Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/physrevb.50.205 | DOI Listing |
Clin Transl Radiat Oncol
March 2025
University Medical Center Utrecht, Department of Radiation Oncology, Utrecht, the Netherlands.
Background And Purpose: This study assessed the treatment time of online adaptive (i.e. Adapt-to-Shape, ATS) and virtual couch shift (i.
View Article and Find Full Text PDFFront Neurosci
January 2025
Department of Evidence-Based Medicine and Social Medicine, School of Public Health, Chengdu Medical College, Chengdu, Sichuan, China.
Introduction: Sleep deprivation (SD) significantly disrupts the homeostasis of the cardiac-brain axis, yet the neuromodulation effects of deep magnetic stimulation (DMS), a non-invasive and safe method, remain poorly understood.
Methods: Sixty healthy adult males were recruited for a 36-h SD study, they were assigned to the DMS group or the control group according to their individual willing. All individuals underwent heart sound measurements and functional magnetic resonance imaging scans at the experiment's onset and terminal points.
Background: Studies across multiple addictions have suggested that repetitive transcranial magnetic stimulation (rTMS) applied to the left dorsolateral prefrontal cortex (L-DLPFC) reduces cue-induced-craving (CIC), however there are no studies in treatment seeking participants with cannabis use disorder (CUD). In this secondary analysis of a previously completed trial, we explore whether a multi-session course of rTMS reduces CIC in CUD.
Methods: Seventy-one participants with ≥moderate CUD (age=30.
Nano Lett
January 2025
Department of Physics, Arizona State University, Tempe, Arizona 85287, United States.
Experimental detection of antiferromagnetic order in two-dimensional materials is a challenging task. Identifying multidomain antiferromagnetic textures via the current techniques is even more difficult. Therefore, we investigate the higher-order multipole moments in twisted bilayer MnPSe.
View Article and Find Full Text PDFNMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!