289 results match your criteria: "Anthea Hospital GVM Care & Research[Affiliation]"

Introduction: Prevention of acute kidney injury during cardiopulmonary bypass (CPB) is still a challenge and has been the object of numerous studies. The incidence of acute kidney injury in the context of CPB is related to a multifactorial etiology. The role of hemadsorption in relation to cell-free hemoglobin and haptoglobin preservation is not well defined in the literature on CPB during cardiac surgery procedures.

View Article and Find Full Text PDF

Background: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated.

Aims: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems.

Methods: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy.

View Article and Find Full Text PDF

What is often omitted in contemporary myocardial protections.

Eur J Cardiothorac Surg

March 2024

Department of Cardiac Surgery, Anthea Hospital, GVM Care & Research, Bari, Italy.

View Article and Find Full Text PDF

Develop of endocavitary suction device for MiECC on minimally invasive mitral valve surgery.

J Cardiothorac Surg

March 2024

Department of Cardiac Surgery, GVM Care & Research, Anthea Hospital, Via Camillo Rosalba 35/37, Bari, 70124, Italy.

The minimally invasive extracorporeal circulation (MiECC) system was developed to minimize the contact of blood with air and foreign surfaces during conventional cardiopulmonary bypass (CPB). It is also aimed to reduce the inflammatory response by further increasing the biocompatibility of the components that make up the MiECC circuits. The Minithoracotomy (MTH) approach for mitral valve disease remains associated with prolonged operative times, but it is beneficial in terms of reduced postoperative complications (renal failure, atrial fibrillation, blood transfusion, wound infection), length of stay in intensive care unit (ICU) and in hospitalization, with finally a reduction in global cost.

View Article and Find Full Text PDF

Roller pump reverse flow-directed dynamic occlusiveness: towards precision in perfusion.

Interdiscip Cardiovasc Thorac Surg

March 2024

Division of Cardiac Surgery, Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy.

View Article and Find Full Text PDF

. The in-hospital reduction in low-density lipoprotein cholesterol (LDL-C) levels following acute coronary syndrome (ACS) is recommended in the current clinical guidelines. However, the efficacy of proprotein convertase subtilisin-kexin type 9 (PCSK9) inhibitors in those patients undergoing coronary artery bypass graft (CABG) has never been demonstrated.

View Article and Find Full Text PDF

The choice of the mechanical/biological heart valve prosthesis is a topic currently debated in the light of the transcatheter prosthetic models and the results obtained/expected with the new biological valve models. Consequently, it seems that increasingly younger patients would be indicated for an implantation of a biological prosthesis. This is also in order to improve the quality of life of patients who want to avoid oral anticoagulant therapy.

View Article and Find Full Text PDF

Objective: Transcatheter aortic valve implant (TAVI) is the gold standard for the high-surgical-risk group of patients with aortic valve disease and it is an alternative to surgery in patients at intermediate risk. Lethal complications can occur, and many of these are manageable only with emergent conversion to open heart surgery. We retrospectively evaluate the outcome of all patients undergoing TAVI in our departments and the impact of a complete cardiac rescue team to reduce 30-day mortality.

View Article and Find Full Text PDF

In the latest European guidelines for the management of valvular heart disease, mechanical valve prostheses maintain a strategic role, particularly for certain patient subsets and age groups. Despite the high number of devices implanted in clinical practice, particularly in non-European and North American regions, current scientific literature and debate seem to suggest a limited use of mechanical heart valves. The cardiac surgery community seems to be highly interested in biological and transcatheter valve prostheses but less interested in mechanical heart valves, including possible strategies for self-management of anticoagulation therapy.

View Article and Find Full Text PDF

Infective endocarditis (IE) on atrial septal defect (ASD) closure devices, while extremely rare, has been reported to be more frequent early after the procedure. We describe a case of late IE after percutaneous closure of patent foramen ovale (PFO). We also performed a literature review on this subject.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) is an almost totally cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related to the fluoroscopy time (FT), that has already been demonstrated to be associated with outcomes and complexity of coronary procedures. The aim of our study is to demonstrate the relationship between FT and the short-term outcomes after TAVR defined by to the Valve Academic Research Consortium (VARC)-2 and -3 consensus documents.

View Article and Find Full Text PDF

About different localization of hypoattenuated lesions following transcatheter aortic valve replacement.

Int J Cardiol

March 2024

Dept. of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care&Research, Palermo, Italy; University of Palermo, DICHIRONS, Palermo, Italy.

Article Synopsis
  • The study explores subclinical leaflet thrombosis in patients who underwent transcatheter aortic valve replacement, using multidetector computed tomography (MDCT) to identify lesions on leaflets and nearby structures.
  • Out of 50 patients followed for 12 months, 16% showed hypoattenuated lesions on leaflets, 18% in the anatomic sinus, and another 16% in subvalvular regions, highlighting a potential association with bicuspid valves.
  • The findings suggest these lesions can occur beyond just the leaflets, but the clinical significance of these lesions is still uncertain.
View Article and Find Full Text PDF

Evaluation of the anatomic sinus after transcatheter aortic valve replacement.

Int J Cardiol

February 2024

Dept. of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care&Research, Palermo, Italy; University of Palermo, DICHIRONS, Palermo, Italy.

Background: Following transcatheter aortic valve replacement (TAVI), the newly formed 'anatomic sinus'. may contribute to the formation of subclinical leaflet thrombosis (SLT).The evaluation of root geometry after TAVI is generally performed using multi-detector computed tomography (MDCT), and the role of transthoracic echocardiography (2D TTE) requires further validation.

View Article and Find Full Text PDF

Background: Vasoplegic syndrome is a form of vasodilatory shock that can occur before, during or after cardiopulmonary bypass (CPB). We introduce a strategy to reduce the incidence of early hypotension phenomena during Coronary Artery Bypass Graft (CABG) procedures.

Materials And Methods: In this prospective cohort study, 100 patients underwent elective CABG with two perioperative CPB settings.

View Article and Find Full Text PDF

Background: Cardiopulmonary bypass (CPB) techniques are becoming minimally invasive in clinical practice. The literature describes various extracorporeal techniques which seek to eliminate air-blood contact and reduce both hemodilution and the contact surface such as in Minimally invasive Extracorporeal Circulation (MiECC) and closed systems for CPB. However, the delivery of micro-embolic activity in the circuit and metabolic activity in terms of oxygen delivery for Goal-Directed Perfusion (GDP) management, in relation to the patient's blood volume and central venous pressure, have never been related and correlated.

View Article and Find Full Text PDF

Background: Criteria such as electrograms voltage or late potentials have been largely utilized in the past to help identify areas of substrate maps that are within the ventricular tachycardia (VT) isthmus; yet their specificity and positive predictive value are quite low. The Lumipoint fractionation tool of the Rhythmia system illuminates regions with fractionated electrograms irrespective of their timing and annotation. We aimed to ascertain whether the use of this tool can rapidly identify areas within VT isthmuses from substrate maps.

View Article and Find Full Text PDF

Self-Expandable Prosthesis Valve Adaptation: Non-Uniform Expansion and Stent Frame Decoupling.

Am J Cardiol

November 2023

Departments of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care & Research, Palermo, Italy; Department of Surgical, Oncological and Stomatological Sciences (DICHIRONS), University of Palermo, Palermo, Italy.

The incidence of non-uniform expansion in the context of the self-expandable transcatheter heart valve (THV) is little investigated, along with stent-frame decoupling, which is a form of stent adaptation, in which the lower part of the THV stent conforms to both the ellipticity of the left ventricle outflow tract and the native annulus while maintaining the higher part of the valve more circular. We analyzed post-implant multi-detector computed tomography scans in 50 patients. Prosthesis non-uniform expansion was assessed by computing the prosthesis eccentricity on 6 prespecified levels: (1) frame inflow, (2) native annulus, (3) leaflet inflow, (4) prosthesis waist, (5) leaflet outflow, and (6) frame outflow.

View Article and Find Full Text PDF

Background: The aims of this analysis were: to evaluate the impact of timing of ablation on the rate of atrial arrhythmias recurrence, verify if the timing of ablation impact differently in patients with paroxysmal and persistent AF.

Methods: Three thousand two hundred and five patients (60.5 ± 10 years, female 28.

View Article and Find Full Text PDF