Purpose: To evaluate the efficacy of primary stenting for complex atherosclerotic plaques in aortic and iliac stenoses that are not amenable to balloon angioplasty alone.
Methods: Nineteen patients with complex atherosclerotic plaques were treated with a Palmaz stent (n = 19), Wallstent (n = 1), Strecker stent (n = 1), or Memotherm stent (n = 1). A total of 22 stenoses presenting with complex plaque morphology including ulcerated plaques, ulcerated plaques with focal aneurysms, plaques with heavy calcification, severely eccentric plaques, plaques with overhanging edge, and plaques with spontaneous dissection were stented. The lesions were in the aorta (n = 1), common iliac artery (n = 19), or external iliac artery (n = 2).
Results: Immediate angiography after stent placement revealed restoration of patency of the stented segment. Focal aneurysms and ulcerated areas were occluded in the follow-up angiographies obtained 4-12 weeks after the procedure. In one case with poor distal runoff and multiple complex lesions of the iliac artery, subacute occlusion occurred. Clinical and angiographic follow-up (3-46 months) revealed patency of all other stented segments.
Conclusion: Primary stenting is an effective and reliable approach for complex plaques in stenoses. Patency of the arterial segment with a smooth lumen can be created without the risk of acute complications such as distal embolization, dissection, or occlusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s002709900285 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
State Key Laboratory of Frigid Zone Cardiovascular Diseases, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Background: Biodegradable polymer stents may reduce the risk of neoatherosclerosis and stent thrombosis. Limited data is available for biodegradable polymer sirolimus-eluting stent (BP-SES) and durable polymer drug-eluting stents (DP-EES) in chronic total occlusions (CTO).
Aim: This study was to evaluate healing patterns of BP-SES versus DP-EES in CTO at 3 and 13 months based on optical coherence tomography (OCT).
J Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, AZ Sint Blasius, Dendermonde, Belgium.
Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.
Methods: Seventy patients and 133 lesions were included at six Belgian institutions.
Circ Cardiovasc Interv
January 2025
Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (D.M.F.v.d.B., E.M.P., E.W., D.C., E.M., B.F., M.V., J.D., K.A.).
Background: Geographic stent-ostium mismatch is an important predictor of target lesion failure after percutaneous coronary intervention of an aorto-ostial right coronary artery lesion. Optimal visualization of the aorto-ostial plane is crucial for precise stent implantation at the level of the ostium. This study investigates whether preprocedural 3-dimensional computed tomography (3DCT), with determination of the optimal viewing angle, would allow for more precise stent implantation and reduce procedure time, contrast, and radiation dose.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Prague Lung Transplant Program, 3rd Department of Surgery, First Faculty of Medicine, Charles University and Motol University Hospital, Prague, Czech Republic.
Scoliotic deformity represents a serious spinal disorder that influences the locomotive and cardiopulmonary systems. Some patients with severe scoliosis and end-stage lung disease are therefore denied lung transplantation. In patients with scoliosis considering lung transplantation, size match, straight back syndrome, delayed chest closure and bronchial stenosis are key issues clinicians should evaluate.
View Article and Find Full Text PDFJ Glaucoma
January 2025
Wills Eye Hospital Glaucoma Service, Philadelphia, PA, USA.
Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).
Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.
Methods: Multicenter, real-world, retrospective study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!