Study Design: A high-resolution strain measurement technique was applied to axially loaded parasagittal sections from thoracic spinal segments.
Objectives: To establish a new experimental technique, develop data analysis procedures, characterize intrasample shear strain distributions, and measure intersample variability within a group of morphologically diverse samples.
Summary Of Background Data: Compression of intact vertebral bodies yields structural stiffness and strength, but not strain patterns within the trabecular bone. Finite element models yield trabecular strains but require uncertain boundary conditions and material properties.
Methods: Six spinal segments (T8-T10) were sliced in parasagittal sections 6-mm thick. Axial compression was applied in 25-N increments up to sample failure, then the load was removed. Contact radiographs of the samples were made at each loading level. Strain distributions within the central vertebral body were measured from the contact radiographs by an image correlation procedure.
Results: Intrasample shear strain probability distributions were log-normal at all load levels. Shear strains were concentrated directly inferior to the superior end-plate and adjacent to the anterior cortex, in regions where fractures are commonly seen clinically. Load removal restored overall sample shape, but measurable residual strains remained.
Conclusions: This experimental model is a suitable means of studying low-energy vertebral fractures. The methods of data interpretation are consistent and reliable, and strain patterns correlate with clinical fracture patterns. Quantification of intersample variability provides guidelines for the design of future experiments, and the strain patterns form a basis for validation of finite element models. The results imply that strain uniformity is an important criterion in assessing risk of vertebral failure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00007632-199901010-00004 | DOI Listing |
J Med Microbiol
January 2025
NIHR Health Protection Research Unit in Gastrointestinal Infections, University of Liverpool, Liverpool, UK.
Diarrhoeagenic (DEC) pathotypes are defined by genes located on mobile genetic elements, and more than one definitive pathogenicity gene may be present in the same strain. In August 2022, UK Health Security Agency (UKHSA) surveillance systems detected an outbreak of hybrid Shiga toxin-producing /enterotoxigenic (STEC-ETEC) serotype O101:H33 harbouring both Shiga toxin () and heat-stable toxin (). These hybrid strains of DEC are a public health concern, as they are often associated with enhanced pathogenicity.
View Article and Find Full Text PDFFront Microbiol
January 2025
College of Veterinary Medicine, Gansu Agricultural University, Lanzhou, China.
is an opportunistic pathogen that can infect humans, animals and aquatic species, which is widely distributed in different aquatic environments and products. In recent years, with the rapid expansion of intensive aquaculture, the disease caused by has occurred. This study aims to understand the pathogenic characteristics of and provide scientific basis for the prevention and control of the epidemic.
View Article and Find Full Text PDFFront Microbiol
January 2025
Guangdong Ocean University, Zhanjiang, China.
H4Nx avian influenza viruses (AIVs) have been isolated from wild birds and poultry and can also cross the species barrier to infect mammals (pigs and muskrats). The widespread presence of these viruses in wild birds and poultry and their ability to be transmitted interspecies make them an undeniable hazard to the poultry farming industry. In the present study, we collected fecal and swab samples from wild birds and poultry in Guangdong Province from January 2019 to March 2024, and various subtypes of AIVs were isolated, including 19 strains of H4 subtype AIVs.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Physical Therapy, University of Delaware, Newark, Delaware, USA.
Background: Anterior cruciate ligament reconstruction (ACLR) often involves harvesting a bone-patellar tendon-bone (BPTB) autograft. How graft harvest affects tendon strain across the 3 distinct regions (medial, lateral, and central) is not known.
Purpose: To (1) quantify strain in the 3 regions of the patellar tendon during 60% of maximum voluntary isometric contraction (MVIC) in 90° of knee flexion and (2) assess how effort level in 2 different knee joint angles (60° and 90°) impacts strain in the medial and lateral regions of the patellar tendon, in 2 cohorts of patients after ACLR using a BPTB autograft (one group <24 months after surgery and another group ≥24 months after surgery).
Sci Rep
January 2025
School of Mines, China University of Mining and Technology, No.1 Daxue Rd, Xuzhou, 221116, China.
Pillar stability has garnered significant attention owing to the effects of pillars on coal resource recovery rate, coal pillar stability, and coal bump risk. This study examined the roadway stability control principles of conventional and yield coal pillars. The conventional coal pillars were designed as load-bearing structures with a high load-bearing capacity to carry most of the abutment load, while yield coal pillars were designed as buffer structures for transferring rapidly increasing abutment loads to adjacent solid coal ribs by progressive deformation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!