640,631 results match your criteria: "CT; Griffin Hospital[Affiliation]"

The high compliance of the urinary bladder during filling is essential for its proper function, enabling it to accommodate significant volumetric increases with minimal rise in transmural pressure. This study aimed to elucidate the physical mechanisms underlying this phenomenon by analyzing the ex vivo filling process in rat from a fully voided state to complete distension, without preconditioning, using three complementary imaging modalities. High-resolution micro-CT at 10.

View Article and Find Full Text PDF

Deformable image registration (DIR) is an enabling technology in many diagnostic and therapeutic tasks. Despite this, DIR algorithms have limited clinical use, largely due to a lack of benchmark datasets for quality assurance during development. To support future algorithm development, here we introduce our first-of-its-kind abdominal CT DIR benchmark dataset, comprising large numbers of highly accurate landmark pairs on matching blood vessel bifurcations.

View Article and Find Full Text PDF

Medical imaging systems are commonly assessed and optimized by the use of objective measures of image quality (IQ). The performance of the ideal observer (IO) acting on imaging measurements has long been advocated as a figure-of-merit to guide the optimization of imaging systems. For computed imaging systems, the performance of the IO acting on imaging measurements also sets an upper bound on task-performance that no image reconstruction method can transcend.

View Article and Find Full Text PDF

Background: Thyroid-associated ophthalmopathy (TAO) is an autoimmune response to inflammation of the thyroid and orbital tissue. This research evaluated the efficacy of 99Tcm-DTPA orbital SPECT/CT combined with thyroid function test in radioactive iodine I-131 (RAI) treatment of TAO-hyperthyroidism.

Methods: We retrospectively studied clinical activity score (CAS), blood thyrotropine (TSH), free triiodothyronine (FT3), free thyroxine (FT4), thickness of extra-ocular muscle (EOM), and uptake rate (UR) of 99Tcm-DTPA orbital SPECT/CT of 43 patients after 6 months of treatment with 20 mCi RAI.

View Article and Find Full Text PDF

Revolutionizing ovarian cancer therapy by drug repositioning for accelerated and cost-effective treatments.

Front Oncol

January 2025

Laboratorio de Farmacogenética, UMIEZ, Facultad de Estudios Superiores Zaragoza, Universidad Nacional Autónoma de México, Ciudad de México, Mexico.

Drug repositioning, the practice of identifying novel applications for existing drugs beyond their originally intended medical indications, stands as a transformative strategy revolutionizing pharmaceutical productivity. In contrast to conventional drug development approaches, this innovative method has proven to be exceptionally effective. This is particularly relevant for cancer therapy, where the demand for groundbreaking treatments continues to grow.

View Article and Find Full Text PDF

Background: Whole-body magnetic resonance imaging (wbMRI) allows general assessment of systemic cancers including lymphomas without radiation burden.

Aim: To evaluate the diagnostic performance of wbMRI in the staging of diffuse large B-cell lymphoma (DLBCL), determine the value of individual MRI sequences, and assess patients' concerns with wbMRI.

Methods: In this single-center prospective study, adult patients newly diagnosed with systemic DLBCL underwent wbMRI on a 3T scanner [diffusion weighted images with background suppression (DWIBS), T2, short tau inversion recovery (STIR), contrast-enhanced T1] and fluorodeoxyglucose (F-FDG) positron emission tomography/computed tomography (PET/CT) (reference standard).

View Article and Find Full Text PDF

Trends in dentomaxillofacial radiology.

World J Radiol

January 2025

Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06500, Türkiye.

Oral and maxillofacial diagnostic imaging is of paramount importance in dental clinical diagnosis, treatment planning, and follow-up procedures. Periapical radiographic examination and numerous panoramic systems are used in routine clinical dental practice. Cone beam CT is widely used and currently the method of choice in oral and maxillofacial implantology, endodontics, maxillofacial surgery, periodontics, degenerative temporomandibular joint disease, orthodontics, airway studies, sleep disorders, and forensic dentistry.

View Article and Find Full Text PDF

Serum levels of the tumor marker CA 19-9 are widely utilized in the diagnosis and monitoring pancreatic and biliary malignancies. However, serum levels of CA 19-9 have also been reportedly elevated in non-malignant conditions. Here, we present the rare case of a 65-year-old woman with a history of gallbladder malignancy who was found to have a new hepatic lesion on surveillance CT with an associated elevation in CA 19-9 to 5,866 U/mL.

View Article and Find Full Text PDF

Black girls in the United States are disproportionately diagnosed with sexually transmitted infections (STIs), which can increase the risk of contracting HIV (human immunodeficiency virus), compared to adolescent girls of other races. Therefore, this study was designed to understand barriers to impactful HIV/STI and substance use prevention programmes for Black girls. Data was collected between October 2021 and June 2022 from twelve focus groups which included (N = 62) participants who identified as Black and female between the ages of 13 and 18 years old.

View Article and Find Full Text PDF

This study tested the impact of troughing on the detection rates of MB2 canals with and without calcifications. Traditional access cavities were prepared and the detection of MB2 canals was recorded in 200 maxillary molars selected based on micro-CT scans. In specimens, the MB2 orifice was not detected; troughing was performed.

View Article and Find Full Text PDF

Background And Objective: Yttrium-90 plays a significant role in managing drug-resistant inflammatory arthritis through radionuclide synovectomy, where the radioisotope is injected into the affected joint to alleviate pain and inflammation by targeting the synovial tissue. This study aims to evaluate the effectiveness and safety of Yttrium-90 hydroxyapatite radionuclide synovectomy in improving joint functionality, as judged by physicians, in patients with inflammatory arthritis who had not responded to conventional treatments.

Methods: Patients with inflammatory arthritis were recruited from the orthopedics department and referred to the nuclear medicine department for evaluation.

View Article and Find Full Text PDF

The human body consists of many different soft biological tissues that exhibit diverse microstructures and functions and experience diverse loading conditions. Yet, under many conditions, the mechanical behaviour of these tissues can be described well with similar nonlinearly elastic or inelastic constitutive relations, both in health and some diseases. Such constitutive relations are essential for performing nonlinear stress analyses, which in turn are critical for understanding physiology, pathophysiology and even clinical interventions, including surgery.

View Article and Find Full Text PDF

Computed tomographic features of clinically suspected rhinitis in domestic rabbits (Oryctolagus cuniculus).

Vet Rec

January 2025

Department of Small Animals Diagnostic Imaging, École Nationale Vétérinaire d'Alfort, Maisons-Alfort, France.

Background: The aim of this study was to characterise the computed tomographic (CT) findings in domestic rabbits with clinically suspected rhinitis and compare them with CT findings in rabbits without clinical signs of rhinitis.

Methods: CT images of rabbits that underwent a CT of the head were retrospectively reviewed and any CT abnormalities were described. Statistical analysis was performed to detect any association between the CT findings and clinical signs of rhinitis, and also to assess if there was any association between rhinitis and otitis media, otitis externa or dental disease.

View Article and Find Full Text PDF

Computed Tomographic Anatomy of the Head in Cockatiel (Nymphicus hollandicus).

Vet Med Sci

March 2025

Department of Basic Sciences, Faculty of Veterinary Medicine, Urmia Branch, Islamic Azad University, Urmia, Iran.

Background: Nowadays, computed tomography (CT) scanning is one of the most practical and precise diagnostic imaging methods that can be utilized to evaluate the head in birds.

Objectives: This study aimed to present the normal anatomical data of the head of the cockatiel (Nymphicus hollandicus) using the CT method. In this research, the features of this bird's head were investigated in terms of bones, joints, muscles, sinuses and other constituent tissues.

View Article and Find Full Text PDF

Study Design: A systematic literature review and consensus using Delphi method.

Objective: The aim was to formulate consensus recommendations regarding the natural history, diagnosis, classification and optimal treatment of Os Odontoideum with global applicability.

Summary Of Background: Os odontoideum (OO) is a rare anomaly of the cranio-vertebral junction (CVJ).

View Article and Find Full Text PDF

Triangular Margin: Reliable Imaging Feature of Fibrous Dysplasia in Long Bones?

J Comput Assist Tomogr

January 2025

Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital, Boston, MA.

Objective: To determine the utility of a triangular margin as an imaging diagnostic feature for fibrous dysplasia.

Materials And Methods: We retrospectively reviewed all surgically biopsied or managed benign and malignant bone tumors by a single orthopedic oncologist over 19 years (2003 to 2022). A musculoskeletal radiologist and an orthopedic oncologist, both with >10 years of experience, retrospectively evaluated all imaging in consensus.

View Article and Find Full Text PDF

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Objective: Early diagnosis of primary and metastatic lung nodules is critical for effective therapeutic planning. Manual delineation of lung nodules is not time-efficient and is prone to human error as well as interobserver and intraobserver variability. This study aimed to address the unmet need for an open-source computer-aided detection (CAD) system for 3D segmentation of lung and metastatic lung nodules along with radiomic feature extraction.

View Article and Find Full Text PDF

Purpose: The purpose of this work was to evaluate the image quality of a commercial CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO).

Methods: CT number, noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF), and noise power spectrum (NPS) were assessed using the ACR CT Accreditation phantom scanned with various acquisitions at 80 kV, 100 kV, 120 kV, and 135 kV, each with multiple CTDIvol values of 20 mGy, 40 mGy, and 65 mGy. Artifacts were evaluated in an anthropomorphic head phantom, a cadaver head, and in patient studies.

View Article and Find Full Text PDF

Objective: This study evaluated the performance of a deep learning-based vertebral compression fracture (VCF) detection tool in patients with incidental VCF. The purpose of this study was to validate this tool across multiple sites and multiple vendors.

Methods: This was a retrospective, multicenter, multinational blinded study using anonymized chest and abdominal CT scans performed for indications other than VCF in patients ≥50 years old.

View Article and Find Full Text PDF

Background: Treatment-related changes may occur due to radiation and temozolomide in glioblastoma and can mimic tumor progression on conventional MRI. DCE-MRI enables quantification of the extent of blood-brain barrier (BBB) disruption, providing information about areas of suspicious postcontrast T1 enhancement. We compared DCE-MRI processing methods for distinguishing true disease progression from pseudoprogression in high-grade gliomas (HGGs).

View Article and Find Full Text PDF

Objective: This study aims to identify factors associated with the detectability of the right adrenal vein (RAV) on preoperative contrast-enhanced CT scans of adrenal venous sampling (AVS) in the era of high-resolution CT (HRCT).

Materials And Methods: In this retrospective study, 36 patients (15 men and 21 women; mean age, 56 y) who underwent preoperative contrast-enhanced CT [11 patients in HRCT with 0.25 mm detector matrix (Cannon Medical Systems) and 25 patients in conventional multidetector CT with 0.

View Article and Find Full Text PDF

Objective: To explore the application of low-energy image in dual-energy spectral CT (DEsCT) combined with deep learning image reconstruction (DLIR) to improve inferior vena cava imaging.

Materials And Methods: Thirty patients with inferior vena cava syndrome underwent contrast-enhanced upper abdominal CT with routine dose, and the 40, 50, 60, 70, and 80 keV images in the delayed phase were first reconstructed with the ASiR-V40% algorithm. Image quality was evaluated both quantitatively [CT value, SD, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for inferior vena cava] and qualitatively to select an optimal energy level with the best image quality.

View Article and Find Full Text PDF

Objective: To confirm that saline sealing of the needle trace after computed tomography (CT)-guided lung biopsy reduces the incidence of pneumothorax and chest tube insertion, and to observe its effects on pulmonary hemorrhage and hemoptysis.

Materials And Methods: Patients who underwent CT-guided lung biopsy at our hospital between January 2018 and January 2024 were included in the study. Patients were divided into 2 groups according to whether the needle trace was sealed with saline after tissue sampling.

View Article and Find Full Text PDF

Background: With the widespread use of lumbar pedicle screws for internal fixation, the morphology of the screws and the surrounding tissues should be evaluated. The metal artifact reduction (MAR) technique can reduce the artifacts caused by pedicle screws, improve the quality of computed tomography (CT) images after pedicle fixation, and provide more imaging information to the clinic.

Purpose: To explore whether the MAR+ method, a projection-based algorithm for correcting metal artifacts through multiple iterative operations, can reduce metal artifacts and have an impact on the structure of the surrounding metal.

View Article and Find Full Text PDF