A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative evaluation of four different infusion rates of ropivacaine (2 mg/mL) for epidural labor analgesia. | LitMetric

Background And Objectives: Previous studies have reported comparable efficacy for ropivacaine and bupivacaine when used for labor analgesia at concentrations of 2.5 mg/mL. In this multicenter study, we assessed ropivacaine at the commercially available concentration of 2 mg/mL (0.2%) for labor pain management.

Methods: After Institutional Review Board approval and informed consent, 128 women at term were randomly assigned to receive ropivacaine at one of the four infusion rates via a lumbar epidural catheter. Analgesia was initiated with a 5-mL test dose, followed by injections of 5-15 mL of 2 mg/mL ropivacaine. The continuous infusion was then started at 4, 6, 8, or 10 rmL/hour. Rescue analgesia was provided with 5-mL "top-up" injections as necessary to provide maternal comfort. Pain relief was assessed by using a visual analog pain scale (VAPS) and motor block was assessed by using a modified Bromage scale.

Results: All infusion regimens effectively decreased VAPS, and most patients in all groups had minimal or no motor block at the end of the first stage of labor. Mean total number of the top-up injections required per patient were 3, 2, 1.5, and 1.4, respectively, in the 4, 6, 8, and 10-mL/hour groups (P < .05, 4 mL/hour vs. all other groups). Despite receiving more total bolus dosages, the 4-mL/hour group had less motor block in the lower extremities (P < .05). Apgar scores and neurological adaptive capacity scores were similar for all groups.

Conclusions: The 2 mg/mL of ropivacaine produces satisfactory labor analgesia at epidural infusion rates of 4, 6, 8, and 10 mL/hour, provided supplemental bolus dosages are available. Clinically, a rate of 6 mL/hour may be the lowest effective rate that provides the best combination of pain relief, motor block, and rebolusing, although rates of 8 and 10 mL/hour produced similar results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1098-7339(98)90079-7DOI Listing

Publication Analysis

Top Keywords

motor block
16
infusion rates
12
labor analgesia
12
mg/ml ropivacaine
8
pain relief
8
bolus dosages
8
rates ml/hour
8
ropivacaine
6
infusion
5
mg/ml
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!