1. The effects of the divalent cations Ca2+, Mg2+ and Ni2+ on unitary Na+ currents through receptor-regulated non-selective cation channels were studied in inside-out and cell-attached patches from rat adrenal zona glomerulosa cells. 2. External Ca2+ caused a concentration-dependent and voltage-independent inhibition of inward Na+ current, exhibiting an IC50 of 1.4 mM. The channel was also Ca2+ permeant and external Ca2+ shifted the reversal potential as expected for a channel exhibiting a constant Ca2+ : Na+ permeability ratio near to 4. 3. External and internal 2 mM Mg2+ caused voltage-dependent inhibition of inward and outward Na+ current, respectively. Modelling Mg2+ as an impermeant fast open channel blocker indicated that external Mg2+ blocked the pore at a single site exhibiting a zero voltage Kd of 5.1 mM for Mg2+ and located 19 % of the distance through the transmembrane electric field from the external surface. Internal Mg2+ blocked the pore at a second site exhibiting a Kd of 1.7 mM for Mg2+ and located 36% of the distance through the transmembrane electric field from the cytosolic surface. 4. External Ni2+ caused a voltage- and concentration-dependent slow blockade of inward Na+ current. Modelling Ni2+ as an impermeant slow open channel blocker indicated that Ni2+ blocked the pore at a single site exhibiting a Kd of 1.09 mM for Ni2+ and located 13.7% of the distance through the transmembrane electric field from the external surface. 5. External 2 mM Mg2+ increased the Kd for external Ni2+ binding to 1.27 mM, consistent with competition for a single binding site. Changing ionic strength did not substantially affect Ni2+ blockade indicating the absence of surface potential under physiological ionic conditions. 6. It is concluded that at least two divalent cation binding sites, separated by a high free energy barrier (the selectivity filter), are located in the pore and contribute to Ca2+ selectivity and permeability of the channel.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2269083PMC
http://dx.doi.org/10.1111/j.1469-7793.1999.397ae.xDOI Listing

Publication Analysis

Top Keywords

na+ current
12
blocked pore
12
site exhibiting
12
distance transmembrane
12
transmembrane electric
12
electric field
12
external
9
divalent cation
8
non-selective cation
8
cation channels
8

Similar Publications

High-Performance Oxide Crystal BaTeWO X-ray Detector with High Stability, Low Detection Limit, and Ultralow Dark Current Drift.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Crystal Materials and Institute of Crystal Materials, Shandong University, Jinan 250100, China.

X-ray detection materials and devices have received widespread attention due to their irreplaceable role in the medical, industrial, and military fields. In this paper, BaTeWO (BTW) crystal containing lone pairs of electrons with large atomic numbers and high density is reported as a new type of oxide crystal X-ray detection material. The anisotropic X-ray detection performance of the BTW single crystal (SC) is systematically studied.

View Article and Find Full Text PDF

On the substrate turnover rate of NBCe1 and AE1 SLC4 transporters: structure-function considerations.

Front Physiol

January 2025

Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States.

A transport protein's turnover rate (TOR) is the maximum rate of substrate translocation under saturating conditions. This parameter represents the number of transporting events per transporter molecule (assuming a single transport site) per second (s). From this standpoint, a transporter's TOR is similar to an enzyme's catalytic constant.

View Article and Find Full Text PDF

Background: Acute-on-chronic liver failure (ACLF) is a life threatening disease. This study seeks to identify factors that contribute to greater financial burden in ACLF.

Methods: In total, 55 patients were included.

View Article and Find Full Text PDF

Potency and quantitative risk assessment are essential for determining safe concentrations for the formulation of potential skin sensitizers into consumer products. Several new approach methodologies (NAMs) for skin sensitization hazard assessment have been developed, validated, and adopted in OECD test guidelines. However, work is ongoing to develop NAMs for predicting skin sensitization potency on a quantitative scale for use as a point of departure (POD) in next-generation risk assessment (NGRA).

View Article and Find Full Text PDF

(Pro)renin receptor (PRR) contains overlapping cleavage site for site-1 protease (S1P) and furin for generation of soluble PRR (sPRR). Although S1P-mediated cleavage mediates the release of sPRR, the functional implication of furin-mediated cleavage is unclear. Here we tested whether furin-mediated cleavage was required for the activity of sPRR in activating ENaC in cultured M-1 cells.

View Article and Find Full Text PDF