29 results match your criteria: "BG Trauma Center Ludwigshafen at the University of Heidelberg[Affiliation]"
J Clin Med
February 2024
BG Trauma Center Ludwigshafen at the University of Heidelberg, Clinic for Trauma and Orthopedic Surgery, Ludwig-Guttmann-Straße 13, 67071 Ludwigshafen, Germany.
JSES Int
September 2022
Evangelisches Krankenhaus, Clinic for Trauma and Orthopaedic Surgery, Bad Dürkheim, Germany.
Background: This study aimed to evaluate clinical, cosmetic, and strength midterm outcomes in arthroscopic biceps tenotomy and subpectoral biceps tenodesis using bicortical endobutton and interference screw.
Methods: In this retrospective study, inclusion criteria were long head of the biceps (LHB) pathologies treated either with tenotomy or an additional tenodesis. Postoperative assessment included Long Head of Biceps Score (LHBS), age-adjusted Constant-Murley Score, and Subjective Shoulder Value.
Arthrosc Sports Med Rehabil
June 2022
Steadman Philippon Research Institute, Vail, Colorado, U.S.A.
Purpose: To characterize the qualitative anatomy of posterior scapula structures encountered with the Judet approach and to perform a quantitative evaluation of these structures' anatomic locations, including their relationships to osseus landmarks to identify safe zones.
Methods: Twelve fresh-frozen cadaveric shoulders (mean age, 55.2 years; range 41-64 years; 5 left, 7 right) were dissected.
J Hand Surg Am
June 2023
Steadman Philippon Research Institute, Vail, Colorado; Steadman Clinic, Vail, Colorado. Electronic address:
Purpose: The purpose of this study was to compare, using a cadaveric model, the biomechanical properties of headless compression screws (HCSs) and HCSs augmented with a buttress plate (BP) in capitellar fractures.
Methods: Twenty pairs of fresh-frozen humeri (mean age, 46.3 years; range, 33-58 years) were used.
Sci Rep
November 2021
Clinic for Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
To compare outcomes, complications, revisions, and rates of implant removal of superior compared to anteroinferior plating in displaced midshaft clavicle fractures at mid-term follow-up. We retrospectively reviewed 79 patients who underwent operative treatment for displaced midshaft clavicle fractures (Group A: 28 patients with superior plating; Group B: 51 patients with anteroinferior plating) that were at least 2 years postoperatively. Adjusted Constant Score (aCS), Visual Analog Scale (VAS), and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score were compared.
View Article and Find Full Text PDFArthroscopy
September 2021
Steadman Philippon Research Institute, Vail, Colorado, U.S.A.; Steadman Clinic, Vail, Colorado, U.S.A.. Electronic address:
Purpose: To compare the biomechanical properties of metallic anchor (MA) and all-suture anchor (ASA) constructs in the anatomic reattachment of the lateral ulnar collateral ligament complex to its humeral insertion.
Methods: Twenty paired male human cadaveric elbows with a mean age of 46.3 years (range: 33-58 years) were used in this study.
Am J Sports Med
July 2021
The Steadman Clinic, Vail, Colorado, USA.
Background: Modern rotator cuff repair techniques demonstrate favorable early and midterm outcomes, but long-term results have yet to be reported.
Purpose: To determine 10-year outcomes and survivorship after arthroscopic double-row transosseous-equivalent (TOE) rotator cuff repair.
Study Design: Case series; Level of evidence 4.
Arthroscopy
October 2021
Steadman Philippon Research Institute, Vail, Colorado, U.S.A.; Steadman Clinic, Vail, Colorado, U.S.A.. Electronic address:
Purpose: The purposes of this study were to assess clinical and radiographic outcomes of arthroscopically-assisted, anatomic coracoclavicular ligament reconstruction using tendon allograft (AA-ACCR) for the treatment of Rockwood type III-V injuries at minimum 2-year follow-up and to perform subgroup analyses of clinical and radiographic outcomes for acute versus chronic and type III versus type IV-V injuries.
Methods: In this retrospective study of prospectively collected data, patients who underwent primary AA-ACCR for the treatment of type III-V dislocations and had minimum 2-year follow-up were included. Preoperative and postoperative patient-reported outcome scores (PROs) were collected, including American Shoulder and Elbow Surgeons score, Single Numeric Assessment Evaluation score, Short Form-12 Physical Component Summary, Quick Disabilities of the Arm Shoulder and Hand score, and patient satisfaction.
JSES Rev Rep Tech
February 2021
Steadman Philippon Research Institute, Vail, CO, USA.
Background: Total shoulder arthroplasty implant designs have continued to evolve over the years. One recent change has been the shortening of the humeral component to preserve bone stock and to facilitate revision surgery. Despite promising clinical results, radiographic bone adaptions occur frequently in short-stem total shoulder arthroplasty, and limited data exist on short-stem reverse shoulder arthroplasty (RSA).
View Article and Find Full Text PDFJ Shoulder Elbow Surg
August 2021
Department of Biomedical Engineering, Steadman Philippon Research Institute, Vail, CO, USA; The Steadman Clinic, Vail, CO, USA. Electronic address:
Background: A medialized center of rotation (COR) in reverse total shoulder arthroplasty (RTSA) comes with limitations such as scapular notching and reduced range of motion. To mitigate these effects, lateralization and inferiorization of the COR are performed, but may adversely affect deltoid muscle force. The study purposes were to measure the effect of RTSA with varying glenosphere configurations on (1) the COR and (2) deltoid force compared with intact shoulders and shoulders with massive posterosuperior rotator cuff tears (PS-RCT).
View Article and Find Full Text PDFJ Clin Med
October 2020
OCM (Orthopädische Chirurgie München), Steinerstrasse 6, 81369 Munich, Germany.
Background: The radiological phenomenon of subsidence following the implantation of uncemented short-stem reverse prostheses (USSP) has not yet been described. The purpose of this study was to describe the rate and potential risk factors for subsidence. We hypothesized that subsidence may be a frequent finding and that a subsidence of >5 mm (mm) is associated with an inferior clinical outcome.
View Article and Find Full Text PDFArthroscopy
February 2021
Steadman Clinic, Vail, Colorado, U.S.A.. Electronic address:
Purpose: To report clinical outcomes following arthroscopic suprascapular nerve (SSN) decompression for suprascapular neuropathy at the suprascapular and/or spinoglenoid notch in the absence of major concomitant pathology.
Methods: We retrospectively reviewed prospectively collected data of 19 patients who underwent SSN release at the suprascapular and/or spinoglenoid notch between April 2006 and August 2017 with ≥2 years of follow-up. Patients who underwent concomitant rotator cuff or labral repairs or had severe osteoarthritis were excluded.
J Am Acad Orthop Surg
June 2021
From Southern Oregon Orthopedics, Medford, OR (Dr. Denard), the Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, OR (Dr. Denard), Steadman Philippon Research Institute, Vail, CO (Dr. Nolte and Dr. Millett), BG Trauma Center Ludwigshafen at the University of Heidelberg, Clinic for Trauma and Orthopaedic Surgery, Ludwigshafen, Germany (Dr. Nolte), the The Steadman Clinic, Vail, CO (Dr. Millett), Naples Community Hospital (Dr. Adams and Mr. Rego), and Arthrex, Naples, FL (Dr. Adams, Dr. Liebler, Mr. Rego, and Dr. Higgins).
Introduction: Fixation of periprosthetic humeral fractures is most commonly obtained with steel-based wires or cables; however, disadvantages with these constructs are numerous. Suture-based cerclages offer the advantage of easy handling, less radiographic interference, and risk of metallosis, as well as decreased risk of cutting into the soft humeral bone. Therefore, the purpose of this study was to compare a suture-based cerclage to a stainless steel wire cerclage (SSWC) for stabilization of the humerus during shoulder arthroplasty.
View Article and Find Full Text PDFArch Orthop Trauma Surg
October 2021
Shoulder and Elbow Surgery, Arcus Sportklinik ARCUS Kliniken, Rastatter Str. 17-19, 75179, Pforzheim, Germany.
Introduction: The aim of the present study was to analyze the injury pattern and thus the dislocation mechanism after simple elbow dislocation using radiographs and magnetic resonance imaging (MRI) data sets.
Materials And Methods: The MRI data sets of 64 patients with a mean age of 44 years (18-77 years) were analyzed retrospectively. The inclusion criteria for the study were (1) radiograph with confirmed simple elbow dislocation, (2) low-energy trauma, (3) MRI of the affected elbow ≤ 3 weeks after trauma.
J Orthop Surg Res
January 2020
Clinic for Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen on the Rhine, Germany.
Background: The aim of the study was to analyze the functional and radiological outcome of Monteggia-like lesions in adults with unreconstructible fracture of the radial head and treatment with radial head arthroplasty.
Methods: Twenty-seven patients (mean age 56 years; range 36 to 79 years) with a Monteggia-like lesion and treatment with radial head replacement were included in this retrospective study. Minimum follow-up was 2 years.
Arch Orthop Trauma Surg
November 2019
BG Trauma Center Ludwigshafen at the University of Heidelberg, Clinic for Trauma and Orthopaedic Surgery, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen on the Rhine, Germany.
Introduction: The aim of this study was to evaluate a radiographic measurement method for assessment of overlengthening of the MoPyC radial head prosthesis.
Materials And Methods: Seven cadaver specimens were studied in ten stages: native specimen (1), radial head resection (2), and implantation of the MoPyC radial head prostheses (Bioprofile, Tornier, Montbonnot-Saint-Martin, France) in four increasing length (correct length, overlengthening of 1.5 mm, 3 mm, and 5 mm) with an intact medial collateral ligament (MCL 3-6) and following transection of the MCL (7-10).
Int Orthop
November 2019
Department of Trauma Surgery, BG Trauma Centre Murnau, Professor Küntscher Str. 8, 82418, Murnau, Germany.
Purpose: Pelvic ring fractures in the elderly gain increasing importance. Nonetheless, data on factors influencing treatment decision in relation to fracture classification, age, and the resulting treatment are still rare.
Methods: Prospectively collected data of the German Pelvic Injury Registry from patients aged over 65 years with a pelvic ring fracture were evaluated retrospectively.
J Shoulder Elbow Surg
August 2019
Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Cologne, Germany.
Background: Radial head fractures lead to persisting disability in a considerable number of cases. This study aimed to investigate their most common revision causes and procedures.
Methods: This multicenter retrospective study reviewed the cases of 466 adult patients who had undergone surgical revision after operative or nonoperative treatment of a radial head fracture.
Int J Med Robot
April 2019
Department for Trauma and Orthopedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, MINTOS-Medical Imaging and Navigation in Trauma and Orthopedic Surgery, AGiTEC-Working Group for Intraoperative Imaging and Technology of the DGOU, Ludwigshafen, Germany.
Background: Being a proven method in trauma and spine surgery, intraoperative 3D imaging (CBCT) has intrinsic deficits in difficult anatomy and with artifacts because of metal implants. The purpose of this study was to evaluate the use of intraoperative computed tomography (iCT) in acetabular surgery.
Methods: Ten cases of acetabular fractures that were operated with intraoperative use of the mobile CT scanner Brainlab Airo were analyzed.
Arch Orthop Trauma Surg
February 2019
Centre Orthopédique Santy, Lyon, France.
Introduction: The aim of the study was to evaluate the short-term clinical results of anatomic total shoulder arthroplasty with a short-stem prosthesis in primary osteoarthritis.
Materials And Methods: 65 shoulders with a mean age of 70 years (range 47-85 years) were available for minimum follow-up of 24 months. Clinical outcome was determined by range of motion, Constant score (CS) age and sex-adjusted Constant score (CS%), and subjective shoulder value (SSV).
J Orthop Surg Res
April 2018
Clinic for Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, MINTOS - Medical Imaging and Navigation in Trauma and Orthopaedic Surgery, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
Background: In acetabular fractures, the assessment of reduction and implant placement has limitations in conventional 2D intraoperative imaging. 3D imaging offers the opportunity to acquire CT-like images and thus to improve the results. However, clinical experience shows that even 3D imaging has limitations, especially regarding artifacts when implants are placed.
View Article and Find Full Text PDFJ Bone Joint Surg Am
April 2018
Clinic for Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, Ludwigshafen on the Rhine, Germany.
Background: The objective of our study was to analyze, under fluoroscopy, joint angulation of uninjured elbows and elbows with distinct induced collateral ligament injury.
Methods: Twelve elbow specimens were tested for varus and valgus joint angulation using 4 different examination methods (application of both varus and valgus stress by each of 2 examiners [Examiner 1 and Examiner 2] and application of 1 and 2 Nm of torque using a calibrated electric force scale) in 4 elbow positions (in full extension with 90° of supination and 90° of pronation, and in 30° of flexion with 90° of supination and 90° of pronation). Six elbow specimens were examined under varus stress at each of 5 sequential stages: (1) intact, (2) transection of the lateral ulnar collateral ligament (LUCL), (3) complete transection of the lateral collateral ligament complex (LCLC), (4) transection of the anterior aspect of the capsule (AC), and (5) transection of the medial collateral ligament (MCL).
Arch Orthop Trauma Surg
April 2018
Clinic for Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, MINTOS, Medical Imaging and Navigation in Trauma and Orthopaedic Surgery, Ludwig-Guttmann-Straße 13, 67071, Ludwigshafen am Rhein, Germany.
Introduction: In operative treatment of distal radius fractures satisfying outcome mainly relies on anatomical fracture reduction and correct implant placement. Examination with two-dimensional fluoroscopy may not provide reliable information about this. The aim of this study was to determine the effectiveness of additional intraoperative three-dimensional imaging in the operative treatment of comminuted distal radius fractures.
View Article and Find Full Text PDFJ Bone Joint Surg Am
June 2017
1Department of Trauma and Orthopaedic Surgery, BG Trauma Center Ludwigshafen at the University of Heidelberg, Ludwigshafen on the Rhine, Germany.
Arch Orthop Trauma Surg
May 2017
ATOS Clinic Heidelberg, German Joint Center, Shoulder and Elbow Surgery, Heidelberg, Germany.