Download full-text PDF

Source
http://dx.doi.org/10.1103/physrevb.33.6057DOI Listing

Publication Analysis

Top Keywords

microscopic calculations
4
calculations excitation
4
excitation spectrum
4
spectrum 3he
4
3he impurity
4
impurity liquid
4
liquid 4he
4
microscopic
1
excitation
1
spectrum
1

Similar Publications

We recently demonstrated polarisation differential phase contrast microscopy () as a robust, low-cost single-shot implementation of (semi)quantitative phase imaging based on differential phase microscopy. utilises a polarisation-sensitive camera to simultaneously acquire four obliquely transilluminated images from which phase images mapping spatial variation of optical path difference can be calculated. microscopy can be implemented on existing or bespoke microscopes and can utilise radiation at a wide range of visible to near infrared wavelengths and so is straightforward to integrate with fluorescence microscopy.

View Article and Find Full Text PDF

Since water is both a product and a common reactant impurity in the (partial) methanol oxidation to methyl formate (MeFo) on gold, its effect on the isothermal selectivity to methyl formate was investigated under well-defined single-collision conditions employing pulsed molecular beam experiments and in situ IRAS measurements. Both a flat Au(111) and a stepped Au(332) surface were used as model catalysts to elucidate how water affects the reactivity of low-coordinated step sites as compared to (111) terrace sites employing a range of reaction conditions. The interactions of water with methanol/methoxy as well as with oxygen species are addressed.

View Article and Find Full Text PDF

In living organisms, the natural motion caused by heartbeat, breathing, or muscle movements leads to the deformation of tissue caused by translation and stretching of the tissue structure. This effect results in the displacement or deformation of the plane of observation for intravital microscopy and causes motion-induced aberrations of the resulting image data. This, in turn, places severe limitations on the time during which specific events can be observed in intravital imaging experiments.

View Article and Find Full Text PDF

Optical glass selection is an important research object in optical design, which is an important way to aberration correction. However, these methods to our knowledge either do not correct aberration well or consume too much time. To efficiently solve the apochromatic problems in optical design, this paper presents what we believe to be a novel automatic optimization method for discontinuous optical glass based on auto glass selection (AGS).

View Article and Find Full Text PDF

Quantitative phase imaging (QPI) has become a valuable tool in the field of biomedical research due to its ability to quantify refractive index variations of live cells and tissues. For example, three-dimensional differential phase contrast (3D DPC) imaging uses through-focus images captured under different illumination patterns deconvoluted with a computed 3D phase transfer function (PTF) to reconstruct the 3D refractive index. In conventional 3D DPC with semi-circular illumination, partially spatially coherent illumination often diminishes phase contrast, exacerbating inherent noise, and can lead to a large number of zero values in the 3D PTF, resulting in strong low-frequency artifacts and deteriorating imaging resolution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!