Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/physrevd.32.2893 | DOI Listing |
Eur J Nucl Med Mol Imaging
January 2025
Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Otfried-Mueller-Str. 14, 72076, Tuebingen, Germany.
Purpose: Somatostatin receptor (SSTR)-PET is crucial for effective treatment stratification of neuroendocrine neoplasms (NENs). In highly proliferating or poorly differentiated NENs, dual-tracer approaches using additional [F]FDG PET can effectively identify SSTR-negative disease, usually requiring separate imaging sessions. We evaluated the feasibility of a one-day dual-tracer imaging protocol with a low activity [F]FDG PET followed by an SSTR-PET using the recently introduced [F]SiFAlin-TATE tracer in a long axial field-of-view (LAFOV) PET/CT scanner and its implications in patient management.
View Article and Find Full Text PDFInsights Imaging
January 2025
Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.
Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).
Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.
Sci Adv
January 2025
Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziadzka 5, 87-100 Torun, Poland.
Measuring low light absorption with combined uncertainty <1 per mil (‰) is crucial for many applications. Popular cavity ring-down spectroscopy can provide ultrahigh precision, below 0.01‰, but its accuracy is often worse than 5‰ due to inaccuracies in light intensity measurements.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA.
The spin-exotic hybrid meson π_{1}(1600) is predicted to have a large decay rate to the ωππ final state. Using 76.6 pb^{-1} of data collected with the GlueX detector, we measure the cross sections for the reactions γp→ωπ^{+}π^{-}p, γp→ωπ^{0}π^{0}p, and γp→ωπ^{-}π^{0}Δ^{++} in the range E_{γ}=8-10 GeV.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
University of California, Department of Physics, Berkeley, California 94720, USA.
The Mu2e and COMET experiments are expected to improve existing limits on charged lepton flavor violation (CLFV) by roughly 4 orders of magnitude. μ→e conversion experiments are typically optimized for electrons produced without nuclear excitation, as this maximizes the electron energy and minimizes backgrounds from the free decay of the muon. Here we argue that Mu2e and COMET will be able to extract additional constraints on CLFV from inelastic μ→e conversion, given the ^{27}Al target they have chosen and backgrounds they anticipate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!