Unlabelled: We describe a technique for endobronchial surgery with the neodynium:yttium-aluminum-garnet laser, in which an insufflation catheter with side holes placed into the contralateral mainstem bronchus is used for high-frequency positive pressure ventilation. Thirty-five patients (45 procedures) were treated during general anesthesia using a rigid bronchoscope in combination with a fiberoptic bronchoscope. Perioperatively, oxygen saturation (SaO2), mean arterial pressure, and heart rate were recorded. SaO2 during the recovery period was comparable to that during the intraoperative period but was significantly (P < 0.05) higher than that before the induction of anesthesia. There was a considerable (> or = 5%) increase in SaO2 at the end of the treatment in six patients, which indicates that the recanalization of the treated airway was successful. Our data support the assumption that, during endobronchial resection, selective ventilation of the nonaffected lung was adequate; in addition, subcarinal placement of the insufflation catheter with side holes was advantageous. We conclude that this technique contributes to the prevention of lung complications during endobronchial laser surgery.
Implications: We describe a technique in which an insufflation catheter with side holes placed into the contralateral mainstem bronchus largely prevented inhalation of laser smoke and aspiration of blood and debris.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00000539-199902000-00013 | DOI Listing |
J Arrhythm
February 2025
Arrhythmia and Electrophysiology Unit, Department of Cardiology Hacettepe University Faculty of Medicine Ankara Turkey.
Circ Arrhythm Electrophysiol
December 2024
Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia (C.C., A.M.P., A.O., K.C., F.E.M., M.C.H.).
Cureus
October 2024
Department of Anesthesiology, Uniformed Services University of the Health Sciences, Bethesda, USA.
Korean J Anesthesiol
September 2024
Department of Anesthesiology and Pain Medicine, and Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.
Background: The Rapid-O2 oxygen insufflation device® (Rapid-O2) was designed primarily for rescue oxygenation in cannot intubate, cannot oxygenate (CICO) events; thus, hypercapnia is inevitable. Rapid-O2 was modified to enhance ventilation using the Venturi effect during expiration.
Methods: To determine the most effective combination of inner catheters (20 G, 18 G, 16 G, 14 G, and 2-mm inner diameter [ID] transtracheal catheter [TTC]) and insufflation catheters (16 G, 14 G, and 2-mm ID TTC) for achieving optimum ventilation, insufflating and expiratory flows were measured at an oxygen flow rate of 15 L/min.
Can J Anaesth
October 2024
Department of Anesthesiology and Pain Medicine, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!