Bloodless cannulation of the ascending aorta.

J Card Surg

Mid-Atlantic Heart Institute, Lancaster General Hospital, Pennsylvania 17603, USA.

Published: January 1998

Bloodless cannulation of the aorta can be accomplished easily. A full thickness stab wound prior to insertion of the cannula is unnecessary as the aorta's inner layers have little strength.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8191.1998.tb01059.xDOI Listing

Publication Analysis

Top Keywords

bloodless cannulation
8
cannulation ascending
4
ascending aorta
4
aorta bloodless
4
cannulation aorta
4
aorta accomplished
4
accomplished easily
4
easily full
4
full thickness
4
thickness stab
4

Similar Publications

Article Synopsis
  • The study compares two anticoagulation protocols used during intraoperative VA-ECMO support in double lung transplant patients from 2016 to 2023.
  • One protocol used a high-target activated clotting time (ACT) while the other used a low-dose heparin approach with a TXA infusion.
  • Results showed that the low heparin group had shorter surgery times and less need for blood products, with no significant differences in post-operative complications or severe primary graft dysfunction rates.
View Article and Find Full Text PDF

Over the previous 20 years, the use of extracorporeal membranous oxygenation (ECMO) as a bridge to durable left ventricular assist device (dLVAD) increased significantly. Additionally, emerging literature has demonstrated a protective effect of biventricular decompression while on ECMO, with one such strategy including a temporary LVAD and right ventricular assist device (RVAD). The complexity of these operations is increased by the frequency of re-sternotomies, which result in adhesions and difficult access to traditional cannulation sites.

View Article and Find Full Text PDF
Article Synopsis
  • - The report describes a rare instance of superior vena cava (SVC) syndrome in a 33-year-old female patient with a history of systemic lupus erythematosus and dependency on chronic hemodialysis, linked to an obstructive right subclavian dialysis catheter.
  • - Management was complicated by the patient’s severe anemia and a tension hemothorax, exacerbated by her refusal of blood transfusions due to her Jehovah's Witness beliefs.
  • - A multidisciplinary team utilized bloodless medical techniques, such as erythropoietin and iron infusions, along with surgical methods, highlighting the importance of respecting patient beliefs in challenging medical situations.
View Article and Find Full Text PDF

BACKGROUND Aortic dissection is rare after coronary artery bypass grafting (CABG). It is a potentially fatal complication of cardiac surgery. Reoperation may pose problems with thoracotomy, adhesiolysis, and myocardial protection.

View Article and Find Full Text PDF

: Minimally invasive cardiac surgery (MICS) has been developing since 1996. Peripheral cannulation is required to perform MICS, and good venous drainage and a bloodless field are crucial for the success of this procedure. We assessed the benefits of using a virtually wall-less cannula in comparison with the standard thin-wall cannula in clinical practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!