To investigate the parenchymal units in the liver of the rat three-dimensionally, 15 micrometer cryosections were used for the demonstration of glucose-6-phosphatase (G6Pase) activity to visualize the borders of the individual units. Together with the supplying and draining vessels, they were traced through a sequence of 146 sections and reconstructed. A cone-shaped secondary unit with a height of 2.1 mm and a volume of 3.3 mm3 was reconstructed. It was "covered" by a continuous vascular surface, consisting of portal tracts and vascular septa, connecting the portal venular branches. The secondary unit was subdivided by portal tracts and vascular septa, and by branches of a draining central venular tree into 14 primary units. Most of them were tri- to heptahedral in shape. The height varied between 330 and 840 micrometer, and the volume varied between 0.094 and 0.621 mm3. The branches of the portal venular tree, with diameters from 28 +/- 5 micrometer to 61 +/- 14 micrometer, were oriented preferentially along the vertical axis of the units. Most of the primary units were drained by single branches of the central venular tree, located in the center and oriented along the vertical axis of the units. Vessel diameters ranged from 62 +/- 14 micrometer to 216 +/- 9 micrometer. The average length of the sinusoids was 355 +/- 3 micrometer. From the results of this reconstruction study, it was concluded that the concept of the liver acinus cannot be applied to the liver of the rat.

Download full-text PDF

Source
http://dx.doi.org/10.1002/hep.510290243DOI Listing

Publication Analysis

Top Keywords

+/- micrometer
20
liver rat
12
venular tree
12
parenchymal units
8
units liver
8
secondary unit
8
portal tracts
8
tracts vascular
8
vascular septa
8
portal venular
8

Similar Publications

Background: Elemental analysis of teeth allows for exposure assessment during critical windows of development and is increasingly used to link early life exposures and health. The measurement of inorganic elements in teeth is challenging; laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is the most widely used technique.

Objective: Both synchrotron x-ray fluorescence (SXRF) and LA-ICP-MS have the capability to measure elemental distributions in teeth with each having distinct advantages and disadvantages.

View Article and Find Full Text PDF

Ion beam induced secondary electron tomography of acrylonitrile-styrene-acrylate/polycarbonate polymer blends for fused filament fabrication and injection moulding.

Sci Rep

January 2025

Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Orgánica, IMEYMAT, Universidad de Cádiz, Campus Río San Pedro, 11510, Puerto Real, Cádiz, Spain.

Polymer blending is an interesting strategy to broaden the combination of properties available for a variety of applications. To understand the behaviour of the new materials obtained as well as the influence of the fabrication parameters used, methods to analyse the distribution of polymers in the blend with resolution below the micrometer are required. In this work, we demonstrate the capability of focused ion beam (FIB) tomography to provide 3D information of the polymer distribution in objects obtained by blending acrylonitrile-styrene-acrylate (ASA) with polycarbonate (PC) (50 wt%), fabricated by Fused Filament Fabrication (FFF) and by Injection Moulding (IM).

View Article and Find Full Text PDF

Biological activities observed in living systems occur as the output of which nanometer-, submicrometer-, and micrometer-sized structures and tissues non-linearly and dynamically behave through chemical reaction networks, including the generation of various molecules and their assembly and disassembly. To understand the essence of the dynamic behavior in living systems, simpler artificial objects that exhibit cell-like non-linear phenomena have been recently constructed. However, most objects exhibiting cell-like dynamics have been found through trial-and-error experiments, and there are no strategies for designing them as molecular systems.

View Article and Find Full Text PDF

A polarization-independent dual-peak narrow-band filter is proposed and demonstrated theoretically and experimentally, which is realized by using a helical long-period fiber grating (HLPG) but with a period small down to tens of micrometers. Unlike those excessively tilted fiber gratings (Ex-TFGs) or the conventional long-period fiber gratings (LPGs) but with a small period down to tens of micrometers where the generated dual-peak pairs (DPPs) are all of the strong polarization-dependence, the DPPs obtained in this study are of the polarization-independent, which is the first time, to the best of our knowledge, that the underlying mechanism for generation of the polarization-independent DPPs in transmission spectrum of the helical small-period fiber grating (HSPFG) has been revealed both theoretically and experimentally.

View Article and Find Full Text PDF

In this paper, we study the propagation and time-evolution behavior of superfluorescence in an overdamped semiconductor ring microcavity. By introducing a re-coupling mechanism between the unidirectionally propagating superfluorescence and the cooperative exciton state with a specified Gaussian spatial distribution, we can compress the width of the photoluminescence (PL) pulse in both temporal and spatial scales. Using realistic parameters from perovskite superlattice materials, we observe that the maximum intensity increases twofold compared to the ordinary radiation behavior observed in planar microcavity systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!