We studied fixation of displaced femoral neck fractures prospectively in a randomized multicenter study, comparing 2 Olmed screws, 2 Tronzo screws and 3 Ullevaal hip screws. The study population consisted of 482 women and 125 men, of whom 432 women and 100 men were older than 65 years of age. Their median age was 80 (54-97) years. Despite agreement on criteria, the rates of reoperations for pain and failure--salvage (prosthesis replacement) and other reoperations (removal of implant)--differed significantly between the 3 hospitals regardless of type of fixation. In total, the percentages of salvage operations were: Olmed screw 17/175, Tronzo 17/130 and Ullevaal screw 11/302 (n.s.); the percentages of other reoperations were 11, 6 and 13, respectively (n.s.). In the whole series, the 2-year rate of salvage operations was 14%. No differences between the implants were found in patients older than 65 years of age. We conclude that an agreed, common definition of a hard end-point (reoperation) does not ensure comparability of results, because of differences in clinical decision making.

Download full-text PDF

Source
http://dx.doi.org/10.3109/17453679808997779DOI Listing

Publication Analysis

Top Keywords

fixation displaced
8
displaced femoral
8
femoral neck
8
neck fractures
8
older years
8
years age
8
salvage operations
8
biases randomized
4
randomized comparison
4
comparison three
4

Similar Publications

Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).

Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.

View Article and Find Full Text PDF

Reliability of unicortical plate fixation for metacarpal shaft fractures: A preliminary clinical report with short-term follow-up.

Ann Chir Plast Esthet

January 2025

Department of Plastic and Reconstructive Surgery, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Republic of Korea.

Background: Unicortical plate fixation offers several theoretical advantages in the treatment of metacarpal shaft fractures compared to bicortical fixation. This approach avoids the potential hazard of excessive drilling into the volar cortex, thus minimizing damage to surrounding soft tissues and helping prevent complications related to improperly sized screws. These benefits prompted our team to conduct a preliminary clinical study to investigate the effectiveness and safety of this approach.

View Article and Find Full Text PDF

Sternal fractures resulting from blunt chest trauma often present unique surgical challenges. While conservative management is common, cases with significant displacement, delayed union, or painful dyspnea may require surgical intervention to improve structural stability and relieve symptoms. Here, we report the case of a 46-year-old man who sustained a displaced sternal fracture in a motor vehicle accident.

View Article and Find Full Text PDF

Background: Consequences of osteochondral fractures associated with patellar dislocation can be severe for younger patients. Precise 3-dimensional characterization of fracture location, size, frequency, and radiographic associations remain undefined in this population.

Purpose: (1) To define the topographic characteristics of osteochondral fractures in pediatric and adolescent patients with first-time patellar dislocations and (2) to determine the relationship between these characteristics and radiographic and patient factors.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!