Relationship of circadian temperature and activity rhythms in two rodent species.

Physiol Behav

Department of Biological Sciences, University of South Carolina, Columbia 29208, USA.

Published: December 1998

Despite the large number of publications concerning circadian body temperature in rodents, relatively little is known about phase relationships of the body temperature cycle relative to daily locomotor rhythms. Phase angle differences between core body temperature and locomotor activity were determined by a group of overlapping methods for 14 hamsters and 11 chipmunks under constant light (LL) and entrained (LD) photo schedules. The study compared the onset of the body temperature cycle with three separate components of daily locomotor activity: the onset of wheel running, the onset of total activity in a standard wheel cage, and the onset of total activity in a restricted cage, respectively. The temperature cycle showed a pronounced phase lead over onset of wheel-running activity in all hamsters and in the majority of chipmunks, but the phase lead was reduced when total activity was considered. With activity restriction, the onset of temperature rise and activity onset concurred. The body temperature onset in some species may serve as a valid phase point for indirect measurement of circadian timing, but the potential artifact of masking by heat generated from muscular activity should be kept clearly in mind.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0031-9384(98)00187-5DOI Listing

Publication Analysis

Top Keywords

body temperature
20
temperature cycle
12
total activity
12
activity
10
temperature
8
daily locomotor
8
locomotor activity
8
onset
8
activity onset
8
onset total
8

Similar Publications

Objective: This study aimed to evaluate the effects of different cold acclimation strategies on exercise performance in male mice exposed to low-temperature environments.

Methods: Male mice were subjected to five distinct acclimation regimens over 8 weeks: immersion at 10 °C (10 °CI) or 20 °C (20 °CI), swimming at 10 °C (10 °CS), 20 °C (20 °CS), or 34 °C (34 °CS). During the first 2 weeks, the acclimation time progressively decreased from 30 min to 3 min per day, and the water temperatures were lowered from 34 °C to the target levels, followed by 6 weeks of consistent exposure.

View Article and Find Full Text PDF

Silicon carbide (SiC) metal oxide semiconductor field-effect transistors (MOSFETs) are a future trend in traction inverters in electric vehicles (EVs), and their thermal safety is crucial. Temperature-sensitive electrical parameters' (TSEPs) indirect detection normally requires additional circuits, which can interfere with the system and increase costs, thereby limiting applications. Therefore, there is still a lack of cost-effective and sensorless thermal monitoring techniques.

View Article and Find Full Text PDF

According to South Korea's Ministry of Employment and Labor, approximately 25,000 construction workers suffered from various injuries between 2015 and 2019. Additionally, about 500 fatalities occur annually, and multiple studies are being conducted to prevent these accidents and quickly identify their occurrence to secure the golden time for the injured. Recently, AI-based video analysis systems for detecting safety accidents have been introduced.

View Article and Find Full Text PDF

Heat Stroke Warning System Prototype for Athletes: A Pilot Study.

Sensors (Basel)

January 2025

Department of Sports Science and Sports Development, Faculty of Allied Health Sciences, Thammasat University, Pathumthani 12120, Thailand.

This research has developed a heat stroke warning system prototype for athletes utilizing the following sensors: DHT22, GY-906-BAA MLX90614, MAX30102. The device calculates the heat stroke risk and notifies users. The data is recorded, stored, displayed on a free-access website which graphs body temperature, ambient temperature, humidity, heart rate and heat stroke risk, and provides notifications for athletes engaged in outdoor activities.

View Article and Find Full Text PDF

: To compare tracheal temperature (T) with nasopharyngeal temperature (T) in patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). : T was measured using a thermistor in the cuff of an endotracheal tube and T was monitored using an esophageal stethoscope. Depending on the management of the CPB strategy, the operation was divided into four periods (pre-CPB, cooling, rewarming, and post-CPB).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!