive and robust impedimetric aptasensor has been developed for ochratoxin A (OTA) detection. DNA Aptamer (Apt-DNA) specific to OTA has been covalently immobilized onto mixed Langmuir-Blodgett (LB) monolayer comprising of PANI-SA deposited onto indium tin-oxide (ITO) coated glass plates.
View Article and Find Full Text PDFBiosens Bioelectron
February 2011
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, Materials Physics and Engineering Division, National Physical Laboratory, Council of Scientific and Industrial Research, Dr KS Krishnan Marg, New Delhi 110012, India.
The present paper contains a detailed overview of recent advances relating to polyaniline (PANI) as a transducer material for biosensor applications. This conducting polymer provides enormous opportunities for binding biomolecules, tuning their bio-catalytic properties, rapid electron transfer and direct communication to produce a range of analytical signals and new analytical applications. Merging the specific nature of different biomolecules (enzymes, nucleic acids, antibodies, etc.
View Article and Find Full Text PDFElectrophoresis
November 2010
Department of Science and Technology Centre on Biomolecular Electronics, Biomedical Instrumentation Section, Materials Physics and Engineering Division, National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, India.
Polyaniline nanotube (PANI-NT) based films have been fabricated onto indium-tin-oxide (ITO) coated glass plates via electrophoretic technique. These PANI-NT/ITO electrodes have been utilized for covalent immobilization of cholesterol oxidase (ChOx) using glutaraldehyde (Glu) as cross-linker. Structural, morphological and electrochemical characterization of PANI-NT/ITO electrode and ChOx/Glu/PANI-NT/ITO bioelectrode have been done using FT-IR spectroscopy, SEM, electrochemical impedance spectroscopy and cyclic voltammetry techniques.
View Article and Find Full Text PDFNanoscale
December 2010
Department of Science and Technology Centre on Biomolecular Electronics, National Physical Laboratory (Council of Scientific Industrial Research), Dr K. S. Krishnan Marg, New Delhi, 110012, India.
A self-assembled monolayer (SAM) of 11-amino-1-undecanethiol (AUT) has been fabricated onto a gold (Au) substrate to co-immobilize anti-ochratoxin-A antibodies (AO-IgGs) and bovine serum albumin (BSA) to detect food borne mycotoxin [i.e., ochratoxin-A (OTA)].
View Article and Find Full Text PDFNanoscale
May 2010
Department of Science and Technology Centre on Biomolecular Electronics, National Physical Laboratory, CSIR, Dr K. S. Krishnan Marg, New Delhi 110012, India.
Polyaniline nanospheres (PANI-NS) prepared by morphological transformation of micelle polymerized camphorsulfonic acid (CSA) doped polyaniline nanotubes (PANI-NT) in the presence of ethylene glycol (EG) have been characterized by X-ray diffraction, atomic force microscopy, transmission electron microscopy, scanning electron microscopy, Fourier transform infra-red and UV-Visible spectroscopy. A PANI-NS (60-80 nm) film deposited onto an indium-tin-oxide (ITO) coated glass plate by the solution casting method has been utilized for covalent immobilization of biomolecules (cholesterol oxidase (ChOx)) viaN-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry for fabrication of a cholesterol biosensor. The ChOx/PANI-NS/ITO bioelectrode detects cholesterol in the concentration range of 25 to 500 mg dL(-1) with sensitivity of 1.
View Article and Find Full Text PDFJ Phys Chem B
October 2009
Department of Science and Technology Centre on Biomolecular Electronics, National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi-110012, India.
Human plasma low density lipoprotein (LDL) immunosensor based on surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) was fabricated by immobilizing antiapolipoprotein B (AAB) onto self-assembled monolayer (SAM) of 4-aminothiophenol (ATP). The AAB/ATP/Au immunosensor can detect LDL up to 0.252 microM (84 mg/dL) and 0.
View Article and Find Full Text PDF