AI Article Synopsis

Article Abstract

By utilizing achievements and results of two previous concerted research projects on magnetic resonance imaging and spectroscopy (MRS), the EU BIOMED 1 Concerted Action on "Cancer and brain disease characterization and therapy assessment by quantitative MRS" was specifically aimed at: 1) developing at a multicentre level harmonized methodologies and protocols for quantitative and reproducible MRS measurements, as a basis for validating these procedures in well controlled clinical and experimental conditions; and 2) providing multicentre critical reviews on the present understanding of the significance of MRS parameters as possible new markers of diagnosis, prognosis and response to therapy. The programme comprised the following main areas of collaborative research and multicentre evaluation: a) development of methods and protocols for quality assessment, calibration and absolute metabolite quantification in in vivo localized, volume-selective MRS; b) design and validation of a new method for assessing localization performance in spectroscopic imaging (MRSI); c) interlaboratory comparison of different methods of signal processing and data analysis, for improving signal quantification in vivo and in vitro MRS spectra; d) quality assessment of high resolution MRS analyses of biological fluids; e) protocol for assembling a pilot data base of MR spectra of tumour extracts for pattern recognition analysis; f) multicentre review on evaluation of the significance of MRS parameters in monitoring lipid metabolism and function in cancer; and g) multicentre review on evaluation of drug pharmacokinetics and metabolism using MRS. The main results and conclusions of four multi-centre trials on items (a), (b) and (c), which involved 24 teams, are reported in the accompanying papers of this series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0730-725x(98)00117-9DOI Listing

Publication Analysis

Top Keywords

quantification vivo
12
absolute metabolite
8
metabolite quantification
8
concerted action
8
significance parameters
8
quality assessment
8
multicentre review
8
review evaluation
8
multicentre
5
vivo nmr
4

Similar Publications

Proton magnetic resonance spectroscopy (MRS) offers a non-invasive, repeatable, and reproducible method for in vivo metabolite profiling of the brain and other tissues. However, metabolite fingerprinting by MRS requires high signal-to-noise ratios for accurate metabolite quantification, which has traditionally been limited to large volumes of interest, compromising spatial fidelity. In this study, we introduce a new optimized pipeline that combines LASER MRS acquisition at 11.

View Article and Find Full Text PDF

Purpose: This study proposes a novel, contrast-free Magnetic Resonance Fingerprinting (MRF) method using balanced Steady-State Free Precession (bSSFP) sequences for the quantification of cerebral blood volume (CBV), vessel radius (R), and relaxometry parameters (T , T , T *) in the brain.

Methods: The technique leverages the sensitivity of bSSFP sequences to intra-voxel frequency distributions in both transient and steady-state regimes. A dictionary-matching process is employed, using simulations of realistic mouse microvascular networks to generate the MRF dictionary.

View Article and Find Full Text PDF

Corticocortical (CC) projections in the visual system facilitate hierarchical processing of sensory information. In addition to direct CC connections, indirect cortico-thalamo-cortical (CTC) pathways through the pulvinar nucleus of the thalamus can relay sensory signals and mediate cortical interactions according to behavioral demands. While the pulvinar connects extensively to the entire visual cortex, it is unknown whether transthalamic pathways link all cortical areas or whether they follow systematic organizational rules.

View Article and Find Full Text PDF

Natural killer T cells (NKTs) are a promising platform for cancer immunotherapy, but few genes involved in regulation of NKT therapeutic activity have been identified. To find regulators of NKT functional fitness, we developed a CRISPR/Cas9-based mutagenesis screen that employs a guide RNA (gRNA) library targeting 1,118 immune-related genes. Unmodified NKTs and NKTs expressing a GD2-specific chimeric antigen receptor (GD2.

View Article and Find Full Text PDF

Recombinant adeno-associated virus (rAAV) has emerged as the vector of choice for in vivo gene delivery, with numerous clinical trials underway for the treatment of various human diseases. Utilizing rAAV in gene therapy requires a highly precise quantification method to determine the viral genome titer and further establish the optimal therapeutic dosage for a rAAV product. The conventional single-channel droplet digital PCR (1D ddPCR) method offers only partial information regarding the viral vector genome titer, lacking insights into its integrity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!