1 results match your criteria: "Department of Orthopaedic Surgery University of Illinois Chicago Chicago Illinois USA.[Affiliation]"
Purpose: This paper investigates the biomechanical benefits of using hybrid constructs that combine cannulated screws with tension band wiring (TBW) cerclage compared to cannulated screws with anterior Variable Angle locking neutralisation plates (VA LNP). These enhancements can bear heavier loads and maintain the repaired patella's integrity, in contrast to traditional methods.
Method: Eighteen fresh-frozen human cadaver patellae were carefully fractured transversely at their midpoints using a saw.