Cyclosiloxanes produce fatal liver and lung damage in mice.

Environ Health Perspect

Department of Pathology, Baylor College of Medicine, Houston, TX 77030 USA.

Published: February 1999

To examine the toxicity of cyclosiloxanes (CSs), the predominant low molecular weight cyclic silicones found in breast implants, we injected female CD-1 mice intraperitoneally with different doses of distillate (3.5-35 g/kg body weight) containing cyclosiloxane D3 (hexamethylcyclotrisiloxane; CS-D3), cyclosiloxane D4 (octamethylcyclotetrasiloxane; CS-D4), cyclosiloxane D5 (decamethylcyclopentasiloxane; CS-D5), and cyclosiloxane D6 (dodecamethylcyclohexasiloxane; CS-D6). The distillate was found to be lethal and all the mice injected with 35 g/kg died within 5-8 days. The median lethal dose (LD50) for distillate was estimated to be approximately 28 g/kg. These mice developed inflammatory lesions of the lung and liver as well as liver cell necrosis with elevated serum levels of alanine aminotransferase, aspartate aminotransferase, and lactic acid dehydrogenase. Administration of CS-D4 alone also produced lethality in these mice with an LD50 of 6-7 g/kg. CS-D4-treated mice also exhibited pulmonary and hepatic lesions and elevated serum enzymes. Analysis of LD50 data indicates that CS-D4 is about as toxic as carbon tetrachloride or trichloroethylene. We measured hydroxyl radical formation in CS-D4-treated mice and found increases of approximately 20-fold in liver and approximately 7-fold in lung on day 4 following injection. Our findings are significant because in vitro experiments have demonstrated that CSs can migrate out of breast implants, and in mouse experiments CSs have been shown to be widely distributed in many organs after a single subcutaneous injection and to persist for at least a year.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1566344PMC
http://dx.doi.org/10.1289/ehp.99107161DOI Listing

Publication Analysis

Top Keywords

breast implants
8
elevated serum
8
cs-d4-treated mice
8
mice
7
cyclosiloxanes produce
4
produce fatal
4
liver
4
fatal liver
4
liver lung
4
lung damage
4

Similar Publications

Increased FGF-19 levels following explantation in women with breast implant illness.

Sci Rep

January 2025

Section General Internal Medicine, Department of Internal Medicine, Amsterdam University Medical Centres, Amsterdam, The Netherlands.

Breast Implant Illness (BII) is characterized by a cluster of systemic and local symptoms affecting a subset of women with silicone breast implants. While symptom improvement is frequently observed following implant removal, the underlying mechanisms remain poorly understood, and the absence of reliable biomarkers complicates clinical decision-making. Here, we investigate inflammatory protein profiles in 43 women with BII, comparing pre- and post-explantation levels using the Olink Target 96 Inflammation panel and Meso Scale Discovery technology for absolute quantification.

View Article and Find Full Text PDF

Reconstructed breast with silicone breast implants (SBIs) after nipple-sparing mastectomy (NSM) provides high patient satisfaction from a cosmetic point of view, but low patient satisfaction with respect to hypoesthesia of the reconstructed breast, and reinnervation is required. Currently, few reports are available on reinnervation in breast reconstruction with implants, and detailed data on desensitization of reconstructed breasts are lacking. Therefore, we examined perceptual data after NSM with respect to reinnervation.

View Article and Find Full Text PDF

Breast implants were first introduced in the 1960s and have long been used for augmentation and reconstructive breast surgery. More recently, fat grafting for breast augmentation has gained popularity due to the 'natural' outcome and lack of implant-related complications. The aim of this study was to conduct a systematic review and meta-analysis comparing patient-related outcome measures between fat grafting and implant-based primary augmentation using the validated BREAST-Q questionnaire.

View Article and Find Full Text PDF

The single port robotic nipple sparing mastectomy (SPrNSM) was recently introduced. This approach is safe and has led to favorable outcomes in relation to cosmetic result, patient satisfaction, and breast sensation. The typical reconstruction with all robotic nipple sparing mastectomies is implant based; however, this is not always what a patient desires.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!