AI Article Synopsis

Article Abstract

The issue of valve prosthesis-patient mismatch in small annular patients is still controversial. The hemodynamic function of bileaflet mechanical valves in the aortic position was examined using dobutamine-stress echocardiography. Forty-four patients were enrolled in the study and divided into 5 groups, according to prosthesis size, from 21 mm to 29 mm. The aortic peak pressure gradient (APG) increased significantly in all groups with dobutamine-stress and exceeded 50 mmHg in 83% of the 21-mm group, in 64% of the 23-mm group, and in 33% of the 25-mm group. The APG even exceeded 80 mmHg in 22% and 18% of the 21-mm and 23-mm groups, respectively. In these cases, the potential of 'valve prosthesis-patient mismatch' was considered. From the relationship between the APG and the prosthesis valve area index (VAI), 'critical VAIs' were found where patients were likely to enter the 'mismatch' status; that is, 1.22 and 1.77 cm2/m2, respectively, for the 5 and 10 microg/kg per min stages of dobutamine stress. This critical VAI range is useful in predicting the 'mismatch' patients preoperatively. Alternative procedures or prostheses should then be selected for them.

Download full-text PDF

Source
http://dx.doi.org/10.1253/jcj.62.817DOI Listing

Publication Analysis

Top Keywords

bileaflet mechanical
8
aortic position
8
dobutamine-stress echocardiography
8
exceeded mmhg
8
functional evaluation
4
evaluation bileaflet
4
valve
4
mechanical valve
4
valve aortic
4
position dobutamine-stress
4

Similar Publications

Inheritance of Imaging Parameters of Arrhythmic Risk in Mitral Valve Prolapse: A Pedigree Study.

Circ Cardiovasc Imaging

January 2025

Division of Cardiology, Department of Medicine, University of California, San Francisco (L.C., S.D., D.B., J.J.T., Q.F., L.T., A.H.R., R.J., S.H., H.H.H., Z.H.T., N.B.S., F.N.D.).

Background: A subset of patients with mitral valve prolapse (MVP), a highly heritable condition, experience sudden cardiac arrest (SCA) or sudden cardiac death (SCD). However, the inheritance of phenotypic imaging features of arrhythmic MVP remains unknown.

Methods: We recruited 23 MVP probands, including 9 with SCA/SCD and 14 with frequent/complex ventricular ectopy.

View Article and Find Full Text PDF

This study evaluates the efficacy of annuloplasty repair as a standalone procedure for treating bileaflet mitral valve prolapse with mitral regurgitation (MR). Various flexible ring bands for MR of different severities were compared to assess their biomechanical impact and treatment outcomes. Computational beating heart models, based on the Living Heart Human Model, were utilized to simulate annuloplasty repairs.

View Article and Find Full Text PDF

Objective: The aim of this study was to investigate outcomes after endovascular aortic arch repair in patients with a mechanical aortic valve where the valve needs to be crossed.

Methods: An international, multicentre, retrospective observational study was undertaken including all consecutive patients who underwent endovascular arch repair with mechanical aortic valve crossing.

Results: From March 2020 to August 2023, 12 patients were included in the study (median age 55 years, interquartile range 45, 67 years; 58% male).

View Article and Find Full Text PDF

The assessment and reduction of haemolysis within mechanical circulatory support (MCS) remains a concern with regard to device safety and regulatory approval. Numerical methods for predicting haemolysis have typically been applied to rotary MCS devices and the extent to which these methods apply to positive-displacement MCS is unclear. The aim of this study was to evaluate the suitability of these methods for assessing haemolysis in positive-displacement blood pumps.

View Article and Find Full Text PDF

The hemodynamic performance of different prosthetic heart valves is difficult to compare among studies due to a variety of test conditions and experimental techniques. Existing studies are typically limited to one family of valves (biological or mechanical) and testing conditions of 5l/min and often lack sufficient spatial resolution. To address these limitations, a pulse duplicator with a multi-view imaging system (Tomo-PIV) was employed to investigate the three-dimensional flow field in the aortic root of three different valves: a tri-leaflet mechanical heart valve (TRIFLO, Novostia), a bi-leaflet mechanical heart valve (On-X, Artivion), and a biological heart valve (Perimount, Edwards Lifesciences).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!