We considered the theoretical differences between the normal relationships of coronary blood flow and perfusion pressure in the working heart and those obtained with continuous, steady-flow perfusion by a roller pump during aortic valve replacement. Steady pump perfusion should deliver less blood flow to the endocardium because: 1. For the same mean artery perfusion pressure, the average coronary blood flow is less with constant-flow pump perfusion. 2. With constant pump perfusion, pressure would be excessively high during systole, and during diastole it would be significantly lower than the mean perfusion pressure. Instantaneous pressure and flow were measured in the left coronary artery in 8 patients undergoing aortic valve replacement, employing either roller pump perfusion or a gravity flow system to provide a steady pressure source. Although we did not attempt to demonstrate improved endocardial flow, the mean left coronary flow was always greater with gravity perfusion (297 versus 153 ml/min), lending support to the theoretically proposed differences between the two perfusion methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0003-4975(10)64966-1 | DOI Listing |
Surg Endosc
January 2025
Clinica Chirurgica, Department of Experimental and Clinical Medicine, Section of Surgical Sciences, Polytechnic University of Marche, Ancona, Italy.
Introduction: Altered vascular microcirculation is recognized as a risk factor for anastomotic leakage (AL) in colorectal surgery. However, few studies evaluated its impact on AL using different devices, with heterogeneous results. The present study reported the initial experience measuring gut microcirculatory density and flow with the aid of incidence dark-field (IDF) videomicroscopy (Cytocam, Braedius, Amsterdam, The Netherlands) comparing its operative outcome using a propensity score matching (PSM) model based on age, gender, and Charlson Comorbidity Index (CCI).
View Article and Find Full Text PDFArtif Organs
January 2025
Division of Life Science and Medicine, School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, China.
Background: Membrane oxygenators facilitate extracorporeal gas exchange, necessitating the monitoring of blood gas. Recent advances in normothermic machine perfusion (NMP) for ex vivo liver offer solutions to the shortage of donor liver. However, maintaining physiological blood gas levels during prolonged NMP is complex and costly.
View Article and Find Full Text PDFBackground: Intrabdominal pressure (IAP) is an important parameter. Elevated IAP can reduce visceral perfusion, lead to intraabdominal hypertension, and result in life-threatening abdominal compartment syndrome. While ingestible capsular devices have been used for various abdominal diagnoses, their application in continuous IAP monitoring remains unproven.
View Article and Find Full Text PDFIntensive Crit Care Nurs
January 2025
Department of Intensive Care Medicine, Hospital Universitario de La Princesa, Madrid, Spain; Centro de investigación en red CIBERES de enfermedades respiratorias, Instituto de Salud, Carlos III, Madrid, Spain. Electronic address:
Objectives: To analyse the effects on respiratory function, lung volume and the regional distribution of ventilation and perfusion of routine postural repositioning in mechanically ventilated critically ill patients.
Methods: Prospective descriptive physiological study. We evaluated gas-exchange, lung mechanics, and Electrical Impedance Tomography (EIT) determined end-expiratory lung impedance and regional ventilation and perfusion distribution in five body positions: supine-baseline (S1); first lateralisation at 30° (L1); second supine position (S2), second contralateral lateralisation (L2) and third final supine position (S3).
Br J Anaesth
January 2025
Department of Anaesthesia, Rabin Medical Centre, Beilinson Hospital, Petach Tikva, Israel; Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel. Electronic address: