Several filters specific for respiratory function tests have been on the market for several years. Recommended by the manufacturers to avoid contaminating the equipment and thus improve patient safety, these filters require a considerable financial investment. We studied the passage of diluted blood into artificial saliva in a patient model simulating inspiration tests and rapid forced expiration to assess the retention capacity of three filters used for respiratory function tests: Multi SPIRO MI-90016 (MultiSPIRO), PF 30S (Pall Biomedical) and Spirobac (Dar. S.p.A). The mean percentage of passage was 1.48% through the MI-90016 filter, 57.15% through the PF 30 S filter and 70.45% through the Spirobac filter. These findings provide further elements for choosing filters for respiratory function tests. Indeed, despite the manufacturers' commercial arguments, the technical documents provided do not give necessary information on the filtering capacity of the filters on the market. We have observed that two out of the three filters tested do no meet the standards expected by clinicians.

Download full-text PDF

Source

Publication Analysis

Top Keywords

respiratory function
16
three filters
12
filters respiratory
12
function tests
12
filters
7
[assessment three
4
respiratory
4
function
4
function tests]
4
tests] filters
4

Similar Publications

The aim of the study was to find whether certain meaningful moments in the learning process are noticeable through features of voice and how acoustic voice analyses can be utilized in learning research. The material consisted of recordings of nine university students as they were completing tasks concerning direct electric circuits as part of their course of teacher education in physics. Prosodic features of voice-fundamental frequency (F0), sound pressure level (SPL), acoustic voice quality measured by LTAS, and pausing-were investigated.

View Article and Find Full Text PDF

Mathematical and statistical methods are invaluable in epidemiological investigations, enhancing our understanding of disease transmission dynamics and informing effective control measures. In this study, we presented a method to estimate transmissibility using patient-level data, with application to the 2015 MERS outbreak at Pyeongtaek St. Mary's Hospital, the Republic of Korea.

View Article and Find Full Text PDF

Low agreement and frequent invalid controls in two SARS-CoV-2 T-cell assays in people with compromised immune function.

PLoS One

January 2025

Division of Clinical Epidemiology, Department of Clinical Research, University Hospital Basel, University of Basel, Basel, Switzerland.

T-cell response plays an important role in SARS-CoV-2 immunogenicity. For people living with HIV (PWH) and solid organ transplant (SOT) recipients there is limited evidence on the reliability of commercially available T-cell tests. We assessed 173 blood samples from 81 participants (62 samples from 35 PWH; 111 samples from 46 SOT recipients [lung and kidney]) with two commercial SARS-CoV-2 Interferon-γ (IFN-γ) release assays (IGRA; SARS-CoV-2 IGRA by Euroimmun, and IGRA SARS-CoV-2 by Roche).

View Article and Find Full Text PDF

Complex biological systems undergo sudden transitions in their state, which are often preceded by a critical slowing down of dynamics. This results in longer recovery times as systems approach transitions, quantified as an increase in measures such as the autocorrelation and variance. In this study, we analysed paediatric patients in intensive care for whom mechanical ventilation was discontinued through removal of the endotracheal tube (extubation).

View Article and Find Full Text PDF

Background: The efficacy and safety of ensifentrine, a novel PDE3/PDE4 inhibitor, were previously evaluated in the ENHANCE-1 (NCT04535986) and ENHANCE-2 (NCT04542057) trials. Here, we present a pooled post-hoc subgroup analysis of patients according to background chronic obstructive pulmonary disease (COPD) maintenance medication regimens.

Objective: This analysis aimed to explore the efficacy and safety of ensifentrine in patients receiving long-acting muscarinic antagonists (LAMA) or long-acting beta-agonists with inhaled corticosteroids (LABA + ICS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!