The widespread use of central venous catheters in the treatment of pediatric patients has caused an increased incidence of complications. A rare, but potentially fatal complication occurs when the heart is perforated by the catheter tip causing a cardiac tamponade. This perforation of the heart generally is associated with the insertion procedure, but may also occur after some time because of displacement of the catheter tip. The authors present three cases in which the placement of a central venous catheter resulted in lethal cardiac tamponade. Proper positioning of the catheter tip in the superior vena cava and a high index of suspicion are essential in preventing this serious complication. Contrast-enhanced chest x-ray after insertion of the catheter must be performed to ascertain a correct position of the tip.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-3468(98)90296-2DOI Listing

Publication Analysis

Top Keywords

cardiac tamponade
12
central venous
12
venous catheters
8
catheter
5
tamponade rare
4
rare life-threatening
4
life-threatening complication
4
complication central
4
catheters children
4
children widespread
4

Similar Publications

Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).

View Article and Find Full Text PDF

Background: The guidelines recommend anticoagulation management with uninterrupted warfarin or direct thrombin inhibitors (DTIs) during the atrial fibrillation (AF) ablation periprocedural period.

Objectives: To clarify the Japanese real-world latest periprocedural anticoagulation management during AF ablation.

Methods: This multicenter observational study included 6232 consecutive AF patients (68.

View Article and Find Full Text PDF

Background: Transvenous pacemakers (TVP) and leadless pacemakers (LP) are two reliable permanent modalities for the treatment of heart rhythm disorders. Several observational studies explored the safety and efficacy of the two devices. The aim of this meta-analysis study is to present a comparative analysis of the safety of leadless versus transvenous pacemakers.

View Article and Find Full Text PDF

Catheter ablation procedure for symptomatic atrial fibrillation is an established treatment. Cardiac tamponade is one of the several complications associated with atrial fibrillation ablation. We present the case of a 60-year-old male with a past medical history of end-stage renal disease (ESRD) on hemodialysis, hypotension on midodrine, atrial fibrillation status post-ablation a week prior, and a cerebrovascular accident who presented to the emergency department with complaints of weakness, nausea, vomiting, confusion and some syncopal episodes for the past few days.

View Article and Find Full Text PDF

Background: Acute type A aortic dissection (ATAAD) has a high mortality, and acute aortic repair is the only curative treatment. In patients treated with factor Xa (FXa) inhibitors, the risk of severe disease-related complications such as cardiac tamponade and hemodynamic shock must be balanced against the potential for severe perioperative bleeding. The aim was to study intraoperative changes in plasma levels of the FXa inhibitor apixaban when using hemoadsorption during acute thoracic aortic repair.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!