Background: The purpose of this article was to evaluate the accuracy and reproducibility of spiral computed tomography (CT) and the curved line and cubic spline algorithms in measuring liver volume.

Methods: Spiral CT was performed in phantoms, cadaveric liver specimens, and 35 live human subjects (19 healthy volunteers and 16 patients). Images were transferred to a workstation, and volumes were measured by two observers. One observer repeated the measurements at a separate sitting.

Results: The correlation between the CT measurement and the gold standard measurement of the cadaveric livers was very strong (r = 0.94). For the live human subjects, the intraobserver and interobserver correlations were extremely high (r = 0.999 and 0.997, respectively). The mean difference in liver volume measurements between the separate observations was 1%.

Conclusion: The accuracy and reproducibility of this method of assessing liver volume are very high.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s002619900441DOI Listing

Publication Analysis

Top Keywords

liver volume
12
curved cubic
8
cubic spline
8
spline algorithms
8
accuracy reproducibility
8
live human
8
human subjects
8
measurements separate
8
measurement liver
4
volume spiral
4

Similar Publications

Background: The current subclassification of steatotic liver disease (SLD) relies on validated questionnaires, such as Alcohol Use Disorders Identification Test (AUDIT) and Lifetime Drinking History (LDH), which, while useful, are impractical and lack precision for their use in routine clinical practice. Phosphatidylethanol (PEth) is a quantitative, objective alcohol biomarker with high sensitivity and specificity.

Aims: To assess the diagnostic accuracy of PEth for differentiating metabolic dysfunction and alcohol-associated liver disease (MetALD) from metabolic dysfunction-associated steatotic liver disease (MASLD) in a large, population-based, prospective, multiethnic cohort of individuals with overweight or obesity.

View Article and Find Full Text PDF

The impact of various neurodegenerative diseases on the retina has been investigated in recent years using optical coherence tomography (OCT). Epilepsy, classified as a neurodegenerative disorder, has been indicated to affect the structural integrity of the retina. Moreover, there is ongoing debate regarding the relative contribution of disease pathogenesis and the consumption of anti-epileptic drugs (AEDs) to these retinal changes.

View Article and Find Full Text PDF

Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).

Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.

View Article and Find Full Text PDF

Background: Roux-en-Y gastric bypass may present long-term complications that require revisional surgery or even reversal to normal anatomy. Data on the indications, surgical technique, and outcomes of RYGB reversal remain scarce.

Methods: We identified 48 cases of RYGB reversals with complete 90-day follow-up within a multi-centric international retrospective database of elective secondary bariatric surgery.

View Article and Find Full Text PDF

Lung Clearance Index: A Sensitive Measure of Airway Function Improvement in Adolescents After Weight Loss from Bariatric Surgery.

Respir Med

January 2025

Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Clalit Health Services, Dan Petah Tikva District, Petah Tikva, Israel. Electronic address:

Background: Morbid obesity in adolescents impacts respiratory function, often leading to reduced lung volume and obstructive ventilatory defects. However, standard spirometric values frequently remain within normal ranges.

Objectives: We hypothesized that Lung Clearance Index (LCI) is a more sensitive marker for detecting airway dysfunction in adolescents with morbid obesity than conventional lung function tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!